Council archive · source document
Part 6 of 37 Appendix 3 - Geotechnical Assessment MCU12/0208
Very large file (49.3 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Cardno Bowler Pty LId Telephone: Facsimile:
ABN 74128 806 735 (07)5450 1544 (07)5450 1533
Cardno
BOWLER Address:
32 Hi-Tech Drive
Email: [email protected]
Website: www.cardno.com.au
Kunda Park Old 4556
Shaping the Future
Card no Bowler Offices:
Brisbane, Cairns, Townsville, Mackay, Rockhampton, Bundaberg, Sunshine Coast, Gold Coast,
Sydney, Deniliquin, Melbourne, Bendiqo, Dandenonq
CHROMIUM SUITE TEST REPORT
Report Number: 3747/S/16610CRS
Client: Card no (Qld)
Client Address: Locked Bag 4006, Fortitude Valley Qld 4006 Date Sampled: 10/05/2012
Project: CBE 10434 Date Received: 10/05/2012
Job no_ 3747/P/242 Date Tested: 22/05/2012
Sampled by: Card no Bowler (Brisbane South) Date Reported: 28/05/2012
Methods: AS 4969.0, .1, .2, .4, .7,.8,.11,.13,.14
Laboratory Number Sample Location pHKc1 TAA TAA SKCI SCr SNAS ANCBT Net Acidity Net Acidity Recommended Liming Rate
units: (Wmollt) (%5) (%5)’ (%5) (%5) (%CaC03), (Wmollt) (%5) (kg of lime per cubic metre)
LOR: 0.1 1 0.001 0.007 0.02 0.001 0.01 1 0.001 0.1
3747/8/16610 BH 30 0.0-0.50 5.4 34 0.055 <0.007 <0.02 nr nr 34 0.055 4.9
3747/8/16614 BH 30 1 .00-1 .50 4.5 124 0.200 <0.007 <0.02 nr nr 124 0.200 17.7
3747/8/16618 BH 31 0.00-0.50 5.5 29 0.047 <0.007 <0.02 nr nr 29 0.047 4.1
3747/8/16622 BH 31 1.00-1.50 4.5 120 0.193 <0.007 <0.02 <0.02 nr 120 0.193 17.1
3747/8/16626 BH 32 0.0-0.50 5.5 34 0.055 <0.007 <0.02 nr nr 34 0.055 4.8
3747/8/16630 BH 32 1 .00-1 .50 5.0 32 0.051 <0.007 <0.02 nr nr 32 0.051 4.5
3747/8/16634 BH 4 0.00-0.50 5.3 24 0.038 <0.007 <0.02 nr nr 24 0.038 3.4
3747/8/16638 BH 4 1.00-1.50 4.6 130 0.208 <0.007 <0.02 nr nr 130 0.208 18.4
Blank 5.2 4.0 0.006
Notes:
nr: notrequired, pH trigger not met. ~ NATA Accreditation No: 3747
This document is issued in
LOR: Limit of Reporting NATA accordance with NATA’s accreditation
#
if pHKc1 <6,5 it must be assumed that effective ANC is zero. requirements.
a
SKCI determined as sulfate by turbidimetric method.
V"
Where liming is specified, lime should be fine grained agricultural lime of at least 90% purity.
Any liming rate provided is a recommended rate only, and is based on the total of TAA Equivalent %Oxidisable Sulphur plus
Potential Acidity (SCr)plus Retained Acidity (SNAS)minus effective ANC; with a factor of safety of 1.5.
Any recommended liming rate is based on the 0.03%5 action criteria.
A placed dry density of 1.7 tonnes/cubic metre has been used in calculating liming rate/so
The recommended liming rate is derived from a mathematical equation and will need to be field validated. SIGNATORY: Paul Mayes
Cardno Bowler Pty Ltd accepts no responsibility for any loss associated with use of the calculated liming rate/so Form Number: REP eRS 28/07/2011 Revision 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 6 of 37 Appendix 3 - Geotechnical Assessment MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 49.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.