Council archive · source document
Amended Plans · 172007.545.02
Plans and drawings: the text below has words only, no drawings.
varies - 125mm max
round top rail
fixed to external wall in a/w varies
manufacturers written instruction 125mm max
Top of Balustrade Top of Balustrade
38mm dia round suite 2
38mm dia round top rail 46 mary street
top rail, 316 polished line of zip drop down
316 polished s/steel as spec noosaville qld 4566
s/steel as spec screen guide
(in foreground) po box 613
noosa heads qld 4567
telephone 07 54473255
facsimile 07 54473299
1000mm MINIMUM ABOVE FFL
1000mm MINIMUM ABOVE FFL
inf [email protected]
12mm thick toughened 12mm thick toughened
12mm thick toughened safety glass
safety glass with polished safety glass with www.ct-design.com.au
with polished edges,
edges, sealed into polished edges, sealed
sealed into mini post gasket
mini post gasket into s/steel channel building designer licence 1016347
This drawing is to be read in
conjunction with Engineers Drawings
& Reports.
NOTE! mini post/spigot NOTE! mini post/spigot RHS awning column,
to be non-climbable to be non-climbable paint finish as spec Construction to comply with all
relevant SAA & BCA Codes &
2205 s/steel mini post/spigot 2205 s/steel mini post/spigot standard Bldg By-law 1975 & as
fixed into concrete slab in a/w fixed into concrete slab in a/w amended.
manufacturers written instruction manufacturers written instruction Verify all dimensions on site prior to
commencement of any works. These
2205 s/steel spigot 2205 s/steel spigot drawings are not to be used for
cover plate, as spec cover plate, as spec scaling. Copyright for design &
drawings remain the property of
stone tile on mortar bed, the authors.
stone tile on mortar bed,
refer to External
refer to External Finishes Schedule
Finishes Schedule Finished Floor Level CONSULTANTS
Finished Floor Level .
Structural Engineer
.
SCG Consulting Engineers
Contact: Matt 07 5455 5604
[email protected]! Framess Glass Balustrade Surveyor
.
to comply with BCA Vol.2 Part 3.9.2, Hass Survey
AS1288, AS1170.1 & AS2208 Contact: Phil Hass 0421 039 204
SECTION ELEVATION [email protected] Certifier
.
Suncoast Building Approvals
Contact: 07 5443 7288
[email protected]
FRAMELESS GLASS BALUSTRADE DETAIL - UPPER LEVEL TERRACE 1:10
C2 Issued for Construction
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
RENOVATION
Location
25 ARKANA DR
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
BALUSTRADE
DETAILS
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
WD.701 C2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.