6.5. VAPOUR AND LANDFILL GAS SAMPLING
The disposal of night soil over the AEC 1 northern portion of the site is associated with the likely historical
generation of landfill gas (LFG or biogas). There was no historical or field evidence of landfilled
putrescible materials over the AEC 2 southern portion of the site.
Whilst decomposition over the subsequent approximately 50 years since deposition is expected to have
limited present-day LFG generation, confirmatory evidence was required in accordance with:
• NSW EPA Contaminated Land Guidelines - Assessment and management of hazardous ground
gases, 2020 (NSW EPA 2020)
• DES (now DESI), 2017, Model operating conditions, ERA 60 – Waste disposal. Brisbane: Department
of Environment and Science Government (ERA 60)
As with general land contamination assessment, and as noted by Section 3 of NSW EPA 2020, a staged
approach was undertaken to maximise the effectiveness of the LFG site assessment work and minimise
its costs, with opportunistic surface monitoring undertaken during DSI 1 and a formal sub-surface
assessment during DSI 2.
6.5.1. DSI 1 LFG WORKS
The technique of surface emission measurement may be applied to bulk gases of typically closed landfills
or other filled ground (NSW EPA 2020, Appendix A4.1, Table 18). Opportunistic surface monitoring during
DSI 1 was used to provide an additional line of evidence to confirm the CSM and support future LFG
borehole placement, with all test pits screened, including those over AEC 2 where an LFG source was not
expected.
With an absence of major service trenches or similar underground infrastructure, the surface screening
focused on the excavated test pits, any adjacent cracked soil voids, site boundary adjacent housing and
the recently constructed shed.
With reference to Section 3.4.4 and Appendix A4.5.2 of NSW EPA 2020 and Section 5.2 of NSW EPA
Environmental Guidelines, Solid waste landfills, 2nd edition, 2016 (NSW EPA 2016) the DSI 1 surface
monitoring methodology included:
• Using a calibrated “Eagle 2” landfill gas monitor with a methane senor detection level of at least
20ppm, with the monitor able to further record at explosivity (PID surrogate), carbon dioxide and
oxygen (refer to Appendix O for calibration certificate)
• Testing undertaken preferably during low wind conditions (<10km/h) and relatively low and stable
atmospheric pressure (less than 101.3 kPa)
• The LFG monitoring occurred as follows in accordance with the SAQP:
- in the atmosphere no greater than 5cm above the ground surface or otherwise within the
excavated test pit at various recorded depths within 5cm of the test pit base or wall
- continuous transects at the site boundary immediately bordering residential housing located east
and west of the site.
- within and around the shed at various ground and ceiling locations.
125 Lot 105 SP118458 Cooroy DSI 12062024 Rev0 Lot 105 SP118458, Cooroy, QLD, 4563
12/06/2024 49 Detailed Site Contamination Investigation
Document Set ID: 23717062
Version: 0, Version Date: 01/01/1900
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.