Part 20 of 37 Appendix 18 - Integrated Water Cycle Management Plan MCU12/0208
Plans and drawings: the text below has words only, no drawings.
Very large file (23.8 MB): may take a few minutes to open.
www.ac ss.gs
+GILBERI
SlJT1-ERI.
Different tank sizes were assessed for each of the inflow
rainfall data sets reviewed in section 6.1 and for
(8)Less spill 85,785 81,229 76,268
the assumptions presented in tables 6.2.1 and
(C)Total
6.2.2. A summary of these assessments is 53,004 57,542 62,460
available for use
presented in Tables 6.2.3, 6.2.4 and 6.2.5. The
rainfall tank assessment is based on the daily (D)Demand 72,301 72,301 72,301
data for each location and has been modelled on (E)Potable
a daily time-step. supplemented 19,255 14,716 9,799
demand
Table 6.2.3 Average annual rainfall balance for
Noosaville (SILO)
6.3 Precinct approach -
total catchment
I Noosaville rainfall capture and reuse
3kL Tank 5kL Tank 10kL
Annual Total (L) A catchment scale rainfall tank assessment was
Tank
undertaken to determine the total rainfall capture
(A)Total rainfall and re-use for the site. This forms part of the
156,204 156,204 156,204
inflow
preliminary planning process of integrated water
(8)Less spill 95,933 91,730 87,289 cycle management for Noosa on Weyba. The
rainfall tank assessment is based on the daily
(C)Total
60,247 64,434 68,915
available for use rainfall data assumed for the development area
and has been modelled on a daily time-step. The
(D)Demand 72,301 72,301 72,301
rainfall assessment has been based on the
(E)Potable
proposed land use precinct planning presented in
supplemented 12,051 7,864 3,464
demand
Figure A2 in Appendix 1.
Table 6.2.4 Average annual rainwater tank The assessment for each of the precincts (with
balances for Tewantin RSL park rainfall station the exception of Precincts C and E(b)), has been
based on the assumption of one (1)freestanding
I Tewantin RSL Park
tank per dwelling. For Precinct C, the connected
3kL Tank 5kL Tank 10kL
Annual Total (L) roof area of the apartment buildings has been
Tank
based on an assumption of four (4), three-storey
(A)Rainfall
145,007 145,007 145,007 buildings of 12 or 13 units in each block. The
inflow
mixed-use would comprise retail/commercial
(8)Less spill 86,304 81,633 76,371
space on the ground floor of each block and on
(C)Total the apartments above. The roof area for tank
58,515 63,061 68,011
available for use inflow has been calculated on 7 apartments per
level with individual floor areas of 80m2 giving a
(D)Demand 72,301 72,301 72,301
total roof area of 560m2 per building. Each
(E)Potable
apartment building within Precinct C has been
supplemented 13,600 9,054 4,104
assessed on the assumption of using three (3)
demand
10kL rainwater tanks.
Table 6.2.5 Average annual rainwater tanks The assumptions for the various analyses are
balance for Eumundi-Crescent Road rainfall station presented in Tables 6.3.1. 6.3.2 and 6.3.3 and
I Eumundi-Crescent Road present the results of the annual average rainfall
tank performance by precinct using data from the
3kL Tank 5kL Tank 10kL
Annual Total (L) Noosaville and Tewantin RSL Park rainfall
Tank
stations.
(A)Rainfall 138,816 138,816 138,816
18 AGRICULTURE WATER ENVIRONMENT
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 20 of 37 Appendix 18 - Integrated Water Cycle Management Plan MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 23.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.