                 24.    The full length of the Peregian Esplanade frontage of the development site shall be
                        upgraded by providing kerb & channel. The kerb and channel shall be extended to the
                        existing Council catchpit located approximately 7 metres to the north of the site. The
                        alignment of the kerb and channel and any required modifications or improvements to
                        the existing catch pit shall be at the direction of Council at the time of engineering design.
                        All associated and ancillary work including pavement correction to the existing
                        pavement, drainage works, modification of the footpath, and adjustments to the existing
                        infrastructure shall be undertaken as part of these works.
                        In this regard, plans detailing this work shall be prepared and submitted to Council for
                        approval prior to obtaining a Development Permit for Operational Works.
                 25.    All paths, driveways and parking areas must be designed and constructed to ensure
                        pedestrian safety using non-slip materials, to produce an evenly graded surface finish,
                        and to be in accordance with the Disability Discrimination Act 1992 and Australian
                        Standard 1428.1 Design for Access & Mobility.
                 26.    All redundant vehicular crossings to the site must be removed and replaced by kerb &
                        channel, footpath paving and landscaping such as trees and grasses in accordance with
                        Council’s Standard specifications prior to commencement of the use permitted by this
                        permit.
                        Roof Water & Stormwater Drainage
                 27.    Roof runoff from any dwelling must be directed to a rainwater storage system or tank
                        that is installed to ensure water from the rainwater storage system or tank is used for
                        external uses (such as watering gardens, irrigation, ornamental ponds, water features,
                        topping-up swimming pools, outdoor cleaning, etc) and for internal (ground floor) use in
                        washing machine cold taps and toilet cisterns. All rainwater tanks are to be designed
                        and installed in accordance with the Queensland Development Code (QDC) current at
                        the time of building approval, and must be part of the plumbing application for approval.
                        The location and capacity of the tanks must be clearly shown on the plans submitted for
                        Building Works and Operational Works approval and any overflow must be directed to
                        the stormwater drainage system.
                 28.    All stormwater drainage (including roof water overflow from the rainwater storage
                        system) must be collected and discharged so there is no net increase in stormwater
                        runoff from the site. Stormwater drainage permitted to drain from the site must be
                        discharged to Council’s existing drainage structures in Peregian Esplanade. Plans of
                        the drainage design must be prepared by a Registered Professional Civil Engineer and
                        submitted to Council prior to obtaining a Development Permit for Operational Works.
                 29.    Stormwater runoff from the proposed carparking areas and driveway must be directed
                        to the stormwater drainage system.
                 30.    All site stormwater drainage must be by means of a gravity system.
                        Earthworks
                 31.    Filling works required on site must be carried out in accordance with Council’s Planning
                        Scheme Policy PSP5 – Engineering Design Standards, so as not to cause the additional
                        ponding of water on any adjoining lands or the blockage of, or interference with, any
                        natural watercourses.
                 32.    Earthworks carried out on site must not affect the structural integrity of any of the existing
                        fences or structures that border the development site. Fences that are affected must be
                        replaced prior to the Building Certifier issuing the Certificate of Classification. In this
                        regard any fences to be replaced must be clearly shown on the plans submitted for
                        Operational Works approval.
                        Site Stability




                                                                                                           Page 6 of 13
Document Set ID: 24928702
Version: 6, Version Date: 09/07/2026

Used in these records

About this file

File size
16.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appeal 26-042 - Lodgement Documents.pdf · 16.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.