ORDINARY MEETING AGENDA 16 FEBRUARY 2017
a. Sound lock doors must be installed at the proposed smoker’s terrace as
detailed in the development application plans (Rubicon: Proposed Ground Floor
Plans: Stage 4 plan and Stage 5 & 6 plan).
b. Driveways, ramps and car park areas must be finished with surface coatings
which prevent tyre squeal (an uncoated surface is acceptable).
c. All drainage grating over trafficable areas must be secured in a way that
prevents rattling or nuisance noise.
d. Car park exhaust ducting is to have acoustic insulation before and after any
right angle bend (900) at the outlet end of the exhaust fan/s.
e. Car park exhaust discharge riser is to be lined with 50mm thick insulation
(hydrophobic fibreglass batts min. 32kg/m2 ) faced with perforated metal (min.
12% open face area)
f. A minimum Rw 34 (i.e. 10.76mm laminate in acoustic grade frames and
acoustic seals) must be used for all new external windows and glass doors of
the function / dining extension, children’s lounge and the new alfresco lounge.
g. New external walls of areas where amplified entertainment is proposed should
be constructed to achieve a minimum Rw rating of 50.
h. Roof/ceiling of areas where amplified entertainment is proposed should be
constructed to achieve a minimum Rw rating of 50.
i. At the time of installation, new mechanical plant and equipment, a/c units,
motors, refrigeration equipment, compressors, pumps etc associated with
Stage 4 of the development, should be installed within the building or suitably
provided with noise reduction measures and located as to prevent a noise
nuisance beyond the boundary of the site and not exceed the levels specified in
Table 1.
TABLE 1
NOISE LIMITS AT A SENSITIVE RECEPTOR
Noise level at noise sensitive place measured as the adjusted
PERIOD
maximum sound pressure level (L10, adj,T)
7am – 6pm Background noise level (L90,T) plus 5 dB(A)
6pm – 10pm Background noise level plus 5 dB(A)
10pm – 7am Background noise level plus 3 dB(A)
NOISE LIMITS AT A COMMERCIAL PLACE
Noise level at a commercial place measured as the adjusted
PERIOD
maximum sound pressure level (L10, adj,T)
7am – 6pm Background noise level (L90,T) plus 10 dB(A)
6pm – 10pm Background noise level plus10 dB(A)
10pm – 7am Background noise level plus 8 dB(A)
Acoustic Report
2021. An acoustic report prepared by a suitably qualified person* is to be submitted to
Council confirming assessment and certification of measured noise levels from the
new mechanical plant and equipment, a/c units, motors, refrigeration equipment,
compressors, pumps etc comply with the noise limits as set out in Table 1 and all
other relevant noise conditions of this Decision Notice associated with Stage 4 of the
development.
2122. The report is to be submitted after commissioning any new equipment (with all plant
and equipment operating at the same time) and when all building extensions are