Minor Change Existing Approval - RAL18/0023 02 (As Published) · RAL18/0023.02

of 18

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

                      Acoustic Measures for Residential Lots & Office Lot
               5.     Prepare and submit to Council for approval with an Operational Works application a revised
                      acoustic report which includes measures to mitigate noise generate from the shopping centre
                      operations and equipment, including deliveries, truck movements and rubbish collection.
                      This report should consider attenuation at the noise source as well as a noise barrier along
                      the shared boundary of Lots 19 and 21. All measures to mitigate noise must be implemented
                      prior the submission of the subdivision plan to Council.
                      Noise attenuation is required to achieve the following acoustic quality for potential residential
                      uses on Lots 17-19. The measurement location must include receivers being placed at the
                      closest point to the future residential and office buildings.

                                                                            Criteria (measured at the receptor) dB(A)
                          Sensitive receptor            Time of Day

                                                                              LAeq,adj,1hr 1          LA1,adj,1hr2

                                                    Daytime and evening
                                                                                   35                     45
                                                     (habitable spaces)
                          Dwelling (indoors)
                                                     Night-time (sleeping
                                                                                   30                     40
                                                            areas)
                      1Acoustic        descriptor/noise target for continuous noise sources (eg. Mechanical plant).
                      2Acoustic descriptor/noise target for transient impacts arising from loading dock activities

                      (e.g. truck movements, reversing alarms, compactor, trolley etc.)
                      Water & Sewer Connections
               6.     An underground connection to reticulated water and sewerage must be provided to each lot
                      in accordance with the standards and requirements of Northern SEQ Distributor– Retailer
                      Authority (Unitywater).
                      A Certificate of Completion from the Northern SEQ Distributor–Retailer Authority (Unitywater)
                      must be submitted to Council that certifies an underground connection to reticulated water
                      and sewerage has been provided to each lot.
                      External Works
               7.     Prior to the sealing of the survey plan a vehicle access to proposed Lot 23 must be
                      constructed at no cost to Council. The works must be undertaken in accordance with an
                      Operational Works approval, be generally in accordance with drawing number 1856-R08
                      Revision J prepared by Barlow Shelley and include an access extending from the existing
                      roundabout in Walter Hay Drive to the property boundary.
               8.     Prior to the sealing of the survey plan a new emergency vehicle exit from proposed Lot 23
                      must be constructed at no cost to Council. The works must be undertaken in accordance
                      with an Operational Works approval. The exit must extend from the property boundary to the
                      existing formation of the south bound lanes of Walter Hay Drive and be for emergency
                      vehicles only. The exit must:
                      8.1. be located in the north western section of the Walter Hay Drive frontage
                      8.2. include a crossing in the median of Walter Hay Drive that is sufficient to permit
                           emergency vehicles to exit the site and access the north bound lanes of Walter Hay
                           Drive




                                                                                                          Page 3 of 18
Document Set ID: 24498083
Version: 5, Version Date: 02/02/2026

Used in these records

About this file

File size
432 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Minor Change Existing Approval - RAL18_0023 02 (As Published).pdf · 432 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.