                                                                                                                                                                                                                                                                                                                                                                                            ISSUE        DATE                                                           DESCRIPTION
                                                                                                                                                                                                                                                                                                                                                                                             A        20/09/23          ISSUE FOR BUILDING APPROVAL


PROJECT                   NOTES                                                                                                                                                                                                                                                         ABBREVIATIONS                                  SYMBOL LEGEND
COPYRIGHT: DRAWINGS REMAIN THE COPYRIGHT OF HONG HENWOOD DESIGN                             ELECTRICAL                                                                                            ALL DRAWINGS TO BE READ IN CONJUNCTION WITH ALL OTHER                                 ADJ.      ADJUSTABLE                             1     CALLOUT TAG DENOTES SHEET NUMBER,
ALL WORKS SHALL BE CARRIED OUT IN ACCORDANCE WITH THE BUILDING                              SMOKE ALARMS COMPLYING WITH AS 3786 TO BE INSTALLED AND CONNECTED TO                                  CONSULTANTS DRAWINGS, SPECIFICATIONS, NOTES AND                                       AFFL      ABOVE FINISHED FLOOR LEVEL           A0000   DENOTES DETAIL NUMBER
CODE OF AUSTRALIA, AUSTRALIAN STANDARD, LOCAL COUNCIL                                       CONSUMER MAINS POWER IN ACCORDANCE WITH NCC PART 3.7.2                                                CORRESPONDENCE ISSUED DURING THE COURSE OF THE CONTRACT.                              AHD       AUSTRALIAN HEIGHT DATUM
REQUIREMENTS, QDC GUIDELINES AND ALL OTHER RELEVANT BY LAWS AND                                                                                                                                                                                                                         AL        ALUMINIUM                             D      DOOR TAG REFER TO DOOR SCHEDULE A5000
AUTHORITIES.                                                                                PROVIDE LIGHTING IN ACCORDANCE WITH NCC VOL 2 PART 3.8.4.2 & 3                                        THE INFORMATION CONTAINED ON THESE DRAWINGS ARE FOR                                   AP        ACCESS PANEL                         101
                                                                                            PROVIDE VENTILATION IN ACCORDANCE WIH NCC VOL 2 PART 3.8.5                                            ARCHITECTURAL PURPOSES ONLY, ALL DISCREPANCIES OR OMISSIONS ARE                       AS        AUSTRALIAN STANDARD                          CEILING TAG (XXxx) DENOTES FINISH REFER TO
MINIMUM DESIGN STANDARDS                                                                    MECHANICAL VENTILATION IN ACCORDANCE WITH NCC VOL 2 AND AS 1668.2                                     TO BE NOTIFIED TO THE ARCHITECT                                                       AV        AUDIO VISUAL                                 SCHEDULE, (CH:XXXX) DENOTES HEIGHT ABOVE
CONSTRUCTION OF THIS BUILDING TO BE IN ACCORDANCE WITH THE                                                                                                                                                                                                                              BAL       BALUSTRADE TYPE                              FFL
FOLLOWING GOVERNING BODIES                                                                  STRUCTURAL                                                                                            MATERIALS, FINISHES AND FIXTURES CODES                                                BCA       BUILDING CODE OF AUSTRALIA
- NATIONAL CONSTRUCTION CODE (NCC)                                                          ALL WORK TO COMPLY WITH STRUCTURAL SOUNDNESS DESIGN CRITERIA. REFER TO                                TO BE READ IN CONJUCTION WITH FIXTURES AND FINISHES SCHEDULES.                        BS        BASIN                                  WX    WINDOW TAG
- QUEENSLAND DEVELOPMENT CODE                                                               STRUCTURAL ENGINEERS DOCUMENTATION. ALL SLABS, ROOF STRUCTURE AND                                     FINISHES AND FIXTURES TO INTERIOR DESIGNERS DETAILS                                   CA        CARPET
- STANDARD BUILDING REGULATION 2006                                                         FRAMING TO STRUCTURAL ENGINEERS SPECIFICATION.                                                                                                                                              CH        CEILING HEIGHT                         W1    WALL TAG REFER TO WALL TYPE SCHEDULE
- LOCAL COVERNMENT PLANNING POLICIES                                                        ALL STRUCTURAL STEEL TO STRUCTURAL ENGINEERS DETAILS AND SPECIFICATIONS.                              ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE NOTED                              CHS       CIRCULAR HOLLOW SECTION                      A5200
                                                                                            ALL STRUCTURAL STEEL TO BE PROTECTED FROM CORROSION WITH APPLIED                                                                                                                            CJ        CONTROL JOINT
IN PARTICULAR, REFER AUSTRALIAN STANDARDS:                                                  FINISHES TO DESIGNERS DETAILS.                                                                                                                                                              CL        CENTRELINE                                   SPOT LEVEL (RL)
                                                                                            FIRE RATING OF STRUCTURAL STEEL IS REQUIRED IN ACCORDANCE WITH BCA AND                                SITE MEASURE: ALL JOINERY TO BE SITE MEASURED ONCE LININGS ARE
                                                                                                                                                                                                                                                                                        COL       COLUMN TO STRUCTURAL ENG
