Original source · versioned page text
221363 - 2 Kestrel Cres Peregian Beach - Construction of Dwelling, Swimming Pool & Fence - Stamped - Archs
Original PDF page 2, section 1. The text section number identifies this passage in the reader.
ISSUE DATE DESCRIPTION
A 20/12/22 ISSUE FOR CLIENT SIGN OFF - CONCEPT
B 06/02/23 ISSUE FOR CLIENT SIGN OFF - PLANNING
C 14/02/23 ISSUE FOR DEVELOPMENT APPLICATION
D 06/06/23 ISSUE FOR BUILDERS TENDER
E 20/09/23 ISSUE FOR BUILDING APPROVAL
TO BE READ IN CONJUNCTION WITH SURVEY PLAN BY AXIS SURVEYS
K ES
TRE
TBM SCREW IN CHANNEL AHD RL m 23.257 WATER HYD L CRE
2.834m
S
8.604m
3 4m
2.8
m
2.834
13.6 GREY FILL REPRESENTS SEWER
8 5m
ZONE OF INFLUENCE. 1.2m FROM
SEWER LINE & 1.5m FROM
WATER VALVE
MANHOLE. (CAUTION AVOID
WORKS WITHIN - EXACT SEWER
L
O WAL
LOCATION TBC ON SITE)
LL
WA
7222 T
7 TO
LA
679
5
GO
509
PER
TO
0
130
5
RENDERED AND PAINTED BLOCK FENCE (2m MAX, LIGHT
245
COLOUR) GARDEN BED BELOW
LORILET ST
6000 POOL
S
13.00°
LL
WA
TO
60
00
35
46
9700
S
VERTICAL BATTEN FENCE POWDERCOATED
LIGHT (10 x 40mm NOM.) WITH 30mm GAPS
13.00°
13.00°
S
20
00
13.00°
S
BLOCK LETERBOX WITH ELONGATED SPLIT
L L
WA
AND FEATURE HOUSE DIGITS (900NOM)
ING
AIN
13
E
T
LIN
S
RE
9700
.00
ER
STONE CLAD BLOCK FENCE EITHER SIDE OF
CK
° 12
EW
PATH (2m MAX HEIGHT) 00
LO
S
B
ING
ING
IST
IST
RIDGE
EX
EX
S
CONSTRUCTION OF DRIVEWAY AND 4500
13.00°
CROSSOVER TO BE IN ACCORDANCE
WITH NOOSA STANDARD DRAWINGS
5000 MAX
4000 MAX
5000 MAX
(RS049/50) - FINAL SHAPE / SIZE TBC
ON SITE WITH BUILDER + CLIENT
CLIENT:
25
77
ANDREW + ANDREA MACLAREN
S
5.00°
5.00°
2000
1740
MB
1500
SEWER MAN
HWS BINS HOLE
600
TELSTRA
PROJECT:
21.927m
CNR KESTREL CRES & LORILET ST
SETBACK
TIMBER FENCE ON EXISTING BLOCK
WATER RETAINING WALL
6000
EXISTING TIMBER FENCE
LAUNDRY & BATHROOM
POP OUT TO COMPLY
BUILT TO BOUNDARY WITH 1.5M SETBACK FROM
WALL (TO COMPLY WITH SOUTHERN BOUNDARY,
QDC, MAX MEAN 4.5M HEIGHT LIMIT)
ARCHITECT:
HEIGHT OF 3.5m + 9m
MAX LENGTH)
M. 0475 030 630
W. honghenwood.com
LOT 39 E. [email protected]
EXISTING HIGHSET HOUSE ABN No. 12822847278
DRAWING TITLE:
SITE LOCATION PLAN
NOTES: NORTH:
1. Use only figured dimensions, do not scale drawings.
2. All discrepancies and omissions to be referred to Hong Henwood
Design prior to construction.
3. Check all dimensions, Building Code of Australia, relevant codes
and council approvals.
4. This drawing is not for construction.
Copyright remains the property of Hong Henwood. Reproduction of the
whole or part of this document constitutes an infringement of copyright.
5. Nominated Architect: Karen Leech QLD 5795
20/09/2023 4:36:17 PM
SITE PLAN SCALE: DATE:
1 : 100 @ A1 11/08/23
1 Scale: 1 : 100 DRAWN BY: CHECKED BY: PROJECT NO: ISSUE:
DRAWING NO:
KL HH 2216
CAD FILE: A0001 E
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.