Council archive · source document
07/0387 - Op Works - Landscaping, Carparking & Access, Frontage [As Published] · 142007.387
DRAWING SIZE _ A3 Revision | Description Date
A. Re issue plans. 11.10.06.
Matt 9/06/2006 4:34 PM 16115-H1=#4.deq
First Floor
SZ
Ground Floor
SZ
General Notes :
1. Hydraulic services shown are diagramatic only. Refer to architectural
drawings for locations of fixtures.
2. All Sanitary Hydraulics and Water Reticulation within the allotment
boundary to be in accordance with AS3500.
3. All work shall comply with the requirements of authorities having
Basement Floor
WZ jurisdiction, after obtaining all necessary permits and approvals.
4, The contractor is to confirm the position of all existing services os
indicated on these ond associated plons prior to the commencing of
— work
To vented
5. Stormwater drainage pipes to 2250 shall be Class SW uPVC HEAVY
(U.N.0.) pipe. Over 2258 Concrete Rubber Ring Joint (RRU} Closs 3. All
pipes U.N.O. to be faid at a minimum grode of 1 in 100 U.N.O. Joins ore
to be constructed in accordance with the manufacturers requirements.
6. Sewers 100mm diom. uPVC DWV {U.NO.) and foid ot a minimum
grade of 1 in 60,
7. Water supply pipework below ground is to be ;
§3mm diam. or less - High Density Type 50
Class 12 Polyethylene
valve, outlet 8. All above ground ond internal water supply pipework to be Type B
to drain Line Copper . . .
f strainer FIRST FLOOR PLAN 9. Woter services are nat permitted in ground stabs and all joins and
a connections shall be made above the slab.
— Pressure limiting 10. Fire Hydrants are to be instolled are to be installed in accordance
valve. with AS2419.1. Hose Reels are to be installed in accordance with AS2441.
11. Clecn-outs, Inspection openings and Closing caps situated in
209 CW Supply vehicular or pedestrian pavements are to be fitted with either brass or
cast-iron covers.
L DISCHARGE PIPE SIZE
Isolating valve
ranch
STACK DIAGRAM
Hot water outlet
Temperature /Pressure Cold expansion
limiting valve
Hot water temperature
control d
‘acoord ASISO
200 HW
12. All in-ground valves shall be in accordance in approved concrete
200 CW Non-return rome | ON Pe es. . 4 vot . .
valve mount on wall FIXTURE 13. All waste pipes and water services penetrating slabs to be wropped
VB 40 in an approved flexible joint joint wrapping.
14, The term SERVICE’ refers to the minimum internal pipe diameter
unless noted otherwise.
Safe tray in accordance with
se “ae” Safe voy in access (@consuurina. ' regtechnical EN)
wosle As] strucluval = civil - geotechnical Se)
HOT WATER UNIT DETAIL ol 40 098 481 899 g —
(AS3500.4)
18 DUKE STREET SUNSHINE BEACH QLD.4567
LEGEND KEY c_ ~ Water Meter. Ph (07) 5447 5544 Fax (07) 5447 2634
~ UPVC Sewer, size grade and invert cmcmcwx «- Stormwater pipe, size, grade and invert a
B Bath HCB House Connection Branch NRV Non-Return Valve 1G Test Gate level as noted levels os noted Title: Internal Hydraulics Arrangement
CO Clean—Out HR 36m Fire Hose Reel ORG Overflow Relief Gully V Vent —w— - External Poly Water Service, size os noted Ne ~ Cold and Hot Water riser -
DP Rainwater Down-Pipe HWU Hot Water Unit PLV Pressure Limiting Valve VB Vanity Basin riser locations and size. Project Lot 161 Orealla Cres
FP Frog Flap IC Inspection Chamber SC Stop Cock VC Vent Cow! —CW— - internal Cold Water service Qe - Sanitary Stock number and Vent size | Sunrise Beach
FWG Floor Waste Gully 10 Inspection Opening SHR Shower WC Water Closet g Re
HC Hose Cock Loundry Tub SK Sink WM = Washing Machine | —HW— = Internal Hot Water service —@) - Fixture Unit toading. : Date: May 2006 Drg No. 16115-H1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0387 - Op Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.