STORMFILTER DESIGN TABLE
Ø2250 · STORMFILTER TREATMENT CAPACITY VARIES BY NUMBER OF FILTER CARTRIDGES INSTALLED.
· THE STANDARD CONFIGURATION IS SHOWN. ACTUAL CONFIGURATION OF THE SPECIFIED STRUCTURE(S) PER CERTIFYING
Ø2470 ENGINEER WILL BE SHOWN ON SUBMITTAL DRAWING(S).
· FILTER CARTRIDGES SHALL BE MEDIA-FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF-CLEANING. RADIAL
MEDIA DEPTH SHALL BE 178mm.
CARTRIDGE NAME / SIPHON HEIGHT (mm) 690 460 310
A
CARTRIDGE PHYSICAL HEIGHT (mm) 840 600 600
TYPICAL WEIR HEIGHT [H] (mm) 920 690 540
CARTRIDGE FLOW RATE FOR ZPG MEDIA (L/s) 1.6 1.1 0.7
INLET ANGLE TO SUIT
SITE REQUIREMENTS CARTRIDGE FLOW RATE FOR PSORB MEDIA (L/s) 0.9 0.46 0.39
SITE SPECIFIC
A DATA REQUIREMENTS
STRUCTURE ID [ ]
PHYSICAL HEIGHT
NUMBER OF CARTRIDGES REQ'D 7
SIPHON HEIGHT
SIPHON HEIGHT (310 / 460 / 690) [ ]
STORMFILTER
CARTRIDGE
MEDIA TYPE (ZPG / PSORB) [ ]
FILTRATION UNIT WATER QUALITY FLOW RATE (L/S) [ ]
HYDRAULIC CAPACITY (L/S) 90
FALSE FLOOR
PIPE DATA: I.L. MATERIAL DIAMETER
ACCESS COVER INLET PIPE #1 [ ][ ][ ]
PIT BASE
INLET PIPE #2 [ ][ ][ ]
STORMFILTER INLET PIPE #3 [ ][ ][ ]
PLAN CARTRIDGE DETAIL OUTLET PIPE [ ][ ][ ]
PRECAST MANHOLE WEIGHT 6500kg
CONSTRUCTION
PRECAST LID WEIGHT 2000kg
900 SQUARE CAST-IRON SOLID TOP
ACCESS COVER SUPPLIED LOOSE GENERAL NOTES
1. PRECAST STRUCTURE SUPPLIED WITH CORE HOLES TO SUIT OUTER DIAMETER OF NOMINATED PIPE SIZE / MATERIAL.
CONTRACTOR TO SEAL RISER OR SIMILAR IF REQUIRED 2. PRECAST STRUCTURE SHALL MEET W80 WHEEL LOAD RATING ASSUMING A MAXIMUM EARTH COVER OF 2.0m AND A
AS REQUIRED (BY OTHERS) GROUND WATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. CERTIFYING ENGINEER TO
CONFIRM ACTUAL GROUNDWATER ELEVATION. PRECAST STRUCTURE SHALL BE IN ACCORDANCE WITH AS3600.
200
3. IF THE PEAK FLOW RATE, AS DETERMINED BY THE SITE CERTIFYING ENGINEER, EXCEEDS THE PEAK HYDRAULIC
CAPACITY OF THE SYSTEM, AN UPSTREAM BYPASS STRUCTURE IS REQUIRED.
INLET INVERT MINIMUM 150mm ABOVE 4. ALL WATER QUALITY TREATMENT DEVICES REQUIRE PERIODIC MAINTENANCE. REFER TO OPERATION AND
OUTLET INVERT LEVEL MAINTENANCE MANUAL FOR GUIDELINES AND ACCESS REQUIREMENTS.
5. SITE SPECIFIC PRODUCTION DRAWING WILL BE PROVIDED ON PLACEMENT OF ORDER.
6. DRAWING NOT TO SCALE.
INLET PIPE INSTALLATION NOTES
OVERFLOW WEIR
1475
(BY OTHERS)
1. ANY SUB-BASE, BACKFILL DEPTH, AND/OR ANTI-FLOTATION PROVISIONS ARE SITE-SPECIFIC DESIGN CONSIDERATIONS
SEE DESIGN TABLE
FOR
WEIR HEIGHT (H)
AND SHALL BE SPECIFIED BY CERTIFYING ENGINEER.
2. CONTRACTOR TO PROVIDE ALL EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE
OUTLET PIPE STORMFILTER STRUCTURE (LIFTING DETAIL PROVIDED SEPARATELY).
(BY OTHERS)
3. CONTRACTOR TO APPLY SEALANT TO ALL JOINTS AND TO PROVIDE, INSTALL AND GROUT INLET AND OUTLET PIPES.
NOT
200
OCEAN PROTECT
FALSE FLOOR UNDERDRAIN 7 CARTRIDGE STORMFILTER SYSTEM
DN2250 MANHOLE
SECTION A-A SPECIFICATION DRAWING
LAST MODIFIED: 09-11-18 PHONE: 1300 354 722 www.oceanprotect.com.au