3. 220148 - Architectural Plans - 51 Tristania · 132006.2554.01

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                                                                                                     SEACHANGE BUILDERS
                                                                                                        All designs, plans and drawings including all associated materials are subject
                                                                                                                to copyright. Either written, design or specification is vested in
                                                                                                                           SEACHANGE BUILDERS design center.
                                                                                                       Any attempt or actural infringement by using, reproducing or copying the same,
                                                                                                        wholly or in part without written consent will result in legal action being taken.




    Demolition Note                                                                                    BUILDER N O T E :
                                                                                                       1. DO NOT SCALE DRAWINGS, USE WRITTEN DIMENSIONS ONLY.

                                                                                                       2. OWNER, BUILDER, SUBCONTRACTOR MUST VERIFY ALL DIMENSIONS
·   REMOVAL OF HAZARDOUS BUILDING                                                                      AND LEVELS ON SITE PRIOR TO COMMENCING ANY WORKS OR
                                                                                                       ORDERING MATERIALS.
    MATERIALS SHALL OCCUR PRIOR TO
                                                                                                       3. BUILDER SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING
    COMMENCEMENT OF WORKS.                                                                             WORKS CONFORM TO THE BUILDING CODE OF AUSTRALIA, A.S CODES
                                                                                                       (CURRENT EDITIONS) BUILDING REGULATIONS, LOCAL BY-LAWS AND
    CONTRACTOR SHALL INFORM                                                                            TOWN PLANNING REQUIREMENTS REPORT. ALL DISCREPANCIES TO BE
                                                                                                       REFERRED TO OWNERS OFFICE FOR CLARIFICATION.
    ARCHITECT IMMEDIATELY IF ANY
                                                                                                       4. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ARCHITECTURAL
    HAZARDOUS BUILDING MATERIALS                                                                       SPECIFICATION AND ENGINEERS SHOP DRAWINGS AND DETAILS.

    ARE FOUND DURING                                                                                   5. REGULAR INSPECTION OF THE PROPERTY BY A SUITABLY QUALIFIED
                                                                                                       PERSON AND THE ARRANGEMENT, SCHEDULING AND PAYMENT OF THE
    CONSTRUCTION.                                                                                      INSPECTIONS WILL BE THE SOLE RESPONSIBILITY OF THE OWNER OR
                                                                                                       BUILDER.


