CHROMIUM SUITE TEST REPORT
Report Number: 3747/S/16578CRS
Client: Card no (Qld)
Client Address: Locked Bag 4006, Fortitude Valley Qld 4006 Date Sampled: 10/05/2012
Project: CBE 10434 Date Received: 10/05/2012
Job no_ 3747/P/242 Date Tested: 18/05/2012
Sampled by: Card no Bowler (Brisbane South) Date Reported: 21/05/2012
Methods: AS 4969.0, .1, .2, .4, .7,.8,.11,.13,.14
Laboratory Number Sample Location pHKc1 TAA TAA SKCI SCr SNAS ANCBT Net Acidity Net Acidity Recommended Liming Rate
units: (Wmollt) (%5) (%5)’ (%5) (%5) (%CaC03), (Wmollt) (%5) (kg of lime per cubic metre)
LOR: 0.1 1 0.001 0.007 0.02 0.001 0.01 1 0.001 0.1
3747/8/16578 BH 15 0.00-0.50 6.0 11 0.017 <0.007 <0.02 nr nr 11 0.017 No Liming Required
3747/8/16582 BH 15 1 .00-1 .50 5.7 17 0.027 <0.007 <0.02 nr nr 17 0.027 No Liminq Required
3747/8/16586 BH 24 0.00-0.50 6.4 3 0.005 <0.007 <0.02 nr nr 3 0.005 No Limina Required
3747/8/16590 BH 24 1 .00-1 .50 5.7 21 0.034 0.007 <0.02 nr nr 21 0.034 3.0
3747/8/16594 BH 25 0.00-0.50 6.0 15 0.024 <0.007 <0.02 nr nr 15 0.024 No Liminq Required
3747/8/16598 BH 25 1 .00-1 .50 5.6 17 0.026 <0.007 <0.02 nr nr 17 0.026 No Liminq Required
3747/8/16602 BH 26 0.00-0.50 5.5 24 0.038 <0.007 <0.02 nr nr 24 0.038 3.4
3747/8/16606 BH 26 1 .00-1 .50 5.2 44 0.071 <0.007 <0.02 nr nr 44 0.071 6.2
Blank 5.2 4.0 0.006
Notes:
nr: notrequired, pH trigger not met. ~ NATA Accreditation No: 3747
This document is issued in
LOR: Limit of Reporting NATA accordance with NATA’s accreditation
#
if pHKc1 <6,5 it must be assumed that effective ANC is zero. requirements.
a
SKCI determined as sulfate by turbidimetric method.
V"
Where liming is specified, lime should be fine grained agricultural lime of at least 90% purity,
Any liming rate provided is a recommended rate only, and is based on the total of TAA Equivalent %Oxidisable Sulphur plus
Potential Acidity (SCr)plus Retained Acidity (SNAS)minus effective ANC; with a factor of safety of 1.5.
Any recommended liming rate is based on the 0.03%5 action criteria.
A placed dry density of 1.7 tonnes/cubic metre has been used in calculating liming rate/so
The recommended liming rate is derived from a mathematical equation and will need to be field validated. SIGNATORY: Paul Mayes
Cardno Bowler Pty Ltd accepts no responsibility for any loss associated with use of the calculated liming rate/so Form Number: REP eRS 28/07/2011 Revision 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 6 of 37 Appendix 3 - Geotechnical Assessment MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 49.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.