Council archive · source document
Amended Plans · 172007.545.02
Plans and drawings: the text below has words only, no drawings.
awning fixed to fascia beam
in a/w Manufacturers Written Instruction
proposed awning
to top of awning structure, as spec S1
cassette & zip guide dotted line indicates proposed cassette
proposed RHS fascia (50x150), (zip screen), fixed to inside edge of RHS beam
to north end of terrace finish as spec in a/w Manufacturers Written Instruction
suite 2
cassette & zip guide to south end of terrace 46 mary street
150
noosaville qld 4566
steel columns, paint finish as spec
50 po box 613
52 52 proposed zip screen guide noosa heads qld 4567
1,480
on site
side fixed into steel column
2480 tbc on site
in a/w Manufacturers Written Instruction telephone 07 54473255
zip screen
proposed zip screen facsimile 07 54473299
(falling to outer side of balustrade)
inf [email protected]
proposed frameless balustrade
balustrade
www.ct-design.com.au
1,000
as spec
building designer licence 1016347
This drawing is to be read in
conjunction with Engineers Drawings
& Reports.
Construction to comply with all
50 50 50 relevant SAA & BCA Codes &
50 100 1,750 100 100 1,500 100 1,500 100 100 1,500 100 1,500 100 100 1,500 100 1,500 100 710 50
glazed panel glazed panel glazed panel glazed panel glazed panel glazed panel glazed panel glazed, standard Bldg By-law 1975 & as
50 1,950 50 3,300 50 3,300 50 4,060 corner panel amended.
column column column column
Verify all dimensions on site prior to
commencement of any works. These
S1 drawings are not to be used for
scaling. Copyright for design &
BALUSTRADE SETOUT DETAIL - WEST ELEVATION 1:50 drawings remain the property of
the authors.
CONSULTANTS
.
Structural Engineer
.
SCG Consulting Engineers
Contact: Matt 07 5455 5604
[email protected]
proposed RHS beam (50x150mm) .
proposed RHS beam (50x150mm) cut (tapered) & fixed to underside Surveyor
.
cut (tapered) & fixed to underside of existing awning rafter Hass Survey
proposed steel beam/awning structure, refer to Engineering existing awning structure
of awning rafter to form gable end to form gable end Contact: Phil Hass 0421 039 204
proposed cassette for zip dropdown screen, proposed cassette for zip dropdown screen, [email protected]
fixed to RHS beam (beyond/in line with column), awning to top of structure, awning to top of fixed to RHS beam (beyond/in line with column) .
Building Certifier
in a/w Manufactureres Written Instruction as spec structure, as spec in a/w Manufactureres Written Instruction .
new welded connection new welded connection Suncoast Building Approvals
to engineers design to engineers design Contact: 07 5443 7288
[email protected]
150
150
150
proposed RHS fascia (50x150), metal flashing gable infill proposed RHS fascia (50x150),
finish as spec as spec finish as spec
proposed column/awning metal flashing gable infill proposed column/awning
proposed zip screen guide,
refer to External Finishes Schedule
on site
structure, paint finish as spec fixed into ex.wall structure, paint finish as spec
on site
tbc
tbc
proposed zip screen guide proposed zip screen guide, proposed zip screen guide C2 Issued for Construction
2,480 tbc on site
fixed into coloumn side fixed into ex.wall side fixed into coloumn Revised 05.05.2021
for Lodgement of Variation
proposed zip screen proposed zip screen
- to finished floor level - to finished floor level Project
proposed proposed
PROPOSED
RENOVATION
above FFL
above FFL
frameless balustrade, frameless balustrade,
1,000
1,000
refer to Balustrade Detail refer to Balustrade Detail Location
25 ARKANA DR
ex. terrace slab ex. terrace slab NOOSA HEADS Q
Client
F & R SANDERS
52 52 Drawing Title
98 48 1,300 75 1,300 75 1,300 75 1,200 45 52 52 45 1,200 75 1,300 75 1,300 75 1,300 48 98
BALUSTRADE
150 5,470 5,470 150 DETAILS
Scale Date
as shown @A3 2020
Drawn By Job No:
BALUSTRADE SETOUT DETAIL - SOUTH ELEVATION 1:50 BALUSTRADE SETOUT DETAIL - NORTH ELEVATION 1:50 SC 2010
Drawing No. Issue No.
WD.702 C2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Amended Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.