Council archive · source document
Amended Plans · 172007.545.02
Plans and drawings: the text below has words only, no drawings.
BUILDING WORKS DRAWING SET
SETOUT .
SERIES 100 SITE PLANS
Building Works to be setout by Licensed .
Surveyor. WD.101 COVER SHEET
Identification and height verification survey to SERIES 200
.
FLOOR PLANS
be carried out once fascia/gutter and ridge to WD.201 EXISTING LOWER LEVEL FLOOR PLAN
roof has been erected to confirm no works WD.202 EXISTING GROUND FLOOR PLAN suite 2
WD.203 EXISTING UPPER LEVEL FLOOR PLAN 46 mary street
encroach boundaries and the building has noosaville qld 4566
been constructed in accordance with WD.204 EXISTING ROOF PLAN
approved plans and height does not exceed WD.205 PROPOSED GROUND FLOOR PLAN 12°00' po box 613
9.0m height limit as per the local planning WD.206 PROPOSED UPPER LEVEL FLOOR PLAN 20.117 noosa heads qld 4567
scheme. WD.207 PROPOSED ROOF PLAN 32.00 1.5m setback
2.0m setback telephone 07 54473255
GENERAL NOTES
facsimile 07 54473299
SERIES 400
.
ELECTRICAL PLANS
WD.401 EXISTING ELECTRICAL PLANS inf [email protected]
Toilet doors are to open outwards or be fitted with WD.402 EXISTING ELECTRICAL PLANS
lift off hinges in accordance with part 3.8.3.3 of WD.403 EXISTING ELECTRICAL PLANS www.ct-design.com.au
33.00
BCA Housing Provisions. WD.404 PROPOSED ELECTRICAL PLANS
2.5m setback
2.0m setback
1.5m setback
2.5m setback
1.5m setback
2.0m setback
existing building designer licence 1016347
WD.405 PROPOSED ELECTRICAL PLANS 950 Pool + Deck
All glazing in buildings to comply with the WD.406 PROPOSED ELECTRICAL PLANS extension (approx. location) This drawing is to be read in
requirements of part 3.6 of BCA2006 Housing conjunction with Engineers Drawings
5,306
Provision and AS1288/2005. A glazing certificate SERIES 500 ELEVATIONS
1,057 & Reports.
from the manufacturer for compliance with 34.00
Construction to comply with all
.
fall
AS1288 must be provided on completion. WD.501 EAST ELEVATIONS existing
relevant SAA & BCA Codes &
Upper Level proposed
WD.502 NORTH ELEVATIONS Awning standard Bldg By-law 1975 & as
Terrace
All Balustrading to Decks shall be engineer WD.503 WEST ELEVATIONS amended.
WD.504 SOUTH ELEVATIONS
101°54'10"
101°54'10"
certified. Verify all dimensions on site prior to
30.175
30.175
35.00 commencement of any works. These
Builder to allow for disposal from site all waste SERIES 600 SECTIONS drawings are not to be used for
scaling. Copyright for design &
.
materials during demolition and construction WD.601 SECTION A drawings remain the property of
existing
period. RESIDENCE the authors.
SERIES 700 DETAILS
CONSULTANTS
.
Smoke alarms must comply with AS 3786 and be WD.701 BALUSTRADE DETAIL 36.00
.
connected to the consumer mains power. Smoke WD.702 BALUSTRADE DETAIL Structural Engineer
alarms must be located in accordance with part
.
WD.703 TYPICAL COLUMN DETAIL SCG Consulting Engineers
3.7.2.3 of the building code of Australia. Contact: Matt 07 5455 5604
[email protected]
SERIES 800 JOINERY 37.00 .
Surveyor
.
WD.801 ENSUITE
TERMITE PROTECTION WD.802 ENSUITE
.
Hass Survey
Contact: Phil Hass 0421 039 204
The building shall be protected from WD.803 LAUNDRY existing
[email protected]
Entry Court
subterranean termites by approved physical
.
6.0m setback Building Certifier
and/ or chemical barriers in accordance with SERIES 900
.
SCHEDULES .
Suncoast Building Approvals
AS3660.1. WD.901 DOOR SCHEDULE Contact: 07 5443 7288
existing existing [email protected]
The precise method of protection shall be existing Driveway Off-Street
Garden Parking
determined by the owner/ s and/ or builder
only after consultation with a licensed pest REAL PROPERTY
control operator.
DESCRIPTION 20.117
12°00'
C2 Issued for Construction
Revised 05.05.2021
This information then shall be advised to the
.