1.       site preparation A.S. 3798                                                         FIRE ENGINEERING REPORTS. ALL DIMENSIONS ARE TO BE CONFIRMED ONSITE PRIOR                             IN PLACE. CONFIRM ANY DISCREPENCIES PRIOR TO FABRICATION.
                                                                                                                                                                                                                                                                                        CON       CONCRETE                                     STEP IN SLAB
2.       concrete construction A.S. 2870                                                    TO CONSTRUCTION / FABRICATION. UNLESS OTHERWISE NOTED, ALL EXPOSED                                                                                                                          COS       CHECK ON SITE
3.       timber construction and details A.S. 1684.2                                        STRUCTURAL STEEL, ANCHOR BOLTS AND OTHER ATTACHMENTS SHALL BE HOT DIP                                 DOCUMENTATION: The contractor shall carry out works in accordance with the
                                                                                                                                                                                                                                                                                        DDA       DISABILITY DISCRIMINATION ACT
4.       steelwork AS 4100, AS 1111 and A.S. 1112                                           GALVANISED. CHECK ALL DIMENSIONS ON SITE PRIOR TO FABRICATION OF STEEL                                signed drawings and schedules and anything reasonable inferred, and with the
                                                                                                                                                                                                                                                                                        DIA       DIAMETER
5.       termite protection BCA and A.S. 3660.1                                             WORK                                                                                                  Conditions of Contract, and in accordance with the directions and to the
                                                                                                                                                                                                                                                                                        DGPO      DOUBLE GPO
6.       artificial lighting & ventilation BCA parts 3.8.4/3.8.5 and A.S. 1680                                                                                                                    satisfaction of the Architect, whose interpretation of the contract documents shall
                                                                                                                                                                                                                                                                                        DH        DOOR HARDWARE
7.       fire safety BCA part 3.7                                                           CONSULTANTS: Drawings shall be read in conjunction with engineers drawings and                        be final. The drawings and specifications/schedules shall be considered
                                                                                                                                                                                                                                                                                        DP        DOWNPIPE
8.       smoke alarms BCA part 3.7.2 and A.S. 3786                                          computations. All structure to Engineers design. Hydraulic sizing and design to hydraulic             complementary, and any work and/or materials absent from one but present or
                                                                                                                                                                                                                                                                                        DPC       DAMP PROOF COURSE
9.       glazing BCA part 3.6 and A.S. 1288 and A.S. 2047                                   engineers requirements if applicable. All drawings to be co-ordinated with consultant                 implied in the other shall be furnished as if they were present in both.
                                                                                                                                                                                                                                                                                        DW        DISHWASHER
                                                                                            documentation prior to construction.                                                                                                                                                        DWG       DRAWING
ALL WORKS MUST COMPLY WITH THE NCC, LOCAL AUTHORITY AND ALL                                                                                                                                       FINAL CERTIFICATE: AT COMPLETION OFWORK, BUILDER TO OBTAIN AND
                                                                                                                                                                                                                                                                                        EA        EQUAL ANGLE
RELEVANT GEOGRAPHIC/WIND CATEGORY REQUIREMENTS. ALL CUT AND FILL                                                                                                                                  SUPPLY A CERTIFICATE OF CLASSIFICATION FROM A BUILDING CERTIFIER.
                                                                                                                                                                                                                                                                                        EDB       ELECTRICAL DISTRIBUTION BOARD
BATTERS ARE INDIVATIVE ONLY AND MUST BE ESTABLISHED AND VERIFIED BY                         WATER LINES: ALL HOT WATER LINES SHALL BE FULLY INSULATED. ALL DOMESTIC HOT                                                                                                                 EJ        EXPANSION JOINT
BUILDER/CLIENT IN RELATION TO PROPOSED SLAB AND/OR FLOOR LEVELS.                            WATER TO BASINS, SHOWERS AND BATHS TO HAVE A MAXIMUM TEMPERATURE OF 50                                                                                                                      EQ        EQUAL
