Council archive · source document
Amended Plans · 172007.545.02
Plans and drawings: the text below has words only, no drawings.
line of proposed RHS fascia beam
over, refer to Engineering
line of proposed zip screen
cassette over, as spec proposed zip screen guide
Balcony waterproofing to
comply with AS4654.
Minimum 70mm vertical proposed frameless balustrade
as spec
upturn of membrane required ex.awning structural column suite 2
for an N3 wind classification 46 mary street
proposed zip screen guide noosaville qld 4566
13,050 line of proposed zip screen cassette po box 613
over, as spec
noosa heads qld 4567
line of proposed RHS beam
4,250 8,750 50 over, refer to Engineering telephone 07 54473255
Glass balustrades to new awning over
have interlinking proposed frameless balustrade facsimile 07 54473299
handrail or top rail 4,250 50 3,300 50 3,300 50 1,950 50 as spec
inf [email protected]
new column new column
ex. column ex. column
www.ct-design.com.au
new RHS awning columns (4no.) building designer licence 1016347
refer to Engineers design
This drawing is to be read in
190
190
awning columns
awning columns
refer to detail inset (above)
new frameless glass balustrade, conjunction with Engineers Drawings
& Reports.
new
new
refer to External Finishes Schedule
150
150
and WD.701/702 Balustrade Detail new zip track drop down sunscreens Construction to comply with all
to perimeter of awning structure (5no.), relevant SAA & BCA Codes &
new tiles to existing terrace slab, as specified standard Bldg By-law 1975 & as
refer to External Finishes Schedule
proposed amended.
new tiles to existing terrace slab,
UPPER LEVEL TERRACE
e
new awning over,
ng
refer to External Finishes Schedule Verify all dimensions on site prior to
5,810
ou
refer to Proposed Roof Plan new tiles commencement of any works. These
nl
new frameless glass balustrade,
5,810
su
drawings are not to be used for
5,470
5,470
new awning beams (over), lounge refer to External Finishes Schedule
rug scaling. Copyright for design &
e
refer to Engineers Design and WD.701/702 Balustrade Detail
ng
dining drawings remain the property of
ou
& Proposed Roof Plan lounge
the authors.
nl
new tiles new tiles
su
fall 1:100 fall 1:100
new zip track drop down sunscreens
to perimeter of awning structure (5no.), CONSULTANTS
as specified .
planters
Structural Engineer
step step provide water connection .
down down for future outdoor sink SCG Consulting Engineers
Contact: Matt 07 5455 5604
new awning beam [email protected]
90
90
90
15
14
13
(within roof diaphragm), .
12
11
UP Surveyor
10
refer to Engineers design
9
.
8
7 Hass Survey
2,620
6 existing
Contact: Phil Hass 0421 039 204
2,990
chair chair
DINING [email protected]
new finish to ex.timber .
Building Certifier
new finish to .
existing 1
existing timber floorboards Suncoast Building Approvals
2
LIVING 'By Client' Contact: 07 5443 7288
120
3
6,370
new carpet [email protected]
new carpet to Living 4
'By Client' UP
7,820
7,820
sofa
new finish to C2 Issued for Construction
tv
4,900
existing timber floorboards
4,650
existing Revised 05.05.2021
sofa 'By Client'
LIGHT for Lodgement of Variation
WELL Project
keyboard
70
(over) existing
PROPOSED
piano/
KITCHEN
ex. RENOVATION
1,200
new finish to ex.timber
WC ex.PDR
ex.tile Location
25 ARKANA DR
90
90
90
NOOSA HEADS Q
Client
F & R SANDERS
Drawing Title
PROPOSED UPPER
N
LEVEL FLOOR PLAN
Scale Date
230 1,860 70 920 70 3,920 70 5,820 90 as shown @A3 2020
13,050 Drawn By Job No:
SC 2010
Drawing No. Issue No.
PROPOSED UPPER LEVEL FLOOR PLAN 1:100
WD.206 C2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Amended Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.