LOT No. 78 for Lodgement of Variation
Local Government or Licensed Certifier prior AREA 607sq/m Project
to, or at the time of lodgement of the Building COUNTY March PROPOSED
Permit Application. PARISH Weyba
A R K A N A D R I V E
RENOVATION
COUNCIL Noosa Location
Thereafter, the owners shall ensure that any
physical barriers are kept clear of garden beds 25 ARKANA DR
and/ or soil build up, that any chemical STORMWATER NOOSA HEADS Q
barriers remain undisturbed and that annual Roof & surface stormwater to be disposed of in SITE PLAN 1:200 Client
inspections (plus eradication as necessary ) accordance with local authority requirements F & R SANDERS
are carried out thoughout the life of the Drawing Title
building by a licensed pest control operator in
accordance with AS3660.1. WATER PROOFING COVER SHEET
On the completion of the building prior to the WET AREAS ROOFWATER DISCHARGE TO:
Existing Approved System
Scale Date
final inspection by the licensed Building Waterproofing of wet areas to comply with as shown @A3 2020
Certifier, a licensed Pest Controller is to AS3740-2004. A certificate including •Stormwater to be discharged so as to not cause Drawn By Job No:
inspect and confirm that the termite system bathrooms, WC and laundry from an erosion or nuisance to adjoining properties SC 2010
installed has not been bridged or breached approved waterproofing applicator will be •Stormwater system to comply with AS3500 Part 3
Drawing No. Issue No.
and the required visual barrier has been required before a final certificate can be •All other details to Local Government Requirements
maintained. issued. WD.101 C2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of pages 2 to 14 (of 17)
Page 2
13,050
290 2,710 70 5,360 550 70 530 70 3,110 290
240 6,330 200 900 200 4,940 240
290 3,963 290 3,963 290 3,963 290 910 suite 2
46 mary street
noosaville qld 4566
po box 613
noosa heads qld 4567
80
80
telephone 07 54473255
290
290
facsimile 07 54473299
existing
1,850
1,850
1,850
1,850
1,850
LOWER LEVEL DECK inf [email protected]
1,480
1,480
timber
www.ct-design.com.au
240
240
building designer licence 1016347
240
240
1,020
UP
1,920
1,670
t This drawing is to be read in
ex.L'DRY conjunction with Engineers Drawings
ex.tiles
70
tub existing existing & Reports.
wm
4,110
3,670
3,670
3,670
70
LIVING 2 BED 4 Construction to comply with all
ex.BATH ex.tiles ex.carpet
940
wc relevant SAA & BCA Codes &
robe
2,580
b
ex.tiles
standard Bldg By-law 1975 & as
70
amended.
linen
920
shr
Verify all dimensions on site prior to
commencement of any works. These
1 drawings are not to be used for
200
200
200
200
2 scaling. Copyright for design &
3 drawings remain the property of
4 the authors.
5
3,500
3,300
6
CONSULTANTS
.
UP Structural Engineer
.
SCG Consulting Engineers
Contact: Matt 07 5455 5604
[email protected]
200
200
.
Hass Survey
Contact: Phil Hass 0421 039 204
[email protected] Certifier
.
Suncoast Building Approvals
Contact: 07 5443 7288
[email protected]
C2 Issued for Construction
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
RENOVATION
Location
25 ARKANA DR
NOOSA HEADS Q
Client
NO BUILDING WORKS REQUIRED TO LOWER LEVEL F & R SANDERS
Drawing Title
EXISTING LOWER
N
LEVEL FLOOR PLAN
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
EXISTING LOWER LEVEL - DEMOLITION FLOOR PLAN 1:100
WD.201 C2
Page 3
13,050 1,700
240 3,720 90 3,650 90 5,020 240 1,700
240 3,720 90 3,650 90 1,055 2,620 1,345 1,700
240 1,700 70 1,950 90 1,860 90 1,700 90 3,010 90 2,070 90 1,610 90
laundry
suite 2
90 650 390 46 mary street
noosaville qld 4566
study nook
po box 613
noosa heads qld 4567
370
290
telephone 07 54473255
facsimile 07 54473299
existing
1,850
1,770
GROUND FLOOR PATIO inf [email protected]
1,480
1,480
tile
240
240
UP
www.ct-design.com.au
ex. building designer licence 1016347
240
240
1,400240
240
240
t L'DRY
laundry
1,400
remove existing 'laundry' remove existing double doors, This drawing is to be read in
walls, joinery & plumbing, wm conjunction with Engineers Drawings
existing & prepare for single hinged door
& make good & Reports.