THESE DRAWINGS ARE TO BE READ IN CONJUCTION WITH OTHER RELEVANT                             DEGREES C. ALLOW TO SUPPLY AND INSTALL TEMPERING VALVES WHERE REQUIRED                                                                                                                      EX        EXISTING
CONSULTANT DRAWINGS AND REPORTS                                                             AS NOMINATED IN THE BCA AND RELEVANT STANDARDS.                                                                                                                                             EX. COL   EXISTING STRUCTURAL COLUMN
                                                                                                                                                                                                                                                                                        FCL       FINISHED CEILING LEVEL
APPROVAL: NO BUILDING WORK SHALL BE UNDERTAKEN PRIOR TO BUILDING                            STAIR AND BALUSTRADES: ALL STAIRS AND BALUSTRADES SHALL COMPLY WITH PART                                                                                                                    FE        FIRE EXTINGUISHERS / BLANKETS
APPROVAL BY A REGISTERED CERTIFIER                                                          3.9 OF THE BCA.                                                                                                                                                                             FFL       FINISHED FLOOR LEVEL
                                                                                                                                                                                                                                                                                        F         FIXED GLASS
If the contractor finds any inconsistency, error or omission in the documents, or between   TILES: Expansion joints, walls: 5mm. Floors: 8mm. Fill both with silicone rubber. Grout for wall:                                                                                           FH        FIRE HYDRANT
documents, the architect must be notified. The contractor is to read all drawings to        Epoxy based mildew resistant. Grout for floors: prepared grout to be acid resistant. All wall tiles                                                                                         FHR       FIRE HOSE REEL
coordinate fixtures, fittings and dimensions.                                               to have FC substrate.                                                                                                                                                                       FIP       FIRE INDICATOR PANEL
All dimensions and levels are to be checked on site before fabrication.                                                                                                                                                                                                                 FP        FIREPLACE
All dimensions are to the face of structure of walls unless noted otherwise                 INTERNAL PAINTING: Unless noted otherwise paint system to be Dulux approved 3 coat                                                                                                          FRL       FIRE RESISTANCE LEVEL
Apply proprietary materials and components to the manufacturer's specification              system - low sheen finish. Colours to be confirmed by client and applied as per Dulux's                                                                                                     FW        FLOOR WASTE
Do not scale drawings. Scale correct at A1                                                  recommendations and guidelines.                                                                                                                                                             FX        FIXTURE
Dimensions are in millimeters unless otherwise noted                                                                                                                                                                                                                                    GAL       GALVANISED
                                                                                            ENERGY EFFICIENCY: all works to be in accordance with BCA Environmental Guidelines and                                                                                                      GR        GROUND FLOOR
SITE PLAN NOTES                                                                             approved energy efficiency report and ESD consultant certificates if applicable.                                                                                                            GL        GLASS
SURFACE WATER DRAINAGE MUST BE PREVENTED FROM ENTERING THE                                                                                                                                                                                                                              GPO       GENERAL PURPOSE OUTLET
BUILDING WITH FGL SLOPING AWAY FROM THE BUILDING AND FINISHED SLAB                          SMOKE ALARMS: Interconnected Photoelectric smoke alarms to be in accordance with part                                                                                                       GS        GAS OUTLET
LEVELS.                                                                                     3.7.2 of the BCA and AS 3786 to be hard wired to consumer supply with battery backup.                                                                                                       HP        HYDRAULIC PENETRATION
                                                                                            Positioning to comply with regulations to electrical spec.                                                                                                                                  HW        HOT WATER
SETOUT                                                                                                                                                                                                                                                                                  HYD       HYDRAULIC
FIGURED DIMENSIONS ARE ONLY TO BE TAKEN FROM THIS DRAWING. ALL                                                                                                                                                                                                                          MAX       MAXIMUM
DIMENSIONS, BEARINGS, EXISTING SERVICES, MANDATORY COUNCIL                                  GLAZING CONSTRUCTION                                                                                                                                                                        MECH      MECHANICAL
