                                                                                                                                                                                         “Undefined Use”
                                                                                                                                                    Staged Extension & Refurbishment of Existing RSL Club
                                                                                                                                                                      5 Memorial Ave, Tewantin QLD 4565
                                                                                                                                                                 Lot 3 on T16319 and Lot 10 on SP273411

change of paving material or fencing, rather than locking the   storage areas and the kerbside is—
area.                                                           a) for Multiple housing Type 3 – 40m;
                                                                b) for other uses – 70m; and
                                                                S3.4 Pathways used to transport bins—
                                                                a) have a maximum grade of 1:15; and
                                                                b) are free of steps, stairs or other impediments; AND
                                                                S4.1 Waste storage areas are—
                                                                a) integrated with the building design, where possible;
                                                                b) setback a minimum of 2m from side and rear property
                                                                boundaries;
                                                                c) screened so that bins are not visible from neighbouring
                                                                properties or passing vehicular and pedestrian traffic; and
                                                                d) not located directly adjacent to dwelling units on the site on
                                                                neighbouring properties; AND
                                                                S5.1 Waste storage areas are constructed of impermeable,
                                                                durable and non-textured materials and surfaces so that they
                                                                are easily cleaned; AND
                                                                S5.2 A minimum distance of 0.5m2 distance is provided
                                                                between and around waste storage bins to allow for
                                                                manoeuvring and washing of bins. AND
                                                                S6.1 No solution provided.
Water management for waste storage areas                        S7.1 The waste storage area —                                       Complies with the Possible Solutions – The proposed
O7 Waste storage areas are designed to contain and              a) is bunded and graded so that washwater and bin leakage           waste storage areas include design measures to ensure
appropriately dispose of leakage from bins and wastewater       are drained to the sewer or an on-site effluent disposal            washwater and bin leakage is contained and drained to a
from bin washing.                                               system via a gully within the storage area;                         sewer line.
                                                                b) has a bund wall with a maximum height of 100mm;                  The refuse area is located undercover and is screened to
                                                                c) is serviced by a conveniently located hosecock and               maintain visual amenity. Council is directed to Appendix B –
                                                                backflow prevention device, and connected to a water supply;        Architectural Plans for further details.
                                                                and
                                                                d) is roofed or otherwise covered if the storage area is—
                                                                i) more than 1m2; or
                                                                ii) storing wet waste; or
                                                                iii) storing other waste with a high potential to cause pollution
                                                                if washed or leaked from the bins, including waste oil or

July 2016                                                                                                         Page | 54

Log in to download the original (MCU16_0079 Town Planning Report.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.