FPE Ref: 6195-220404-1.0



  bunded. The disposal area should also be planted with water tolerant turf or shrubs to maximise nutrient
  uptake and transpiration and reduce erosion potential.

  Adequate area is considered to be available on the proposed allotments to accommodate a suitable
  irrigation system allowing for relevant setback requirements. The required setback distances as
  nominated in the Queensland Plumbing and Wastewater Code have been summarised in Table 6 of this
  report.

  It has been assumed that the irrigation area above the Q100 flood level. However, if effluent irrigation is
  to occur below the Q100 flood line, additional precautionary measures are to be considered, such as
  raised garden beds and higher standards of treatment should be considered.

  It is a standard requirement to have a reserve area set aside within the allotments in the event that
  problems occur with the operational effluent disposal area. The size of the allotments suggest that there
  will be sufficient space for a 100% reserve area on the site. An indicative Irrigation Area Layout Plan is
  shown in Appendix E.

            SETBACK DISTANCES

  The setback distances from the effluent disposal area shall comply with the Queensland Plumbing and
  Wastewater Code which is summarised below:

  Table 7. Recommended Setback Distances for Secondary and Advanced Secondary Effluent

                       Feature                                Recommended Separation Distance

     Footings or Buildings                       Boundaries of land application areas should be positioned at
                                                 least 2.0m down slope or 4.0m up slope from the footing or
                                                 where the site is flat, 2.0m from any point of the building footing

     Property boundaries, pedestrian paths and   Boundaries of land application areas should be positioned at
     walkways, recreation areas                  least 2.0m down slope, or 4.0m up slope or where the site is flat,
                                                 2.0m from any point

     Retaining wall footing                      Boundaries of land application areas should be positioned at
                                                 least 2.0m down slope, or 4.0m up slope from the retaining wall
                                                 footing or where the site is flat, 2.0m from any point of the
                                                 building footing

     In ground swimming pool                     Boundaries of land application areas should be positioned at
                                                 least 6.0m down slope, or 6.0m up slope from the pool or where
                                                 the site is flat, 6.0m from any point




20 April 2022                                Land Suitability Report                                                   10
                                                CYC Campsite
                                           48 Kabi Road, Cootharaba
Log in to download the original file

Att11 - Land Suitability (effluent) Report.pdf · 13.4 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.