Council archive · source document
MCU21.0117 OPW21.0199-Att 5 Stormwater · MCU21/0117
Figure 4.4 – Typical Tank node configuration
Each tank is to be fitted with a first flush diverter to prevent potential sediments from
entering the tanks. This is modelled by assuming the first 25L of rainfall falling over the roof
area is diverted to the first flush diverter and discharged to irrigate vegetated areas on site,
equating to a 0.12mm increase to the rainfall threshold on the upstream roof source node.
The tanks will be plumbed for internal and external reuse which has been modelled in
accordance with the Water by Design MUSIC Modelling guidelines. The reuse demands
have been determined as follows:
- Internal Reuse
o All homes are assumed to be fitted with full water saving devices,
▪ 26L/Person/day for laundry
▪ 21L/Person/day for toilets
o ½ Pod C roof run-off:
▪ 2x2 bed = 3.2 persons
▪ 3.2 * 47L = 150.4L/day
Page 15 of 33
P +61 7 5211 1003 A 37 Mary St, Noosaville Qld 4566 E [email protected] recorconsulting.com