Part 6 of 37 Appendix 3 - Geotechnical Assessment MCU12/0208

of 95

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (49.3 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

                                                                                                                 Noosa on Weyba



The parameters shown in Table 6 may be used for footing design purposes.                            However, if bored piles are
adopted, the base of the piles must be inspected during construction to ensure that material of adequate
capacity supports each pile.
Table 6: Bearing Capacities for Bored Piles

              Material Type                                Design Equivalent          Design Equivalent




                                           FILL
                                                   I         Skin Friction

                                                                  $gfs
                                                                 (kPa)

                                                                   NR
                                                                                I   Base Bearing Capacity

                                                                                            $gfb
                                                                                            (kPa)

                                                                                             NR

                   NATURAL- Loose Sand                              3                        NR

      NATURAL       -
                        Medium Dense Sand                           5                       150

           NATURAL- Soft to Firm Clay                              NR                        NR

                        NATURAL   -
                                      Stiff Clay                   17                       150

     NATURAL   -

                   Very Stiff or Better Clay                       20                       300


                          XW, MUDSTONE                             60                       1000



Notes:

a)    NR = Not Recommended

b)    Ignore top 1.5m of profile in pile capacity calculations.
c)    The above values were compiled assuming that the pile depth will be at least 5 times that of its pile
      diameter.

d)    A geotechnical strength reduction factor (<pg) of 0.4 has been applied to the ultimate parameters in the
      calculation of the above design equivalent capacities.


The advantage of the alternative deep level footing types (driven timber piles, push     piles, screw in steel
piles) is that they can be installed under a performance specification and they can be installed when there is
a high water table or where drilled shafts would collapse without support.



Articulation


It is recommended that the external brickwork walls be articulated by the use of full height (footings to eaves)

openings or vertical construction joints at a maximum spacing of 6.0 metres to prevent cracking of brickwork
caused by possible differential movement of the foundations. This articulation can be achieved by using full

height doors or windows or using flexible cladding over or under them. Construction joints may be hidden by
down pipes. Reference should be made to the Cement & Concrete Association of Australian publication
’Articulated Walling’ Construction Note TN61 for further information regarding articulation.


Maintenance


The importance of avoiding leakage from underground services and drains near the buildings is stressed.

Any leaking services or blocked drains should be remedied promptly.                           For
                                                                                highly expansive clays it is
advisable to use flexible joints allowing horizontal and vertical movement where service pipes pass through
the foundation structure (floor and slab).


Future shrubs and trees should be placed at a distance at least equivalent to their mature height away from
the building for Class ’M’ sites, 1.5 times their mature height for Class ’H1’ and ’H2’ sites to minimise the

potential for the moisture demand causing shrinkage movement in expansive founding soils. Existing trees
in the proposed building area can also cause movement in expansive soil when removed. It is advisable to

remove such trees at least 3 months                    prior to construction.




Prepared for Cardno (Old)                                                                                               Page 16

Used in these records

About this file

File size
49.3 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Part 6 of 37 Appendix 3 - Geotechnical Assessment MCU12_0208.pdf · 49.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.