Council archive · source document
130814 Acoustic Report 230913 · MCU13/0171
Cooroy Property Trust Pty Ltd c/- Lavin Trading Environmental Noise Level Study for Proposed Wimmers Soft Drink Manufacturing Facility, 271 Lake Macdonald Drive, Lake Macdonald Page 12 of 32 • people talking: 60 dB(A) LA10,adj,T @ 10 m – 28 (distance) – 3 (ground) = 29 dB(A); 62 dB(A) LAmax,T @ 10 m – 28 (distance) – 3 (ground) = 31 dB(A); • car driving on site: 50 dB(A) LA10,adj,T @ 8 m – 28 (distance) – 2 (ground) = 20 dB(A); 55 dB(A) LAmax,T @ 8 m – 28 (distance) – 2 (ground) = 25 dB(A); • car door closing: 52 dB(A) LA10,adj,T @ 30 m – 18 (distance) – 3 (ground) = 31 dB(A); 55 dB(A) LAmax,T @ 30 m – 18 (distance) – 3 (ground) = 34 dB(A); • car engine starting: 52 dB(A) LA10,adj,T @ 30 m – 18 (distance) – 3 (ground) = 31 dB(A); 55 dB(A) LAmax,T @ 30 m – 18 (distance) – 3 (ground) = 34 dB(A); • forklift operating: 78 dB(A) LA10,adj,T @ 10 m – 28 (distance) – 8 (building) = 42 dB(A); 80 dB(A) LAmax,T @ 10 m – 28 (distance) – 8 (building) = 44 dB(A); • waste collection vehicle: 73 dB(A) LA10,adj,T @ 10 m – 28 (distance) – 3 (ground) = 42 dB(A); 73 dB(A) LAmax,T @ 10 m – 28 (distance) – 3 (ground) = 42 dB(A); • manufacturing: 90 dB(A) LA10,adj,T @ 1 m – 5 (inside to outside factory via open doors) – 42 (distance) – 4 (ground) = 39 dB(A); 92 dB(A) LAmax,T @ 1 m – 5 (inside to outside factory via open doors) – 42 (distance) – 4 (ground) = 41 dB(A). Steady state noise • office airconditioning unit: 82 dB(A) SWL – 54 (distance) – 8 (building) = 20 dB(A); • cooling tower: 80 dB(A) LA10,adj,T @ 1 m – 47 (distance) – 8 (building) = 25 dB(A); • exhaust fans: 65 dB(A) LA10,adj,T @ 1 m + 10 (ten to 12 fans operating) – 48 (distance) – 5 (barrier, roof edge) = 22 dB(A); • pumps: 70 dB(A) LA10,adj,T @ 1 m + 10 (ten to twelve pumps operating) – 48 (distance) – 8 (building) = 24 dB(A); • combined noise: 20 + 25 + 22 + 24 = 29 dB(A) LA10,adj,T. All of the above noise sources comply with the time varying and steady state noise limits at the closest residence to the south-east. David Moore & Associates Pty Ltd Our reference: R13095/D2847/Rev.0/23.09.13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
130814 Acoustic Report 230913Related documentApplication case desk ↗
About this file
- File size
- 2.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.