Plans and drawings: the text below has words only, no drawings.
13,050 1,700
240 3,720 90 3,650 90 5,020 240 1,700
240 3,720 90 3,650 90 1,055 2,620 1,345 1,700
240 1,700 70 1,950 90 1,860 90 1,700 90 3,010 90 2,070 90 1,610 90
suite 2
90 650 390 46 mary street
noosaville qld 4566
po box 613
noosa heads qld 4567
370
290
telephone 07 54473255
facsimile 07 54473299
existing
1,850
1,770
GROUND FLOOR PATIO inf [email protected]
1,480
1,480
new carpet to Bedroom & WIR,
tile
240
UP
'By Client' www.ct-design.com.au
building designer licence 1016347
240
240
240
240
240
Waterproofing in accordance
1,400
new floor tiles with AS3740 required to This drawing is to be read in
to match existing laundry and ensuite conjunction with Engineers Drawings
& Reports.
3,050
existing d proposed
90
4,300
3,870
CD
BED 2 proposed Construction to comply with all
4,060
wm
BED 1 new wall infill to match existing,
4,470
L'DRY relevant SAA & BCA Codes &
t new carpet paint finish as spec standard Bldg By-law 1975 & as
2,325
D01
120
new laundry plumbing king size
new hinged door, amended.
& joinery, as specified refer to Door Schedule
new nib walls (2no.), Verify all dimensions on site prior to
new floor tiles,
890
linen
70 70
to match existing commencement of any works. These
90
as specified drawings are not to be used for
90
530
robe new nib wall to shower, scaling. Copyright for design &
90
tiled as specified drawings remain the property of
1,390
existing
9,820
70
1,000
ex.WC 8 proposed the authors.
WIR b shower new glass shower screen/door,
U
2,460
7
P
new carpet ENSUITE as specified
6
CONSULTANTS
11,950
70
5 7 new tile
new shower rose & mixer,
70
.
1,000
4 8
b ex.W C wc Structural Engineer
9 as specified
3,880
3
13,650
existing 10 t/r .
2,140
2 new vanity with double basin SCG Consulting Engineers
5,915
BATH 1 11
& mixers, refer to Series 800 Contact: Matt 07 5455 5604
90
90
12
Joinery Drawings [email protected]
UP 13 .
70 600 70
Surveyor
.
robe existing Hass Survey
ENTRY Contact: Phil Hass 0421 039 204
9,350
[email protected]
70
1 .
2 Building Certifier
.
3 Suncoast Building Approvals
existing UP 4 existing Contact: 07 5443 7288
2,980
2,980
6,620
6,620
BED 3 GARAGE [email protected]
1,800 90
1,800 90
ex.concrete
C2 Issued for Construction
240
240
Revised 05.05.2021
for Lodgement of Variation
Project
PROPOSED
90
90
RENOVATION
Location
25 ARKANA DR
240 2,650 70 1,000 90 2,660 90 900 90 3,010 90 2,070 90 1,610 90
NOOSA HEADS Q
Client
240 2,650 70 1,000 90 3,330 90 7,190 90
F & R SANDERS
240 3,720 240 3,180 90 7,190 90 Drawing Title
4,200 3,180 7,370 PROP. GROUND
N
14,750 FLOOR PLAN
Scale Date
as shown @A3 2020
Drawn By Job No:
SC 2010
Drawing No. Issue No.
PROPOSED GROUND FLOOR PLAN 1:100
WD.205 C2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Amended Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.