07/2446 - 6 Copies of environmental noise level study [As Published] · 132007.2446

of 24

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Mixstone Pty Ltd *
Environmental Noise Level Study for Proposed Residential - Budget ‘s
Accommodation - Development, 102 Pacific Avenue, Sunshine Beach Page 6 of 19 ,

All of the above noise level measurements were free-field, measured from the Pacific Avenue
boundary of the subject site, set back approximately 14 metres from the centre of traffic on Pacific
Avenue with the microphone elevated 2.0 metres.

Predicted Traffic Noise Level Increase

In accordance with the Department of Main Roads traffic noise generally increases by 3.5% per
annum, with traffic noise impact considered for a 10 year horizon. By calculation this increase in traffic
volume will increase traffic noise levels by 1.5 dB(A). Therefore, at monitoring location A the ultimate
traffic noise level will be 66.9 + 1.5 = 68.4 dB(A) Laiorsn.

Ultimate Traffic Noise Levels

For ultimate traffic volumes, the traffic noise levels at approximately 14 metres from the centre of
traffic on Pacific Avenue at monitoring location A will be:

© — Latorsn = 66.9 + 1.5 = 68.4 dB(A)
© ~— Lato2n Maximum = 68.3 + 1.5 = 69.8 dB(A)

Traffic Noise Control - External Living Areas

The noise limit for communal external areas is 63 dB(A) Lato,12-

There are no private external living areas within the proposed budget accommodation facility, but
there is communal external living areas, namely the sun-deck and spa pool area at ground level. At

these communal external living areas ultimate traffic noise levels will be:

* spapool: 69.8 dB(A) Laio12;@ monitoring location A — 3.7 (increased separation distance) —
5.6 (reduced angle of view) = 607.5 dB(A) Lato124, Which complies with the noise limit;

« sun-deck: 69.8 dB(A) Laio,12” @ monitoring location A — 2.8 (increased separation distance) —
5.6 (reduced angle of view) = 61.4 dB(A) Laio,124, which complies with the noise limit;.

 

Based on the above calculations ultimate traffic noise levels will comply with the noise limits at the a
communal external living areas, namely the spa pool and sun-deck, with no traffic noise control ~
measures required. po,

 

Traffic Noise Control - Internal Living Areas nd

in accordance with the Noise Impact Assessment Planning Scheme Policy, the noise limits for internal . .
areas are: a

© 40 dB(A) Laeg,r for living areas and bedrooms during daytime and evening; and .
35 dB(A) Laeg.r for bedrooms during the night-time. not

 

The TNR values, therefore, would be, relative to monitoring location A:

 

e living areas: 67.8 + 1.5 (increased traffic volume) — 40 = 29.3 dB(A)
« bedrooms: 63.3 + 1.5 (increased traffic volume) — 35 = 29.8 dB(A).

To determine the minimum requirements for Rw values of materials of construction for the proposed
budget accommodation, the following formula from Australian Standard AS 3671-1989 was used:

TNAc = TNR + 10 logo [(Sc +S) x (3 = h) X 2Tg0 x C] :

 

 

David Moore & Associates Pty Ltd . Our reference: R09043/D2260/Rev.0/23.04.09 Y

Used in these records

About this file

File size
1.7 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2446 - 6 Copies of environmental noise level study [As Published].pdf · 1.7 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.