Original source · versioned page text
2020-10-12 GC Agenda - Item 6 - Attachment 1 - Proposal
Very large file: it may take a few minutes
The original of this document is very large (21.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
REV DESCRIPTION DRN DATE
A MCU DA Issue MS 25.02.20
B MCU DA Issue MS 02.03.20
HWS / HYD
C MCU DA Issue MS 06.03.20
Gas D Client Revisions MS 14.04.20
E MCU DA MS 05.08.20
Store / Information Response
Lockers
(no works)
Back-of-house
(no works)
Store
HYD
100 x 25 RHS
powdercoated
aluminium batten
FHR
screen spanning from
top of existing upstand
wall to underside of
new roof over Existing Cafe Existing blade columns to
New anodised New anodised aluminium- New feature signage panels Feature timber seat on
(no works) extend to underside of
aluminium-framed framed full-height glass suspended between blade recessed concrete base,
Refuse new awning over. Select
shopfront glazing corner window walls to future detail downlighting under
render and paint finish
Fire Hose Reel to be
relocated to suit
egress requirements
Generally throughout:
Path of egrees to be
painted out to ensure - New render and paint finish to all external walls
1.0 m clear width
COL - New anodised aluminium (25µm coating)
sliding doors to terraces / balconies
DP HYD - New anodised aluminium (25µm coating) windows
Gate
- New frameless glass balustrade with
anodised aluminium (25µm coating) uprights
- New tiles to walkways, terraces and balconies
Existing blade
columns to extend to
underside of new
awning over. Select
render and paint finish COL
Tenancy Tenancy
New anodised
aluminium-framed
shopfront glazing
Suite 2,
Cnr Gard
New anodised
Alexand
aluminium-framed PO Box
glass bi-fold
shopfront doors P 07 54
100 x 25 RHS powdercoated admin@
New awning cantilevered off New anodised
aluminium batten screen spanning
existing wall and supported aluminium-framed glass
New anodised from top of existing upstand wall
by blade wall extensions bi-fold shopfront doors
aluminium-framed to underside of new roof over
full-height glass SUNCOAST RESORT BUSINESS CENTRE
corner window SUITE 2 CNR GARDAK ST & SURF RD
ALEXANDRA HEADLAND Qld 4572
2500 PO BOX 6232 MAROOCHYDORE BC Qld 4558
PH : 07 5443 5028 FAX:07 5479 2380
ABN 23 123 917 724
EMAIL: [email protected]
DP
project
New anodised
aluminium-framed glass
New anodised aluminium- Line of new awning PROPOSED ALTERATIONS &
2325
framed shopfront glazing over shown dotted COL
bi-fold shopfront doors ADDITIONS TO EXISTING
Existing trees to RESORT BUILDING
Line of new awning New blockwork wall with be retained.
FWG New steel stud wall to for
over shown dotted select render and paint finish
future detail. Extend to
underside of roof over
NETANYA RESORT
at
Timber seating to back
8580
Step wall of raised terrace 75 HASTINGS STREET
LED strip light
under seat as
x2 NOOSA HEADS
per future detail
drawing
New tree
DETAILED AREA - SOUTH-
3730
WEST TENANCIES / REFUSE
3455
Seat Seat
Existing floor waste New
grate to be retained landsc. 300 3500 290 AREA
planter
FWG
AS SHOWN
date 5/08/2020 drawn JP scale @A1
COL
drawing no. 19021 SD60.00 revision E
Select feature timber Feature timber seat on New blockwork planter Select feature timber
New deep landscaping Feature timber seat on Select feature timber Existing trees to be retained.
decking over existing recessed concrete base, wall with stone-clad finish decking over existing LED strip lighting under
planter in ground recessed concrete base, decking over existing Provide new additional landscaping
concrete slab / footpath downlighting under to match existing concrete slab / footpath seat as per future detail Copyright of this document remains the exclusive
downlighting under concrete slab / footpath as per landscape architect's details
N
property of SPROUT ARCHITECTS PTY LTD
ABN 23 123 917 724.
Storm Water
Connection
GROUND LEVEL Contractors are to verify all dimensions and levels on
site prior to commencing. Report all discrepancies to
the Architect. Use figured dimensions in preference
Scale 1:50 0 5 10 to scaled.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.