3,050
existing BED 1
90
90
4,300
3,870
BED 2 ex.carpet Construction to comply with all
4,060
remove existing 'study nook'
4,470
relevant SAA & BCA Codes &
study nook
joinery, & prepare for new existing remove existing low wall,
standard Bldg By-law 1975 & as
2,325
2,325
STUDY posts (2no.) & electrical wiring,
low wall/post
120
NOOK & make good amended.
cut back existing walls,
& prepare for new laundry remove existing vanity & plumbing Verify all dimensions on site prior to
890
70 70
fittings & prepare for new commencement of any works. These
90
drawings are not to be used for
650
90
90
530
robe scaling. Copyright for design &
90
existing drawings remain the property of
1,390
existing remove existing spa & plumbing fittings,
9,820
70
ENS spa bath
1,000
ex.WC 8 prepare area for new shower recess the authors.
WIR
ensuite
b ex.tile
U
2,460
7
P
ex.carpet
6
CONSULTANTS
11,950
70
5 7 shr
70
existing WC to remain .
1,000
4 8
9 ex.W C wc Structural Engineer
3,880
3
13,650
existing 10 remove all existing floor
.
2,140
2 SCG Consulting Engineers
5,915
5,915
BATH 1 11 & wall tiles, wall mirrors Contact: Matt 07 5455 5604
90
90
12 & fittings, & prepare new [email protected]
UP 13 .
70 600 70
remove existing shower Surveyor
.
existing recess, screen & plumbing Hass Survey
robe
fittings & prepare area for Contact: Phil Hass 0421 039 204
ENTRY new
9,350
[email protected]
70
1 .
2 Building Certifier
.
3 Suncoast Building Approvals
existing UP 4 existing Contact: 07 5443 7288
2,980
2,980
6,620
6,620
BED 3 GARAGE [email protected]
1,800 90
1,800 90
ex.concrete
C2 Issued for Construction
240
240
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
90
90
RENOVATION
Location
25 ARKANA DR
240 2,650 70 1,000 90 2,660 90 900 90 3,010 90 2,070 90 1,610 90
NOOSA HEADS Q
Client
240 2,650 70 1,000 90 3,330 90 7,190 90
F & R SANDERS
240 3,720 240 3,180 90 7,190 90 Drawing Title
4,200 3,180 7,370 EXISTING GROUND
N
14,750 FLOOR PLAN
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
EXISTING GROUND FLOOR - DEMOLITION PLAN 1:100
WD.202 C2
Page 4
suite 2
46 mary street
noosaville qld 4566
13,050
po box 613
noosa heads qld 4567
140 5,060 7,800 50 telephone 07 54473255
ex.awning over
facsimile 07 54473299
140 5,060 50 2,820 50 2,830 50 1,950 50 50
inf [email protected]
ex.column ex.column ex.column ex.column
to be removed to be removed to be removed to be removed www.ct-design.com.au
existing awning columns building designer licence 1016347
(4 of 4) to be removed
This drawing is to be read in
190
ex.gutter below to remain conjunction with Engineers Drawings
ex. column
& Reports.
150
Construction to comply with all
relevant SAA & BCA Codes &
standard Bldg By-law 1975 & as
remove existing fabric awning amended.
(over), refer to Existing Roof Plan
existing balustrade Verify all dimensions on site prior to
5,810
to Upper Level Terrace existing commencement of any works. These
5,810
to be removed UPPER LEVEL TERRACE existing balustrade drawings are not to be used for
5,470
concrete to Upper Level Terrace scaling. Copyright for design &
to be removed drawings remain the property of
the authors.
remove existing
external rangehood CONSULTANTS
& make good .
Structural Engineer
existing awning beam external .
rangehood SCG Consulting Engineers
within roof diaphragm over
to be removed Contact: Matt 07 5455 5604
[email protected]
90
90
90
15
14
13
.
12
11
remove existing UP remove existing window Surveyor
10
9
.
water damaged ceiling blind pelmets (3no.)
& make& good
make good
8
7 Hass Survey
2,620
(extent indicated in red) 6 existing
Contact: Phil Hass 0421 039 204
2,990
& make good DINING [email protected]
ex.timber .
Building Certifier
.
existing 1 Suncoast Building Approvals
2
LIVING Contact: 07 5443 7288
120
3
6,370
ex.carpet [email protected]
4
UP
7,820
7,820
C2 Issued for Construction
4,900
4,650
existing Revised 05.05.2021
LIGHT for Lodgement of Variation
WELL Project
70
(over) existing
KITCHEN PROPOSED
ex. RENOVATION
1,200
ex.timber
WC ex.PDR
ex.tile Location
25 ARKANA DR
90
90
90
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
EXISTING UPPER
N
LEVEL FLOOR PLAN
Scale Date
230 1,860 70 920 70 3,920 70 5,820 90 as shown @A3 2020
13,050 Drawn By Job No:
SC 2010
Drawing No. Issue No.
