FPE Ref: 6195-220404-1.0
bunded. The disposal area should also be planted with water tolerant turf or shrubs to maximise nutrient
uptake and transpiration and reduce erosion potential.
Adequate area is considered to be available on the proposed allotments to accommodate a suitable
irrigation system allowing for relevant setback requirements. The required setback distances as
nominated in the Queensland Plumbing and Wastewater Code have been summarised in Table 6 of this
report.
It has been assumed that the irrigation area above the Q100 flood level. However, if effluent irrigation is
to occur below the Q100 flood line, additional precautionary measures are to be considered, such as
raised garden beds and higher standards of treatment should be considered.
It is a standard requirement to have a reserve area set aside within the allotments in the event that
problems occur with the operational effluent disposal area. The size of the allotments suggest that there
will be sufficient space for a 100% reserve area on the site. An indicative Irrigation Area Layout Plan is
shown in Appendix E.
SETBACK DISTANCES
The setback distances from the effluent disposal area shall comply with the Queensland Plumbing and
Wastewater Code which is summarised below:
Table 7. Recommended Setback Distances for Secondary and Advanced Secondary Effluent
Feature Recommended Separation Distance
Footings or Buildings Boundaries of land application areas should be positioned at
least 2.0m down slope or 4.0m up slope from the footing or
where the site is flat, 2.0m from any point of the building footing
Property boundaries, pedestrian paths and Boundaries of land application areas should be positioned at
walkways, recreation areas least 2.0m down slope, or 4.0m up slope or where the site is flat,
2.0m from any point
Retaining wall footing Boundaries of land application areas should be positioned at
least 2.0m down slope, or 4.0m up slope from the retaining wall
footing or where the site is flat, 2.0m from any point of the
building footing
In ground swimming pool Boundaries of land application areas should be positioned at
least 6.0m down slope, or 6.0m up slope from the pool or where
the site is flat, 6.0m from any point
20 April 2022 Land Suitability Report 10