Skip to the record
NoosaWatch™: The source of truth.

Council archive · source document

07/2446 - 6 Copies of environmental noise level study [As Published] · 132007.2446

of 24

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Mixstone Pty Ltd
Environmental Noise Level Study for Proposed Residential - Budget
Accommodation - Development, 102 Pacific Avenue, Sunshine Beach Page 7 of 19

where TNAc_ = traffic noise attenuation required for the component

TNR = traffic noise reduction

Sc = surface area of the component
St = surface area of the floor

h = ceiling height

Teo = reverberation time = 0.5 seconds
Cc = number of components.

Rw= TNAc + 6 (approximately).

For the closest (and most exposed) rooms to Pacific Avenue the minimum Rw requirements are
detailed in Table 1. For any rooms not included at Table 1, standard materials of construction,
including standard glazing, would provide adequate rail noise level reduction to the interior. Refer
Appendix C for details of calculations.

 

 

 

 

 

 

 

 

 

 

 

Ter!

 

 

 

 

 

Table 1
Calculated Minimum Rw Requirements for Traffic Noise
3 x Minimum Rw Requirements
a z Room External Walt Roof/Ceiling Window Sliding Glass
. Door

Lower B Reception ‘40 - 34 30
Lower B Kitchen 31 - 26 29
Lower B Dining 32 - 25 25
Lower B Manager 27 - - -
Lower A 3-bed Dorm 35 - 22 31
Lower A 3-bed Dorm 35 - 22 31
Upper 8B 4-bed Dorm 38 37 39 33
Upper B 4-bed Dorm 34 ; 35 28 -
Upper B 4-bed Dorm 29 35 - 31
Upper B 2-bed Dorm 32° 34 28 -
Upper A 3-bed Dorm 35 34 - 31
Upper A 3-bed Dorm 35 34 - 31

 

 

 

 

 

 

 

 

For the minimum Rw requirements detailed above, the following examples of materials of construction
and their associated Rw ratings should be noted:

 

 

 

 

 

 

 

 

 

 

RoofiCeiling

Rw 33 to 35: standard metal or tile pitched roof with 10 mm thick plasterboard ceiling

Rw 36 to 38: as above, but with two-sided aluminium foil over the rafters

Rw 39 to 41: standard metal or tile pitched roof with 10 mm thick plasterboard ceiling and 50 mm thick 12
kg/m® glass fibre blanket between the ceiling joists

Rw 42 to 44: standard metal or tile pitched roof with 10 mm thick plasterboard ceiling and 75 mm thick
mineral wool batts between ceiting joists

Rw 45 to 47: as above, but with 100 mm thick 4.5 kg/m? cellulose fibre fluff between ceiling joists.

Rw 48 to 50: concrete slab 100 mm thick.

 

 

 

poe Our reference: R0$043/D2260/Rev.0/23.04.09

      

 

4

 

 

 

 

 

 

 

Used in these records

About this file

File size
1.7 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2446 - 6 Copies of environmental noise level study [As Published].pdf · 1.7 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.