EXISTING UPPER LEVEL - DEMOLITION PLAN 1:100
WD.203 C2
Page 5
13,050
5,200 7,800 50
existing awning suite 2
46 mary street
140 5,060 50 2,820 50 2,830 50 1,950 50 515 noosaville qld 4566
ex.column/beam ex.column/beam ex.column/beam ex.column/beam po box 613
to be removed to be removed to be removed to be removed noosa heads qld 4567
existing awning columns (4 of 4) line of existing terrace slab below
to be removed telephone 07 54473255
facsimile 07 54473299
190
190
inf [email protected]
existing awning beams (4 of 4)
& cross members, existing fabric awning
to be removed www.ct-design.com.au
to be removed
building designer licence 1016347
awning structure
4,840
existing This drawing is to be read in
5,620
AWNING fall conjunction with Engineers Drawings
& Reports.
Construction to comply with all
relevant SAA & BCA Codes &
standard Bldg By-law 1975 & as
amended.
existing awning beam Verify all dimensions on site prior to
within roof diaphragm commencement of any works. These
to be removed drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
CONSULTANTS
.
existing Structural Engineer
ROOF fall
.
SCG Consulting Engineers
ex.colorbond Contact: Matt 07 5455 5604
[email protected] Survey
Contact: Phil Hass 0421 039 204
[email protected]
fall .
Building Certifier
.
existing existing Suncoast Building Approvals
LIGHT LIGHT WELL Contact: 07 5443 7288
WELL ROOF [email protected]
(void) ex.colorbond
C2 Issued for Construction
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
RENOVATION
Location
25 ARKANA DR
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
EXISTING ROOF
N
PLAN
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
EXISTING ROOF - DEMOLITION PLAN 1:100
WD.204 C2
Page 6
13,050 1,700
240 3,720 90 3,650 90 5,020 240 1,700
240 3,720 90 3,650 90 1,055 2,620 1,345 1,700
240 1,700 70 1,950 90 1,860 90 1,700 90 3,010 90 2,070 90 1,610 90
suite 2
90 650 390 46 mary street
noosaville qld 4566
po box 613
noosa heads qld 4567
370
290
telephone 07 54473255
facsimile 07 54473299
existing
1,850
1,770
GROUND FLOOR PATIO inf [email protected]
1,480
1,480
new carpet to Bedroom & WIR,
tile
240
UP
'By Client' www.ct-design.com.au
building designer licence 1016347
240
240
240
240
240
Waterproofing in accordance
1,400
new floor tiles with AS3740 required to This drawing is to be read in
to match existing laundry and ensuite conjunction with Engineers Drawings
& Reports.
3,050
existing d proposed
90
4,300
3,870
CD
BED 2 proposed Construction to comply with all
4,060
wm
BED 1 new wall infill to match existing,
4,470
L'DRY relevant SAA & BCA Codes &
t new carpet paint finish as spec standard Bldg By-law 1975 & as
2,325
D01
120
new laundry plumbing king size
new hinged door, amended.
& joinery, as specified refer to Door Schedule
new nib walls (2no.), Verify all dimensions on site prior to
new floor tiles,
890
linen
70 70
to match existing commencement of any works. These
90
as specified drawings are not to be used for
90
530
robe new nib wall to shower, scaling. Copyright for design &
90
tiled as specified drawings remain the property of
1,390
existing
9,820
70
1,000
ex.WC 8 proposed the authors.
WIR b shower new glass shower screen/door,
U
2,460
7
P
new carpet ENSUITE as specified
6
CONSULTANTS
11,950
70
5 7 new tile
new shower rose & mixer,
70
.
1,000
4 8
b ex.W C wc Structural Engineer
9 as specified
3,880
3
13,650
existing 10 t/r .
2,140
2 new vanity with double basin SCG Consulting Engineers
5,915
BATH 1 11
& mixers, refer to Series 800 Contact: Matt 07 5455 5604
90
90
12
Joinery Drawings [email protected]
UP 13 .
70 600 70
Surveyor
.
robe existing Hass Survey
ENTRY Contact: Phil Hass 0421 039 204
9,350
[email protected]
70
1 .
2 Building Certifier
.
