Council archive · source document
07/2446 - 6 Copies of environmental noise level study [As Published] · 132007.2446
Mixstone Pty Ltd Environmental Noise Level Study for Proposed Residential - Budget Accommodation - Development, 102 Pacific Avenue, Sunshine Beach Page 5 of 19 Vehicle Movements on Site, People Noise The noise of vehicle activities and people laughing and talking are time varying. To the best of the consultant's knowledge the local Council does not have any noise limits specific to these types of noise, for this type of operation. With respect to the Environmental Protection legislation and other local authorities, for time-varying noise sources, the selected noise limit criteria should ensure that the existing acoustic amenity does not significantly deteriorate. A change in noise level of 5 dB(A) is clearly perceptible, whereas a change of 3 dB(A) is only just perceptible. On this basis, the noise limit for time-varying noise is that, for like parameters, the source noise level combined with the ambient noise level should not exceed the ambient noise level by more than 3 dB(A), after due consideration of tonality and impulsiveness. This is equivalent to the source noise level alone, for the stated parameter, not exceeding the ambient noise level, after due consideration of tonality and impulsiveness. Therefore, for time-varying noise, the noise limit is that the adjusted source noise should not exceed the ambient noise, for the daytime and evening. This is called the ‘like parameter’ noise limit criteria and has been applied by a number of loca! authorities (eg Brisbane and Logan City Councils) to this type of noise. For time varying noise during the night-time (10 pm to 7 am), a different noise limit is applicable, namely the sleep disturbance criteria. “.. Research adopted by the World Health Organisation (WHO), concludes that for short duration variable noise sources the onset of sleep disturbance commences at internal Lmax noise levels of between 45 dB(A) and 50 dB(A). Due to the location of the subject site in a residential area the adopted noise limit is 45 dB(A) Lamax. Plant Noise The noise of airconditioning units and swimming pool equipment (including spa) are steady state. For steady-state noise, the commonly applied noise limit criteria are as follows: e daytime (0700 to 1800 hours): background + 5 dB(A) ¢ evening (1800 to 2200 hours): background'+ 5 dB(A) e night-time (2200 to 0700 hours): background + 3 dB(A), where the noise limit is expressed as the A-weighted average of the maximum source noise levels, adjusted for tonality and/or impulsiveness. TRAFFIC NOISE Measured Noise Levels For details of the measurement equipment, equipment settings, calibration, monitoring location and atmospheric conditions, refer Appendix A. Appendix B details all of the results of the noise level measurements. In accordance with Appendix B, the following noise levels should be noted: © Lato,1en = 66.9 dB(A) © — Lator2n = 68.3 dB(A) @ — Lagoeh (10 pm to 6 am) = 37.7 dB(A) © ~~ Lago,1en (6 am to midnight) = 49.2 dB(A). David Moore & Associates Pty ud : oO Our reference: RO9043/D2260/Rev.0/23.04.09 we et tee Os oo Rt we a ona legal ¥y ?
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2446 - 6 Copies of environmental noise level study [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.7 MB (small file)
- File type
No other editions are linked here.