RESTAINTS/ REQUIREMENTS AND PROPOSED LEVELS ARE TO BE CHECKED                               POWDERCOATED ALUMINIUM FRAME WINDOWS IN ACCORDANCE WITH AS4055 'WIND                                                                                                                        m         METRES
AND VERIFIED ON SITE BY BUILDER PRIOR TO COMMENCEMENT OF WORKS.                             LOADS FOR RESIDENTIAL' AND AS 1288 'GLASS IN BUILDINGS SELECTION AND                                                                                                                        m2        SQUARE METRES
ALL DISCREPENCIES MUST BE COMMUNICATED TO THE DESIGNER PRIOR TO                             INSTALLATION                                                                                                                                                                                m3        CUBIC METRES
COMMENCEMENT OF WORKS. CONTRACTOR TO CONFIRM EXACT SITING AND                                                                                                                                                                                                                           MDF       MEDIUM DENSITY FIBREBOARD
ORIENTATION PRIOR TO CONSTRUCTION SETOUT. ALL BUILDING SETOUT,                              ALL WINDOWS TO BE VERIFIED AGAINST FLOOR PLANS AND ELEVATIONS BY                                                                                                                            mm        MILLIMETRES
CONFIRMATION OF SETBACKS AND HEIGHT TO BE CARRIED OUT BY A                                  CONTRACTOR. DISCREPENCIES TO BE REPORTED TO DESIGNER PRIOR TO                                                                                                                               MIN       MINIMUM
LICENSED SURVEYOR. ANY DISCREPENCIES TO BE RAISED WITH ARCHITECT                            COMMENCEMENT.                                                                                                                                                                               MS        MILD STEEL
                                                                                                                                                                                                                                                                                        MSB       MAIN SWITCH BOARD
ALL SLAB LEVELS TO BE VERIFIED PRIOR TO COMMENCEMENT.                                       WATERPROOFING: ALL WET AREAS AND WALLS TO BE WATERPROOFED IN                                                                                                                                NCC       NATIONAL CONSTRUCTION CODE
DISCREPENCIES ARE TO BE REPORTED TO THE DESIGNER. NOMINATED                                 ACCORDANCE WITH THE BCA 3.8 & AS 3740. BUILDER TO PROVIDE CERTIFICATE OF                                                                                                                    OSD       ONSITE STORMWATER DETENTION TANK
HARDSCAPING/LANDSCAPING ITEMS SUCH AS                                                       INSTALLATION AND COMPLIANCE                                                                                                                                                                 PB        PLASTERBOARD
DRIVEWAYS/PATHS/GARDENS/RETAINING ETC ARE DESIGN SUGGESTIONS                                                                                                                                                                                                                            PF        PAINT FINISH
ONLY.                                                                                       ALL DAMP PROOFING TO COMPLY WITH BCA CLAUSE F1.9, F1.10 AND AS/NZS 2904 AND                                                                                                                 PFC       PARALLEL FLANGE CHANNEL
                                                                                            AS2870                                                                                                                                                                                      PIR       POLYISOCYANURATE PANEL
ENGINEERING NOTES:                                                                                                                                                                                                                                                                      R         RADIUS
REFER TO ENGINEERS DETAILS FOR: FOOTINGS, SLAB, TIEDOWN, BRACING,                           CLIMATE CODE REQUIREMENTS                                                                                                                                                                   RL        RELATIVE LEVEL AHD
FRAMING SCHEDULE, FLOOR CONSTRUCTION, ROOF FRAMING AND TRUSS                                ENERGY EFFICIENCY ASSESSOR TO CONFIRM ADEQUACY OF PROPOSED                                                                                                                                  RWH       RAINWATER HEAD
DETAILS, WIND CATERGORY, POOL AND RETAINING WALLS. UNLESS                                   CONSTRUCTION. PROVIDE INSULATION TO NCC CODE REQUIRMENTS AND ENERGY                                                                                                                         RWO       RAINWATER OUTLET
OTHERWISE NOTED, ALL EXPOSED STRUCTURAL STEEL, ANCHOR BOLTS AND                             EFFICIENCEY REPORT                                                                                                                                                                          SE        STRUCTURAL ENGINEERING ITEM
OTHER ATTACHMENTS SHALL BE HOT DIP GALVANISED. CHECK ALL                                                                                                                                                                                                                                SHS       SQUARE HOLLOW SECTION
DIMENSIONS ON SITE PRIOR TO FABRICATION OF STEEL WORK                                       EROSION CONTROLS: ALL BUILDING WORKS TO COMPLY WITH LOCAL AUTHORIRIES                                                                                                                       SP        SPEC
                                                                                            EROSION AND SEDIMENT CONTROL STANDARDS                                                                                                                                                      SSL       STRUCTURAL SLAB LEVEL