3 Suncoast Building Approvals
existing UP 4 existing Contact: 07 5443 7288
2,980
2,980
6,620
6,620
BED 3 GARAGE [email protected]
1,800 90
1,800 90
ex.concrete
C2 Issued for Construction
240
240
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
90
90
RENOVATION
Location
25 ARKANA DR
240 2,650 70 1,000 90 2,660 90 900 90 3,010 90 2,070 90 1,610 90
NOOSA HEADS Q
Client
240 2,650 70 1,000 90 3,330 90 7,190 90
F & R SANDERS
240 3,720 240 3,180 90 7,190 90 Drawing Title
4,200 3,180 7,370 PROP. GROUND
N
14,750 FLOOR PLAN
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
PROPOSED GROUND FLOOR PLAN 1:100
WD.205 C2
Page 7
line of proposed RHS fascia beam
over, refer to Engineering
line of proposed zip screen
cassette over, as spec proposed zip screen guide
Balcony waterproofing to
comply with AS4654.
Minimum 70mm vertical proposed frameless balustrade
as spec
upturn of membrane required ex.awning structural column suite 2
for an N3 wind classification 46 mary street
proposed zip screen guide noosaville qld 4566
13,050 line of proposed zip screen cassette po box 613
over, as spec
noosa heads qld 4567
line of proposed RHS beam
4,250 8,750 50 over, refer to Engineering telephone 07 54473255
Glass balustrades to new awning over
have interlinking proposed frameless balustrade facsimile 07 54473299
handrail or top rail 4,250 50 3,300 50 3,300 50 1,950 50 as spec
inf [email protected]
new column new column
ex. column ex. column
www.ct-design.com.au
new RHS awning columns (4no.) building designer licence 1016347
refer to Engineers design
This drawing is to be read in
190
190
awning columns
awning columns
refer to detail inset (above)
new frameless glass balustrade, conjunction with Engineers Drawings
& Reports.
new
new
refer to External Finishes Schedule
150
150
and WD.701/702 Balustrade Detail new zip track drop down sunscreens Construction to comply with all
to perimeter of awning structure (5no.), relevant SAA & BCA Codes &
new tiles to existing terrace slab, as specified standard Bldg By-law 1975 & as
refer to External Finishes Schedule
proposed amended.
new tiles to existing terrace slab,
UPPER LEVEL TERRACE
e
new awning over,
ng
refer to External Finishes Schedule Verify all dimensions on site prior to
5,810
ou
refer to Proposed Roof Plan new tiles commencement of any works. These
nl
new frameless glass balustrade,
5,810
su
drawings are not to be used for
5,470
5,470
new awning beams (over), lounge refer to External Finishes Schedule
rug scaling. Copyright for design &
e
refer to Engineers Design and WD.701/702 Balustrade Detail
ng
dining drawings remain the property of
ou
& Proposed Roof Plan lounge
the authors.
nl
new tiles new tiles
su
fall 1:100 fall 1:100
new zip track drop down sunscreens
to perimeter of awning structure (5no.), CONSULTANTS
as specified .
planters
Structural Engineer
step step provide water connection .
down down for future outdoor sink SCG Consulting Engineers
Contact: Matt 07 5455 5604
new awning beam [email protected]
90
90
90
15
14
13
(within roof diaphragm), .
12
11
UP Surveyor
10
refer to Engineers design
9
.
8
7 Hass Survey
2,620
6 existing
Contact: Phil Hass 0421 039 204
2,990
chair chair
DINING [email protected]
new finish to ex.timber .
Building Certifier
new finish to .
existing 1
existing timber floorboards Suncoast Building Approvals
2
LIVING 'By Client' Contact: 07 5443 7288
120
3
6,370
new carpet [email protected]
new carpet to Living 4
'By Client' UP
7,820
7,820
sofa
new finish to C2 Issued for Construction
tv
4,900
existing timber floorboards
4,650
existing Revised 05.05.2021
sofa 'By Client'
LIGHT for Lodgement of Variation
WELL Project
keyboard
70
(over) existing
PROPOSED
piano/
KITCHEN
ex. RENOVATION
1,200
new finish to ex.timber
WC ex.PDR
ex.tile Location
25 ARKANA DR
90
90
90
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
PROPOSED UPPER
N
LEVEL FLOOR PLAN
Scale Date
230 1,860 70 920 70 3,920 70 5,820 90 as shown @A3 2020
13,050 Drawn By Job No:
SC 2010
Drawing No. Issue No.
