It is recommended that a concrete path with impermeable membrane under, or buried membrane about
1.5m -
2m wide, completely surround each residential building to protect the foundation soils from seasonal
moisture variations. Gardens and lawns (placed over buried membranes) adjacent the building should not
be over-watered. Moderate, frequent watering is the most suitable. Gardens should not be concentrated in
one area but should be spread evenly around the building.
5.3 Effluent Disposal Characteristics
As part of the effluent disposal assessment to be carried out by others, it was requested that the following
tests be carried out to provide an indication of permeability characteristics;
. Textural classifications
. Emerson Class Tests
. Insitu Permeability Tests
Textural Classifications
A total of 16 textural classifications were carried out at varying depths and borehole locations across the site.
These are summarised in Table 4.
The results indicated a variety of soil types across the site ranging from loamy sand to medium clays. Some
classification test results indicated some heavy clays may also exist across the site.
Emerson Class Tests
A total of 11 Emerson Class tests were carried out across the site. These are summarised in Table 3.
The results indicated some variability in dispersiveness across the site.
All 3 samples from the Northbrook title indicated partial or complete dispersion. Only 1 sample from BH9 on
the Hofman title showed partial dispersion.
Insitu Permeability Tests
A total of 7 constant head permeability tests were carried out across the site. The results are summarised in
Table 7 below.
Table 7: Permeability Results
BH No. Depth Saturated Hydraulic conductivity, KSAT
(m) (m/day)
1 0.0-1.0 0.02
9 0.0-1.0 0.05
12 0.0-1.0 1.32
20 0.0-1.0 2.20
32 0.0-1.0 0.02
17 0.0-1.0 0.01
18 0.0-1.0 0.01
The permeability test results show some variability between the sand and clay strata.
Prepared for Cardno (Old) Page 17
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 6 of 37 Appendix 3 - Geotechnical Assessment MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 49.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.