compatible with surrounding
development;

b) does not present an appearance of bulk
to adjacent properties, roads or other
areas in the vicinity of the site:

c) maximises the retention of existing
vegetation and allows for additional soft
landscaping between buildings;

d) — allows for adequate area at ground level
for outdoor recreation, entertainment,
clothes drying and other site facilities;
and

e) facilitates onsite stormwater
management and vehicular access.

010 Site cover does not exceed—

a) for the Detached Housing Zone—50% for
a single storey building and 40% for a
double storey building;

b) for the Semi-attached Housing Zone—
40%; or

c) for the Attached Housing Zone—40%

011 For Multiple Housing Type 2 buildings
have a maximum plot ratio of 0.45:1.

012 For Multiple housing Type 3 or 4, Visitor
accommodation Type 4, or the
accommodation unit component of an
Entertainment and dining business Type
3—maximum gross floor area is
equivalent to the maximum allowable
population in persons multiplied by 40m2.

013 For the Business Centre Zone plot ratio
does not exceed—

a) 0.8:1 for site areas up to and including
2,000m2; and

b) 0.3:1 for the balance of a site over
2,000m2.

 

 

Flooding and drainage’ The subject property is not considered to be
014 Buildings and other works are designed at risk of flooding.
and sited to—

a) provide flood free access to premises
and flood free habitable areas;

b) allow only minor, short term and
infrequent flooding of non-habitable
areas;

c) ensure drainage does not adversely
impact upon other premises; and

d) ensure filling or excavation does not
adversely impact upon other premises
by—

i. Causing ponding of water on the
site or nearby land;

ii. increasing flooding, which
adversely affects the safety or

 

The site already has an appropriate gradient
to allow for drainage. Each of the concrete
pads for the accommodations sites will be
sloped to allow for water to drain. This
proposal is not expected to significantly
increase the area of non-permeable
surfaces as compared to the existing
development on the site.

 

 

 

Used in these records

About this file

File size
12.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Planning Report 3461.pdf · 12.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.