PROPOSED UPPER LEVEL FLOOR PLAN 1:100
WD.206 C2
Page 8
13,050
4,250 8,750 50
new awning suite 2
46 mary street
4,250 50 3,300 50 3,300 50 2,000 noosaville qld 4566
new zip sun screen new zip sun screen new zip sun screen
new new new new po box 613
new 50x150mm RHS fascia beam to full length column/beam column/beam column/beam column/beam noosa heads qld 4567
new zip track drop down sunscreens
of awning structure, refer to Engineering 950 to perimeter of awning structure,
extension as specified, refer to Series 700 Detail telephone 07 54473255
new RHS awning columns
facsimile 07 54473299
(4no. below),
190
190
190
190
refer to Engineers design
inf [email protected]
new zip track drop down sunscreens
red shading indicates awning coverage to perimeter of awning structure,
greater than existing awning www.ct-design.com.au
as specified, refer to Proposed Elevations
new awning structure
2deg fall
new RHS awning beams building designer licence 1016347
awning structure
(4no. below), new 50x150mm RHS beam below
new zip sun screen
new zip sun screen
4,840
4,840
refer to Engineers Design new (in line with awning beam), This drawing is to be read in
5,620
5,620
new 50x150mm RHS beam below AWNING refer to Engineering conjunction with Engineers Drawings
(in line with awning beam), & Reports.
refer to Engineering new zip screen cassette
fixed to RHS beam in a/w Construction to comply with all
new zip screen cassette manufacturers written instruction relevant SAA & BCA Codes &
fixed to RHS beam in a/w standard Bldg By-law 1975 & as
manufacturers written instruction amended.
new awning to top of awning structure new awning beam within roof diaphragm Verify all dimensions on site prior to
as specified refer to Engineering commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
CONSULTANTS
.
existing Structural Engineer
ROOF fall
.
SCG Consulting Engineers
ex.colorbond Contact: Matt 07 5455 5604
[email protected] Survey
Contact: Phil Hass 0421 039 204
[email protected]
fall .
Building Certifier
.
existing existing Suncoast Building Approvals
LIGHT LIGHT WELL Contact: 07 5443 7288
WELL ROOF [email protected]
(void) ex.colorbond
C2 Issued for Construction
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
RENOVATION
Location
25 ARKANA DR
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
PROPOSED ROOF
N
PLAN
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
PROPOSED ROOF PLAN 1:100
WD.207 C2
Page 9
site boundary
site boundary
suite 2
46 mary street
noosaville qld 4566
po box 613
noosa heads qld 4567
telephone 07 54473255
facsimile 07 54473299
inf [email protected]
www.ct-design.com.au
building designer licence 1016347
This drawing is to be read in
conjunction with Engineers Drawings
& Reports.
Construction to comply with all
relevant SAA & BCA Codes &
standard Bldg By-law 1975 & as
amended.
Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
EXISTING EAST ELEVATION 1:100
CONSULTANTS
.
Structural Engineer
.
SCG Consulting Engineers
NO BUILDING WORKS REQUIRED TO EASTERN FASCADE Contact: Matt 07 5455 5604
[email protected] Survey
Contact: Phil Hass 0421 039 204
[email protected]
site boundary
site boundary
.
Building Certifier
.
Suncoast Building Approvals
Contact: 07 5443 7288
[email protected]
C2 Issued for Construction
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
RENOVATION
Location
25 ARKANA DR
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
EAST ELEVATIONS
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
PROPOSED EAST ELEVATION 1:100 Drawing No. Issue No.
WD.501 C2
Page 10
site boundary
site boundary
existing awning beams
& cross-members
to be removed
suite 2
46 mary street
existing awning columns noosaville qld 4566
(4no.) to be removed
po box 613
noosa heads qld 4567
existing balustrade to
Upper Level Terrace
telephone 07 54473255
to be removed
facsimile 07 54473299
inf [email protected]
www.ct-design.com.au
building designer licence 1016347
This drawing is to be read in
conjunction with Engineers Drawings
& Reports.
Construction to comply with all
relevant SAA & BCA Codes &
standard Bldg By-law 1975 & as
amended.
Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
CONSULTANTS
EXISTING NORTH ELEVATION 1:100 .
Structural Engineer
.
