                                                                               ABN 46 326 883 383

  Please refer to the enclosed Tim Ditchfield Architects Plans Ref: 2104 dated Nov 2021
  and the below area of non-compliance.

     AO12.1 – Setbacks
        o The pool is approx. 1.140m above NGL and therefore does not comply with
           the required 6m setback to rear boundaries. It is noted that the affected
           property to the rear is zoned Environmental Management and Conservation.

         o The proposed eastern side boundary fencing exceeds 2.0m when measured
           from NGL (~3.6m proposed – new block wall and planter with rendered light
           weight wall over the sewer). It is noted that the fencing height measured from
           the suspended tiled terrace totals 2.5m

         o The proposed western side boundary fencing exceeds 2.0m (2.6m inc trellis)
           however this fence is not being altered as part of these works. This boundary
           fence adjoins the private access road described as lot 0 on SP190823

         o The 1.2 frameless glass balustrade on the western edge of the suspended
           slab and on the northern boundary exceeds 2.0m when measured from
           natural ground (2.4m proposed)

         o Construction of new stairs to tiled terrace located 0.8m from the western side
           boundary in lieu of 1.5m for structures above 1m in height.

     AO10/11 – Site Cover/Plot Ratio
        o The proposed works are more than 1m above ground and therefore
           constitute site cover and exceed the permitted 40% site cover and/or 0.4:1
           plot ratio

  By way of justification for the above areas of non-compliance, PO12 of the Medium
  Density Residential Zone Code is addressed below:

      a) The proposed works increases amenity levels for the subject site and are
         consistent with the already completed works at the adjoining property, therefore
         amenity levels of the adjoining property will not be adversely affected.
      b) The proposed works will not increase instances of overlooking or obstruct any
         views.
      c) The site adjoins a non-residential zoned land to the rear which ensures sufficient
         separation from adjoining land uses.
      d) The proposed works include the removal of vegetation within private property
         only. No works are proposed in the Environmental zoned land to the rear.
      e) The plans include a planter bed on the eastern boundary and retention of
         existing planting at natural ground level around the sewer on the western
         boundary.
      f) The proposed works are considered to be consistent with adjoining
         development as they are matching the approved pool and fencing located at
         2/35 Viewland Dr.
      g) The proposed works will not create any adverse impacts to ecologically
         sensitive areas.

(07) 5451 0579                                                     1/24 Wirraway Street
0421 053 173                                                       Alexandra Headland QLD 4572
[email protected]                                 PO Box 1632
www.purebuildingapprovals.com.au                                   Buderim QLD 4556
Log in to download the original file

GIA Justification Letter - 1 35 viewland (2).pdf · 348 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.