    Performance Outcome                 Acceptable Outcome                       Response

 PO7 Buildings, structures and      AO7.2 Buildings and structures     The proposed rooftop terrace
 landscaping are consistent with    do not include rooftop terraces.   includes a small pool and pool
 and reflect the beachside                                             terrace area that is nestled
 character of the local plan area                                      within a green roof. Refer to
 in terms of form, composition                                         elevations and roof plan for
 and use of materials.                                                 form, composition and use of
                                                                       materials. The local area and
                                                                       adjoining      sites      include
                                                                       substantial roof terraces.

5.5 DUAL OCCUPANCY AND MULTIPLE DWELLING CODE

The purpose of the Dual Occupancy and Multiple Dwelling Code is to ensure dual occupancy and
multiple dwellings are of a high quality design which appropriately respond to local character,
environment and amenity considerations.

Response: A code assessment has been submitted with this application. The proposal is considered
to achieve compliance, or can achieve compliance, with the code, with the exception of the
acceptable outcomes below:


    Performance Outcome                 Acceptable Outcome                       Response

PO5 Development is designed AO5 Bedroom windows are at                 The Bed 2 window in Unit 1 is
to minimise noise carrying least 3 metres away from shared             sited adjacent to the vehicular
between dwelling units or driveways, car parking areas,                driveway, albeit it is noted that
accommodation units by locating mechanical plant, refuse and           this wall faces perpendicular to
noise sensitive spaces such as recycling areas, vents and              the driveway, and is screened
bedrooms away from noise exhausts.                                     by a wall and courtyard.
generating     areas     of the
development, such as car
parking areas or mechanical
plant    and      equipment  or
recreational facilities.


5.6 PLANNING SCHEME OVERLAYS
The below table addresses the applicable overlays relating to the development site:


                      Overlay                                             Comment

                                          Landslide Hazard




                                                                                                     21

Log in to download the original (Town Planning Assessment Report.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.