SCG Consulting Engineers
Contact: Matt 07 5455 5604
[email protected]
site boundary
site boundary
new metal flashing/gable infill, .
refer to External Finishes Schedule Surveyor
.
new RHS beam, in line with beam over, refer to Hass Survey
Engineers Design Contact: Phil Hass 0421 039 204
[email protected] awning Building Certifier
to top of awning structure, .
refer to Proposed Roof Plan Suncoast Building Approvals
Contact: 07 5443 7288
new RHS fascia beam, refer to [email protected]
External Finishes Schedule
new zip track drop down sunscreens
dropdown to perimeter of awning structure (5no.),
zip screen
refer to Series 700 Detail
new frameless glass balustrade, C2 Issued for Construction
refer to Series 700 Detail Revised 05.05.2021
for Lodgement of Variation
NOTE: paint finish to new
steel awning structure, Project
(including columns, beams PROPOSED
& cross-members), refer to
Ext. Finishes Schedule for paint colour RENOVATION
Location
25 ARKANA DR
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
NORTH ELEVATIONS
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
PROPOSED NORTH ELEVATION 1:100 WD.502 C2
Page 11
site boundary
site boundary
existing fabric awning
to be removed
suite 2
46 mary street
existing awning columns (2no.),
noosaville qld 4566
beams & cross-members
to be removed po box 613
noosa heads qld 4567
existing balustrade
to Upper Level Terrace telephone 07 54473255
to be removed
facsimile 07 54473299
inf [email protected]
www.ct-design.com.au
building designer licence 1016347
This drawing is to be read in
conjunction with Engineers Drawings
& Reports.
Construction to comply with all
relevant SAA & BCA Codes &
standard Bldg By-law 1975 & as
amended.
Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
CONSULTANTS
EXISTING WEST ELEVATION 1:100 .
Structural Engineer
.
SCG Consulting Engineers
Contact: Matt 07 5455 5604
[email protected]
site boundary
site boundary
.
Surveyor
new RHS fascia beam, relocated
new RHS steel awning
columns (4no.), RHS beams & .
structurecross
awning members,
& column (below), Hass Survey
refer to Engineering & Contact: Phil Hass 0421 039 204
External Finishes Schedule refer to Proposed Roof Plan
& Engineers Design [email protected] awning to top of awning structure, Building Certifier
.
as specified Suncoast Building Approvals
Contact: 07 5443 7288
new zip screen cassette & guide rail, new zip screen cassette & guide rail, [email protected]
refer to Proposed South Elevation refer to Proposed South Elevation
new zip track drop down sunscreens dropdown dropdown dropdown
sunscreen sunscreen sunscreen
to perimeter of awning structure (5no.), new RHS awning columns (4no.),
refer to Series 700 Detail refer to engineers design
C2 Issued for Construction
new frameless glass balustrade, new frameless glass balustrade,
Revised 05.05.2021
refer to Series 700 Detail refer to Series 700 Detail
for Lodgement of Variation
Project
PROPOSED
NOTE: paint finish to new RENOVATION
steel awning structure, Location
(including columns, beams
& cross-members), refer to 25 ARKANA DR
Ext. Finishes Schedule for paint colour NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
WEST ELEVATIONS
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
PROPOSED WEST ELEVATION 1:100 WD.503 C2
Page 12
site boundary
site boundary
existing awning beams
& cross-members
to be removed
suite 2
46 mary street
noosaville qld 4566
existing awning columns (4no.)
to be removed po box 613
noosa heads qld 4567
existing balustrade to
Upper Level Terrace telephone 07 54473255
to be removed facsimile 07 54473299
inf [email protected]
www.ct-design.com.au
building designer licence 1016347
This drawing is to be read in
conjunction with Engineers Drawings
& Reports.
Construction to comply with all
relevant SAA & BCA Codes &
standard Bldg By-law 1975 & as
amended.
Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
CONSULTANTS
.
EXISTING SOUTH ELEVATION 1:100 Structural Engineer
.
SCG Consulting Engineers
Contact: Matt 07 5455 5604
[email protected]
site boundary
site boundary
new metal flashing/gable infill, paint finish, .
refer to External Finishes Schedule Surveyor
.
new RHS beam, in line with beam over, Hass Survey
refer to Engineers Design Contact: Phil Hass 0421 039 204
new awning to top of [email protected]
awning structure, .
refer to Proposed Roof Plan Building Certifier
.
