Original source · versioned page text
Appendix D - Residential use codes
Attached to the e-mail Multiple Housing Type 3 Retirement & Special Needs (48 units) - MCU18/0009.
Annexure D - Residential Use Code Proposed Material Change of Use of Premises for a Multiple Housing - Type 3 Retirement and Special Needs at 186 Cooroy Noosa Road, Tewantin described as Lot 2 on RP177554 14.51 Specific Outcomes, probable solutions and acceptable solutions for the Residential Uses Code Table -1 — For All Residential Uses column 1 column 2 Column 3 Specific Outcomes Probable solutions (if code assessable) Compliance Effects of use Electricity supply infrastructure O1 The development does not adversely S1.1 No solution provided Complies impact on existing or future electricity supply infrastructure; AND O2 All uses and works maintain an S2.1 Development for uses adjacent to or Not applicable adequate safe distance from electrical within 50m of an existing electricity infrastructure including substations, substation incorporates noise attenuation overhead powerlines, power poles and measures to mitigate noise impacts; AND transformers. S2.2 Buildings and structures (including Complies swimming pools, sheds, tennis courts or outbuildings) are not constructed under overhead electricity transmission lines, or within electricity easements; AND S2.3 A minimum separation distance is Not applicable maintained from the electricity transmission line to the closest boundary of habitable buildings and child activity areas, as follows— a) 20m for transmission lines up to 132kV; b) 30m for transmission lines between 133kV and 275kV; and c) 40m for transmission lines greater than 275kV. Water supply and conservation O3 On-site water storage is designed and S3.1 & S4.1 For a Class 1 building other Not applicable operated to support the efficient use of water; than a Detached house , outside a AND reticulated water service area, a rainwater O4 On-site water storage is adequate for tank is to be installed with the following occupants every day use and fire fighting minimum storage capacities— purpose a) Where no more than 3 bedrooms – 45,000 litres; or b) Where more than 3 bedrooms – 60,000 litres; AND c) There is to be on the lot a dam, swimming pool or water tank accessible for use by the fire brigade that contains at least 5,000 litres of water. Erosion and sediment control O5 Development does not cause erosion No solution provided. Complies - Proposal will comply with or result in transport of sediments off-site. relevant Council policies and standards. Stormwater Management Plan included as part of application. Amenity and Built form Safety and security O6 For Multiple Housing Types 2, 3 and S6.1 The building entrance is clearly Complies – Site fully fenced for security and 4, buildings and outdoor spaces are identifiable and visible from the street, safety of residents. Controlled points of designed to protect the personal security and footpath and driveway; pedestrian and vehicular access to and safety of residents by allowing for natural AND through the site are provided. surveillance S6.2 The internal path network has clear sightlines to the dwelling entry and street Visitor carparking at front of site. access points; AND Clear pathways throughout site. S6.3 Visitors have direct access to the entrance without passing through private outdoor living areas. Page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original