Original source · versioned page text
REFERENCE DOCUMENTS - RAL25/0004 (As Published)
Very large file (40.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 42, section 1. The text section number identifies this passage in the reader.
• Collection of grab soil samples from either the side of the test pit or from the bucket of the excavator
using gloved hands, or sampling trowel with respect to other surface samples. Nitrile gloves were
changed for each sample collected
• Most sample locations included collection of soil samples at the surface or 0.25 mbgl, 0.5 mbgl, 1
mbgl then every 0.5 mbgl or as required by the SAQP or the judgement of the SQP based on field
observations
• Based on field observations, sampling continued into natural soils below the base of all encountered
wastes
• Collection of field duplicate samples with an analysis target of 1 field duplicate per 10 primary field
samples analysed in accordance with primary samples. With reference to Table 11 the actual field
duplicate to primary ratios were as follows:
- 1:11.7 Metals
- 1:11.6 OCP/OPP
- 1:11 SVOC
- 1:11 TRH/BTEXN
- 1:10 PFAS
- 1:10 PAH
- 1:10 PCB
- no asbestos duplicates were collected.
• Collection and analysis of field triplicates with an analysis target of 1 field triplicate per 20 primary
field samples analysed, with analysis of the primary and duplicate sample at the primary laboratory,
and analysis of the triplicate at a second NATA accredited laboratory. With reference to Table 11 the
actual field triplicate to primary ratios were as follows:
- 1:22 Metals
- 1:22 TRH/BTEXN
- 1:20 PFAS
- 1:17.5 OCP/OPP
- 1:15 PAH
- 1:15 PCB
- no asbestos or SVOC triplicates were collected.
• Use of laboratory supplied blank samples (analysed in accordance with primary samples) that was
used from the commencement of PSI, DSI 1 and DS12 soil sampling activities and analysed for
volatile TRH and, for DSI 1, PFAS
• Use of properly calibrated PID and LFG monitors with calibration certificates presented in Appendix O
• Samples were collected in laboratory prepared jars and placed in chilled insulated containers for
transport to the laboratory
• Logging of location, lithology, sample depths, observations and signs of potential contamination,
water ingress etc
125 Lot 105 SP118458 Cooroy DSI 12062024 Rev0 Lot 105 SP118458, Cooroy, QLD, 4563
12/06/2024 38 Detailed Site Contamination Investigation