SLAB AND FOOTINGS                                                                                                                                                                                                                                                                       ST        STONE
ALL SLAB AND FOOTINGS TO STRUCTURAL ENGINEERS DETAILS. A                                    STORMWATER NOTE                                                                                                                                                                             TL        TILE
POLYETHYLENE MOISTURE BARRIER SHALL BE LAPPED 200mm AND FULLY                               ALL STORMWATER DRAINAGE TO BE IN ACCORDANCE WITH NOOSA COUNCIL                                                                                                                              TM        TIMBER
TAPED UNDER ANY HABITABLE CONCRETE SLAB AND SHALL EXTEND 100mm                              GUIDELINES TO MINIMISE ERIOSION AND SCOURING. STORMWATER FLOR OTHER THAN                                                                                                                    TP        TAPWARE
ONTO THE PERIMETER FOOTING                                                                  NATURAL OVERLAND FLOW SHALL NOT BE DISCHARGED ONTO NEIGHBOURING                                                                                                                             TYP       TYPICAL
                                                                                            PROPERTY                                                                                                                                                                                    UA        UNIVERSAL ANGLE
WALL CONSTRUCTION                                                                                                                                                                                                                                                                       UB        UNIVERSAL BEAM
WALL FRAMING TO BE CONSTRUCTED IN ACCORDANCE WITH ENGINEERING                               ALL STORMWATER DRAINS TO BE 100mmØ UVPC SEALED SYSTEM IN ACCORDANCE                                                                                                                         UC        UNIVERSAL COLUMN
SPECIFICATION AND NOT DIFFER FROM CERTIFICATION COVERED BY THE                              WITH A.S. 3500.3 TO DISPERSE 170m2 MAX ROOF AREA. ALL STORMWATER DRAINAGE                                                                                                                   UPS       UNINTERRUPTED POWER SUPPLY
FORM 15. CLADDING SYSTEMS TO BE FIXED IN ACCORDANCE WITH                                    DESIGN IS PRELIMINARY AND TO BE CONFIRMED BY A LICENCED HYDRAULICS                                                                                                                          U/S       UNDERSIDE
MANUFACTURERS SPECIFICATION                                                                 DESIGNER                                                                                                                                                                                    WC        TOILET
                                                                                                                                                                                                                                                                                        WPM       WATER PROOF MEMBRANE
WET AREAS                                                                                   SEWER LINE LOCATION TO BE IDENTIFIED AND CONFIRMED BEFORE WORKS BEGIN                                                                                                                       WT        WALL TYPE
FLOORS IN 'WET AREAS' TO BE IMPERVIOUS IN ACCORDANCE WITH
AUSTRALIAN STANDARDS. FINISH AND FALL GRADIENTS TO FLOOR WASTES.                            TERMITE PROTECTION: TERMITE PROTECTION BY MEANS OF A TERMIMESH S.S. MESH
                                                                                            PHYSICAL BARRIER IN ACCORDANCE WITH A.S.3660 1/2000 AND BCA AND INSTALLED IN                                                                                                                MATERIALS, FINISHES AND FIXTURES CODES
SEAL WET AREAS IN ACCORDANCE WITH NCC VOL 2 PART 3.8.1 SLOPE FLOOR                          STRICT ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS.                                                                                                                                        TO BE READ IN CONJUCTION WITH FIXTURES AND
SURFACE TOWARDS FW (FLOOR WASTES)                                                                                                                                                                                                                                                       FINISHES SCHEDULES. FINISHES AND FIXTURES TO
                                                                                                                                                                                                                                                                                        INTERIOR DESIGNERS DETAILS
TOILETS: MINIMUM 3 STAR WELS RATED FOR KITCHEN SINKS, BASINS AND                            POOL FENCE
LAUNDRY TROUGHS                                                                             POOL FENCING AND GATES IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS
                                                                                            AND A.S. 1926.1 LOCATION TO BE CONFIRMED ON SITE WITH BUILDER/CLIENT
SHOWERHEADS: MINIMUM 3-STAR WELS RATED SHOWER HEADS
                                                                                            LICENSED TRADESPERSONS: ALL SERVICES TO BE INSTALLED BY LICENSED                                                                                                                                                                                                                                 CLIENT:
                                                                                            TRADESPERSONS IN ACCORDANCE WITH LOCAL AUTHORITY AND WITH CURRENT
                                                                                            MANUFACTURERS SPECIFICATIONS.
                                                                                                                                                                                                                                                                                                                                                                                                 ANDREW + ANDREA MACLAREN



