Skip to the record
The first. The best. The only NoosaWatch™.

Council archive · source document

Minor Change Existing Approval DBW21/0208.01 {As Published}

of 8

Text shows just the words. Original shows the document exactly as it was published.

                      ENGINEERING
                      Site Access and Driveway
               15.    A sealed access driveway must be provided from Plover Street to all parking and
                      manoeuvring areas of the development. The works must be undertaken in accordance with
                      an Operational Works approval, be generally in accordance with BG & E’s Proposed
                      Driveway and Carport Layout Plan (SK-C-0001, Rev C) dated 17 February 2023 and must
                      include in particular:
                      a.      a driveway crossover generally in accordance with RS-049, RS-050 and any
                              associated addendum;
                      b.      a driveway and driveway crossover design with suitable vertical clearances that will
                              avoid B99 vehicles scraping or bottoming out when entering and exit the subject site;
                              and
                      c.      the construction of the driveway crossover must not create any trip hazards in Council’s
                              road reserve, any reshaping of Council’s road reserve is limited to a maximum 1 in 10
                              grade and must be done so without the use of privately owned retaining structures.
               16.    An arborist report supporting the retention and removal of the existing trees must be
                      submitted and accepted by Council as part of the Operational Works application. The report
                      must be prepared by a suitably qualified arborist.
               17.    The construction of the access driveway must be done under the supervision of a suitably
                      qualified arborist to ensure the remaining vegetation is not adversely affected.
                      Stormwater Drainage
               18.    The site must be provided with a stormwater drainage system connecting to a lawful point of
                      discharge. The works must be undertaken in accordance with an Operational Works
                      approval, be done so without the use of mechanical pumps or the like and without causing
                      scour or damage to the subject site or any adjoining properties.
                      Easements
               19.    Unless otherwise agreed in writing by the relevant service provider, any public or third party
                      infrastructure located on the subject site must be placed within an easement registered
                      against the title of the property.
               20.    All easements must be designed in accordance with the planning scheme and granted at no
                      cost to the Grantee. Where the Grantee is Council or a service authority, the easement
                      documentation must be in accordance with the Grantee’s standard easement terms. Draft
                      easement documentation must be submitted to Council for endorsement.
               21.    All works must be kept clear of any existing or proposed easements on the subject land,
                      unless agreed otherwise in writing by the Grantee.
                      Geotechnical Stability
               22.    All works must be carried out in accordance with a Geotechnical Report (or part thereof)
                      prepared by a qualified person* and endorsed through an Operational Works approval.
                      *(Refer to Advisory Note)
                      Earthworks and Retaining Walls
               23.    All earthworks and associated batters must be undertaken in accordance with an Operational
                      Works approval and contained entirely within the subject site unless written permission from
                      the respective landowner(s) is provided to Council.
               24.    All retaining walls must be designed and constructed in accordance with the planning scheme
                      and must be certified by an RPEQ where exceeding 1.0m in height. All retaining walls that
                      are publicly accessible and exceed 1.0m in height must be fitted with a commercial grade
                      safety fence.



                                                                                                         Page 4 of 8
Document Set ID: 23314163
Version: 3, Version Date: 22/10/2024
Log in to download the original file

Minor Change Existing Approval DBW21_0208.01 {As Published}.pdf · 174 KB (small file)