Council archive · source document
0015CE08.001
Text sections not matched to the original PDF pages. See original document to check page numbers.
a ‘Foundation Maintenance and Owners Responsibilities
Trees and dense shrubs must be kept well away from the building. In alt types of soil conditions, if an
automatic watering system irrigates within 2.5 meters of a footing, instability problems may occur. Water
should not be allowed to pond on the ground near the building.
Definitions:
Controlled Fill - Man placed soil which has sufficient bearing to support a structure according to AS
2870-1996. Fill certified at Level 1 according to AS 3798 is controiled fill. ..
; Partially Controlled - Man placed soil which appears to have been compacted under controlled
conditions, but as the time of preparing this report, no compaction certificate suitable for compliance to
-Level 1 of AS 3798-1996 had been presented. CO
‘Uncontrolled Fill — Man placed soil (overlying the natural soils) which is not adequate to support a
‘normally loaded footing or floor slab.
oO ‘Unexcavatable Rock — Strong material including shaley material and strongly cemented sand or gravel
that does not soften in water or collapse under the combination of loading and wetting. Material that
. cannot readily be excavated by a backhoe may be taken to be rock.
Excavatable Rock — A rock-like material which does not shrink or sweil with changes in soil moisture, but
is readily excavatable with a conventional backhoe. . -
Load Bearing Wall - in our design work a load bearing wall is defined as any wall imposing on the
. footing a service load greater than 10kN/m. A load bearing wall will normally be supported by a slab
, thickening or footing in our slab designs.
Natural (Strata) — Refers to soil that is neither fill or imported material but one that is in its original
undisturbed state and position. ot
Gravel - Coarse soil particles, larger than sand size, but less than 60mm in diameter.
. Cobbles - Rocks greater than 60mm in diameter but less than 600mm in diameter. .
Boulders — Rocks larger than 600mm in diameter.
te ‘NOTE : The information contained herein has been compiled following our field and laboratory
testing, accepted engineering theory and discussions with, and information supplied by our
client, whom is noted at the head of this report. We offer no warranty for the use of this report by
other parties without prior written consent from this office.
. forandonbehalf
- _ $CG CONSULTING ENGINEERS
SCG CONSULTING ENGINEERS . 7 SCG Ref: 16078(S) ;See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015CE08.001.pdfRelated documentPublic source context ↗
06/1101 - Application for Op Works 18 Weyba St [As Published]Related documentApplication case desk ↗
About this file
- File size
- 702 KB (small file)
- File type
No other editions are linked here.