SEACHANGE BUILDERS
All designs, plans and drawings including all associated materials are subject
to copyright. Either written, design or specification is vested in
SEACHANGE BUILDERS design center.
Any attempt or actural infringement by using, reproducing or copying the same,
wholly or in part without written consent will result in legal action being taken.
BUILDER N O T E :
1. DO NOT SCALE DRAWINGS, USE WRITTEN DIMENSIONS ONLY.
Demolition Note 2. OWNER, BUILDER, SUBCONTRACTOR MUST VERIFY ALL DIMENSIONS
AND LEVELS ON SITE PRIOR TO COMMENCING ANY WORKS OR
ORDERING MATERIALS.
· REMOVAL OF HAZARDOUS BUILDING REMOVE EXISTING WALL 3. BUILDER SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING
WORKS CONFORM TO THE BUILDING CODE OF AUSTRALIA, A.S CODES
FOR PROPOSED MASTER SUITE (CURRENT EDITIONS) BUILDING REGULATIONS, LOCAL BY-LAWS AND
MATERIALS SHALL OCCUR PRIOR TO REFER TO PROPOSED FLOOR PLAN TOWN PLANNING REQUIREMENTS REPORT. ALL DISCREPANCIES TO BE
REFERRED TO OWNERS OFFICE FOR CLARIFICATION.
COMMENCEMENT OF WORKS.
4. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ARCHITECTURAL
CONTRACTOR SHALL INFORM REMOVE EXISTING ROBE AND JOINERY SPECIFICATION AND ENGINEERS SHOP DRAWINGS AND DETAILS.
ARCHITECT IMMEDIATELY IF ANY RETAIN ELEMENTS AS PER 5. REGULAR INSPECTION OF THE PROPERTY BY A SUITABLY QUALIFIED
HAZARDOUS BUILDING MATERIALS PROPOSED FLOOR PLAN
PERSON AND THE ARRANGEMENT, SCHEDULING AND PAYMENT OF THE
INSPECTIONS WILL BE THE SOLE RESPONSIBILITY OF THE OWNER OR
ARE FOUND DURING BUILDER.
CONSTRUCTION. REMOVE EXISTING ENSUITE AND JOINERY
REFER TO PROPOSED NEW OPENING
CONTRACT N O T E :
· PLANS & RCP's REPRESENT AREAS 1. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL
AS ALREADY HAVING HAZARDOUS REMOVE EAVES OVER LOWER FLOOR CURRENT ENGINEERING DOCUMENTATION AND SPECIFICATIONS.
MATERIALS REMOVED. REFER TO PROPOSED FLOOR PLAN 2. BUILDERS SPECIFICATION AND NOMINATED FEES TAKE PRECEDENTS
OVER DRAWING NOTES.
3. SIZES OF ITEMS INCLUDING WASHING MACHINE, DRYER, MICRO WAVE
· ALL SERVICES TO REMAIN SHALL BE AND OVEN OR THE LIKE ARE TO BE CONFIRMED IN THE WRITTEN
DOCUMENTATION PREPARED BY THE BUILDER.
CHECKED & REDUNDANT SERVICES
REMOVED. -------------------------------- -------------------------
OWNER BUILDER
· ALL AFFECTED SURFACES BY
-------------------------------- -------------------------
DEMOLITION WORKS TO BE MADE DATE DATE
GOOD.
· GENERALLY, EXISTING DEMOLISHED EXISTING AREAS
MATERIALS MAY BE RE-USED ONLY EXIST. BBQ & POOL LVL - 114.2m²
ON THE WRITTEN APPROVAL OF REMOVE EXISTING WALL TO MASTER EXIST. GROUND LVL - 323.8m²
THE ARCHITECT, UNLESS RE-USE IS BEDROOM EXIST.UPPER LVL - 283.6m²
SPECIALLY NOTED. CONFIRM WITH BUILDER ONSITE.
TOTAL AREA - 721.6m²
· BUILDER TO REMOVE ALL
DEMOLISHED MATERIAL FROM SITE.
REMOVE EXISTING BULKHEADS
OVER ENTRY AND BEDROOM 3.
PROPOSED AREAS
REFER TO PROPOSED ELEVATIONS PRO. BBQ & POOL LVL 114.2m²
PROPOSED. GROUND LVL - 323.8m²
PROPOSED.UPPER LVL - 283.6m²
TOTAL AREA - 721.6m²
· BUILDER TO ENSURE THAT
DEMOLITION CONTRACTOR REMOVE EXISTING WALL FOR
INSPECTS SITE BEFORE PROVIDING PROPOSED SLIDING DOOR ACCESS
A QUOTE. NO PRICE VARIATIONS
WILL BE ACCEPTED FROM UTILITY CONTACTS
REMOVE CORNER WINDOW
DEMOLITION CONTRACTOR FOR 1. WATER:
NOT HAVING PROPERLY INSPECTED REMOVE EXISTING WALLS TO
2.
SITE BEFORE QUOTING. LIVING AREA 3. GAS:
· BUILDER TO ENSURE THAT ALL
SUPPLY SERVICES (GAS, WATER & 4. TELEPHONE:
REMOVE EXISTING PLUMBING TELSTRA
ELECTRICITY) ARE TERMINATED AS AND FITTINGS AS PER REQUIRED 13 22 00
REQUIRED TO ENABLE SAFE EXISTING TOILET TO REMAIN
EXCAVATION OR CONSTRUCTION, 5. POWER:
AND TO BE REINSTATED AS PER
SERVICES ENGINEER'S REDIRECT EXISTING STAIRCASE
DOCUMENTATION. REFER TO PROPOSED FLOOR PLAN
N O T E:
CONFIRMED ALL DIMENSIONS ON SITE.
· BUILDER TO ENSURE THAT ALL REMOVE EXISTING ROBE AND WALLS ALL CONTRACTORS ARE TO PROVIDE COMPLIANCE
OF EXISTING BEDROOM CERTIFICATES FOR ELECTRICAL, PLUMBING AND
NECESSARY PROTECTION OF MECHANICAL ON COMPLETION.
REFER TO PROPOSED FLOOR PLAN
ADJOINING PROPERTIES IS TAKEN,
INCLUDING ALL BUILDING NORTH POINT
REMOVE WALLS AND JOINERY DETAILS
STRUCTURES AND PUBLIC ASSETS, OF THE STUDY AND KITCHENETTE LOCATION
AND MAKE GOOD WHERE DAMAGED Latitude: 26.4569° S,
OR DEGRADED BY DEMOLITION OR Longitude: 153.0991° E
CONSTRUCTION WORKS. MARCUS BEACH, QLD
· CONTRACTOR TO CHECK
THROUGHOUT THE BUILDING AND
ALLOW FOR REMOVAL/DEMOLITION 3 WINE CELLAR AND LIFT 16.1.22
OF ANY BROKEN WINDOW GLAZING. 2 CLIENT CHANGES 10.12.21
1 INITIAL CLIENT DRAFT 10.11.21
Demo.Upper.flr
DAYTONA AVE COOLUM BEACH
Sunshine Coast Qld 4562
Ph 07 3103 2996 Mob 0438231411
BSA License 121 2275
Scale: 1:100 Dwg No: SH-10
Date : FEB 2022 Job No: 2021-73.10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
3. 220148 - Architectural Plans - 51 Tristania.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.