                                                                                                                                                                                                                                                                                                                                                                                             PROJECT:


                                                                                                                                                                                                                                                                                                                                                                                                 CNR KESTREL CRES & LORILET ST



                                                                                                                                                                                                                                                                                                                                                                                             ARCHITECT:




                                                                                                                                                                                                                                                                                                                                                                                                                                                                  M. 0475 030 630
                                                                                                                                                                                                                                                                                                                                                                                                                                                                  W. honghenwood.com
                                                                                                                                                                                                                                                                                                                                                                                                                                                                  E. [email protected]
                                                                                                                                                                                                                                                                                                                                                                                                                                                                  ABN No. 12822847278


                                                                                                                                                                                                                                                                                                                                                                                             DRAWING TITLE:



                                                                                                                                                                                                                                                                                                                                                                                             PROJECT NOTES


                                                                                                                                                                                                                                                                                                                                                                                             NOTES:                                                                         NORTH:

                                                                                                                                                                                                                                                                                                                                                                                             1. Use only figured dimensions, do not scale drawings.
                                                                                                                                                                                                                                                                                                                                                                                             2. All discrepancies and omissions to be referred to Hong Henwood
                                                                                                                                                                                                                                                                                                                                                                                             Design prior to construction.
                                                                                                                                                                                                                                                                                                                                                                                             3. Check all dimensions, Building Code of Australia, relevant codes
                                                                                                                                                                                                                                                                                                                                                                                             and council approvals.
                                                                                                                                                                                                                                                                                                                                                                                             4. This drawing is not for construction.
                                                                                                                                                                                                                                                                                                                                                                                             Copyright remains the property of Hong Henwood. Reproduction of the
                                                                                                                                                                                                                                                                                                                                                                                             whole or part of this document constitutes an infringement of copyright.
                                                                                                                                                                                                                                                                                                                                                                                             5. Nominated Architect: Karen Leech QLD 5795




                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   20/09/2023 4:36:24 PM
                                                                                                                                                                                                                                                                                                                                                                                             SCALE:                                                                         DATE:

                                                                                                                                                                                                                                                                                                                                                                                                 1 : 50                            @ A1                                     11/08/23
                                                                                                                                                                                                                                                                                                                                                                                             DRAWN BY:                CHECKED BY:               PROJECT NO:                 DRAWING NO:   ISSUE:

                                                                                                                                                                                                                                                                                                                                                                                                    KL                       HH                   2216
                                                                                                                                                                                                                                                                                                                                                                                             CAD FILE:                                                                       A0002         A
Log in to download the original file

221363 - 2 Kestrel Cres Peregian Beach - Construction of Dwelling, Swimming Pool & Fence - Stamped - Archs.pdf · 5.5 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.