Suncoast Building Approvals
new RHS fascia beam,
Contact: 07 5443 7288
refer to Engineering [email protected]
& Ext. Finishes Schedule
new zip track drop down sunscreens
to perimeter of awning structure (5no.), dropdown
zip screen
refer to Series 700 Detail
new awning columns (4no.) & beams, C2 Issued for Construction
refer to Engineers Design Revised 05.05.2021
for Lodgement of Variation
Project
new frameless glass balustrade,
refer to Series 700 Detail PROPOSED
RENOVATION
NOTE: paint finish to new Location
steel awning structure,
(including columns, beams 25 ARKANA DR
& cross-members), refer to NOOSA HEADS Q
Ext. Finishes Schedule for paint colour
Client
F & R SANDERS
Drawing Title
SOUTH ELEVATIONS
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
PROPOSED SOUTH ELEVATION 1:100 WD.504 C2
Page 13
site boundary
suite 2
46 mary street
noosaville qld 4566
po box 613
noosa heads qld 4567
new RHS beam, in line with column, & fixed to underside of rafter, telephone 07 54473255
refer to Engineering & External Finishes Schedule
facsimile 07 54473299
new awning beam within roof diaphragm
refer to Engineering inf [email protected]
new awning to top of
new awning structure, www.ct-design.com.au
refer to Proposed Roof Plan
building designer licence 1016347
proposed RHS fascia (50x150), ∘
Fall 2
finish as spec This drawing is to be read in
proposed AWNING ROOF PITCHING HT. conjunction with Engineers Drawings
& Reports.
new zip track drop down sunscreens
to perimeter of awning structure (5no.), dropdown
Construction to comply with all
refer to Series 700 Detail ht relevant SAA & BCA Codes &
hei g
sunscreen
2,475
max standard Bldg By-law 1975 & as
new frameless glass balustrade, 8 .0 m UPPER LEVEL amended.
refer to Series 700 Detail TERRACE Verify all dimensions on site prior to
existing TERRACE LEVEL
commencement of any works. These
drawings are not to be used for
NOTE: paint finish to new scaling. Copyright for design &
site boundary
steel awning structure, drawings remain the property of
(including columns, beams the authors.
& cross-members), refer to existing
existing
Ext. Finishes Schedule ENTRY COURT CONSULTANTS
for paint colour RESIDENCE .
Structural Engineer
.
SCG Consulting Engineers
Contact: Matt 07 5455 5604
N GL [email protected] Survey
existing Contact: Phil Hass 0421 039 204
POOL DECK [email protected] Certifier
.
Suncoast Building Approvals
Contact: 07 5443 7288
[email protected]
N GL C2 Issued for Construction
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
RENOVATION
SECTION A 1:100 Location
25 ARKANA DR
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
SECTION A
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
WD.601 C2
Page 14
varies - 125mm max
round top rail
fixed to external wall in a/w varies
manufacturers written instruction 125mm max
Top of Balustrade Top of Balustrade
38mm dia round suite 2
38mm dia round top rail 46 mary street
top rail, 316 polished line of zip drop down
316 polished s/steel as spec noosaville qld 4566
s/steel as spec screen guide
(in foreground) po box 613
noosa heads qld 4567
telephone 07 54473255
facsimile 07 54473299
1000mm MINIMUM ABOVE FFL
1000mm MINIMUM ABOVE FFL
inf [email protected]
12mm thick toughened 12mm thick toughened
12mm thick toughened safety glass
safety glass with polished safety glass with www.ct-design.com.au
with polished edges,
edges, sealed into polished edges, sealed
sealed into mini post gasket
mini post gasket into s/steel channel building designer licence 1016347
This drawing is to be read in
conjunction with Engineers Drawings
& Reports.
NOTE! mini post/spigot NOTE! mini post/spigot RHS awning column,
to be non-climbable to be non-climbable paint finish as spec Construction to comply with all
relevant SAA & BCA Codes &
2205 s/steel mini post/spigot 2205 s/steel mini post/spigot standard Bldg By-law 1975 & as
fixed into concrete slab in a/w fixed into concrete slab in a/w amended.
manufacturers written instruction manufacturers written instruction Verify all dimensions on site prior to
commencement of any works. These
2205 s/steel spigot 2205 s/steel spigot drawings are not to be used for
cover plate, as spec cover plate, as spec scaling. Copyright for design &
drawings remain the property of
stone tile on mortar bed, the authors.
stone tile on mortar bed,
refer to External
refer to External Finishes Schedule
Finishes Schedule Finished Floor Level CONSULTANTS
Finished Floor Level .
Structural Engineer
.
SCG Consulting Engineers
Contact: Matt 07 5455 5604
[email protected]! Framess Glass Balustrade Surveyor
.
to comply with BCA Vol.2 Part 3.9.2, Hass Survey
AS1288, AS1170.1 & AS2208 Contact: Phil Hass 0421 039 204
SECTION ELEVATION [email protected] Certifier
.
Suncoast Building Approvals
Contact: 07 5443 7288
[email protected]
FRAMELESS GLASS BALUSTRADE DETAIL - UPPER LEVEL TERRACE 1:10
C2 Issued for Construction
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
RENOVATION
Location
25 ARKANA DR
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
BALUSTRADE
DETAILS
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
WD.701 C2
The text continues on page 15.
Used in these records
Amended Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.