·   PLANS & RCP's REPRESENT AREAS
    AS ALREADY HAVING HAZARDOUS                                                                         CONTRACT N O T E :
    MATERIALS REMOVED.                         REMOVE EXISTING WALL FOR                                 1. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL
                                                                                                        CURRENT ENGINEERING DOCUMENTATION AND SPECIFICATIONS.
                                                 PROPOSED NEW OPENING
·   ALL SERVICES TO REMAIN SHALL BE                                                                     2. BUILDERS SPECIFICATION AND NOMINATED FEES TAKE PRECEDENTS
                                                                                                        OVER DRAWING NOTES.
    CHECKED & REDUNDANT SERVICES                                                                        3. SIZES OF ITEMS INCLUDING WASHING MACHINE, DRYER, MICRO WAVE
    REMOVED.                                 REMOVE EXISTING FLOOR AND                                  AND OVEN OR THE LIKE ARE TO BE CONFIRMED IN THE WRITTEN
                                                                                                        DOCUMENTATION PREPARED BY THE BUILDER.
                                                   WALLS FOR NEW WORKS
·   ALL AFFECTED SURFACES BY                AS PER PROPOSED FLOOR PLAN                                 --------------------------------                  -------------------------
    DEMOLITION WORKS TO BE MADE                                                                               OWNER                                             BUILDER
    GOOD.                                                                                              --------------------------------                  -------------------------
                                                                                                              DATE                                              DATE
·   GENERALLY, EXISTING DEMOLISHED
    MATERIALS MAY BE RE-USED ONLY
    ON THE WRITTEN APPROVAL OF                                                                          EXISTING AREAS
    THE ARCHITECT, UNLESS RE-USE IS          REMOVE EXISTING DECKING AS                                 EXIST. BBQ & POOL LVL                            - 114.2m²
    SPECIALLY NOTED.                           PER PROPOSED FLOOR PLAN                                  EXIST. GROUND LVL                                - 323.8m²
                                                                                                        EXIST.UPPER LVL                                  - 283.6m²
·   BUILDER TO REMOVE ALL
                                         REMOVE EXISTING WALLS OF LIVING
                                            ROOM AS PER PROPOSED PLAN                                   TOTAL AREA                                       -    721.6m²
    DEMOLISHED MATERIAL FROM SITE.
                                                                                                        PROPOSED AREAS
                                                                                                        PRO. BBQ & POOL LVL    114.2m²
                                                                                                        PROPOSED. GROUND LVL - 323.8m²
                                                                                                        PROPOSED.UPPER LVL   - 283.6m²
·   BUILDER TO ENSURE THAT
    DEMOLITION CONTRACTOR                                                                               TOTAL AREA                                       -    721.6m²
    INSPECTS SITE BEFORE PROVIDING
    A QUOTE. NO PRICE VARIATIONS
    WILL BE ACCEPTED FROM
    DEMOLITION CONTRACTOR FOR
                                                                                                         UTILITY CONTACTS
    NOT HAVING PROPERLY INSPECTED          REMOVE EXISTING BALUSTRADING
    SITE BEFORE QUOTING.                  REFER TO PROPOSED FLOOR PLAN                                   1.         WATER:
                                                                                                         2.
·   BUILDER TO ENSURE THAT ALL                                                                           3.        GAS:
    SUPPLY SERVICES (GAS, WATER &
    ELECTRICITY) ARE TERMINATED AS    REMOVE EXISTING WALLS AND FOOTING
    REQUIRED TO ENABLE SAFE             SYSTEM WITH ACCESS TO LIFT AREA.                                 4.         TELEPHONE:
                                                                                                                    TELSTRA
    EXCAVATION OR CONSTRUCTION,                  REFER TO BUILDER ONSITE                                            13 22 00
    AND TO BE REINSTATED AS PER
                                                                                                         5.        POWER:
    SERVICES ENGINEER'S
    DOCUMENTATION.                          REMOVE EARTH WORKS FOR
                                PROPOSED NEW LIFT. REFER TO PROPOSED
·   BUILDER TO ENSURE THAT ALL            FLOOR PLAN AND LIFT DETAILS                                                         N O T E:
    NECESSARY PROTECTION OF                                                                                      CONFIRMED ALL DIMENSIONS ON SITE.
                                                                                                            ALL CONTRACTORS ARE TO PROVIDE COMPLIANCE
    ADJOINING PROPERTIES IS TAKEN,
                                                 REMOVE BLOCK WALL AND                                       CERTIFICATES FOR ELECTRICAL, PLUMBING AND
    INCLUDING ALL BUILDING                                                                                          MECHANICAL ON COMPLETION.
                                               EXISTING INFRASTRUCTURE.
    STRUCTURES AND PUBLIC ASSETS,
    AND MAKE GOOD WHERE DAMAGED           REFER TO PROPOSED FLOOR PLAN                                                                    NORTH POINT
    OR DEGRADED BY DEMOLITION OR                                                                                                          LOCATION
    CONSTRUCTION WORKS.                                                                                                                   Latitude: 26.4569° S,
                                         REMOVE EXISTING EAVE AT GARAGE
                                                                                                                                          Longitude: 153.0991° E
                                      FACADE. FINISH LEVEL WITH PROPOSED                                                                  MARCUS BEACH, QLD
·   CONTRACTOR TO CHECK                             NEW CARPORT CEILING.
    THROUGHOUT THE BUILDING AND
    ALLOW FOR REMOVAL/DEMOLITION
    OF ANY BROKEN WINDOW GLAZING.
                                                                                                        3         WINE CELLAR AND LIFT                                           16.1.22
                                                                                                        2         CLIENT CHANGES                                                 10.12.21
                                                                                                        1         INITIAL CLIENT DRAFT                                           10.11.21




                                                                           Demolition Sub-Floor Plan     Demolition Plan




                                                                                                            DAYTONA AVE COOLUM BEACH
                                                                                                            Sunshine Coast Qld 4562
                                                                                                            Ph 07 3103 2996 Mob 0438231411
                                                                                                            BSA License 121 2275

                                                                                                            Scale:             1:100                    Dwg No:                    SH-8

                                                                                                            Date : FEB 2022                              Job No: 2021-73.8

Used in these records

About this file

File size
9.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

3. 220148 - Architectural Plans - 51 Tristania.pdf · 9.0 MB (large file)