proposed awning fixed to RHS fascia proposed awning fixed to RHS fascia
in a/w Manufacturers Written Instruction in a/w Manufacturers Written Instruction
proposed RHS fascia
150
proposed RHS fascia (50x150),
(50x150) capped,
finish as spec
finish as spec
proposed zip screen cassette, proposed zip screen cassette,
as spec as spec
suite 2
46 mary street
noosaville qld 4566
proposed terrace awning proposed terrace awning
to top of steel awning structure, to top of steel awning structure, po box 613
as spec as spec noosa heads qld 4567
line of proposed RHS beam
(50x150) behind cassette, telephone 07 54473255
cut (tapered) & fixed to underside
of ex. awning rafter facsimile 07 54473299
108 42 52 98 inf [email protected]
150 150 www.ct-design.com.au
building designer licence 1016347
This drawing is to be read in
conjunction with Engineers Drawings
& Reports.
Construction to comply with all
relevant SAA & BCA Codes &
standard Bldg By-law 1975 & as
amended.
proposed zip screen guide, proposed zip screen guide,
as spec as spec Verify all dimensions on site prior to
commencement of any works. These
drawings are not to be used for
scaling. Copyright for design &
drawings remain the property of
the authors.
2480 - to be confirmed on site
2480 - to be confirmed on site
CONSULTANTS
proposed/ex. steel awning column, proposed/ex. steel awning column, .
paint finish, as spec paint finish, as spec Structural Engineer
.
SCG Consulting Engineers
Contact: Matt 07 5455 5604
[email protected] Survey
proposed dia round top rail Contact: Phil Hass 0421 039 204
as spec [email protected] Certifier
.
Suncoast Building Approvals
Contact: 07 5443 7288
[email protected]
C2 Issued for Construction
proposed frameless glass balustrade panel proposed frameless glass balustrade Revised 05.05.2021
as spec shown hidden for clarity for Lodgement of Variation
min 1000mm
Project
PROPOSED
RENOVATION
Location
25 ARKANA DR
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
TYPICAL COLUMN
proposed s/steel mini post, DETAIL
as spec Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
SECTION S1 - TYPICAL COLUMN DETAIL 1:10 ELEVATION - NORTHERN END COLUMN 1:10 Drawing No. Issue No.
WD.703 C2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Amended Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.