Revision | Description Date
A. | Re issue plans. 41.10.06.
watt 9/06/2008 4.34 PU 18115—H1-H4.dwo
General Notes :
1. Hydraulic services shown cre diagramatic only. Refer to architectural
drawings for locations of fixtures.
2. All Sanitary Hydraulics and Water Reticulation within the allotment
boundary to be in accordance with AS3500.
3, All work shall comply with the requirements of authorities having
jurisdiction, ofter obtaining all necessary permits and approvals.
4. The coniractor is to confirm the position of all existing services as
indicated on these and ossociated plans prior to the commencing of
work,
5, Stormwater drainage pipes to 225@ shall be Class SW uPVC HEAVY
(U.N.0.) pipe. Over 2256 Concrete Rubber Ring Joint (RRU} Class 3. All
pipes U.N.0. to be laid at a minimum grade of 1 in 100 U.N.O. Joins ore
to be constructed in accordance with the manufacturers requirements.
6. Sewers 100mm diam. uPVC DWV (U.N.0.) ond laid at o minimum
grade of 1 in 60.
7. Water supply pipework below ground is to be ;
63mm diam. or less - High Density Type 50
Class 12 Polyethylene
8. All cbove ground and internal water supply pipework to be Type B
Copper.
9. Water services ore not permitted in ground slabs and all joins and
connections shall be made above the slab.
10. Fire Hydrants ore to be installed are to be installed in accordance
with AS2419.1, Hose Reels are to be installed in accordance with AS2441.
li. Cleon-outs, inspection openings ond Closing cops situated in
vehicular or pedestrion pavements are to be fitted with either brass or
cast-iron covers.
12. All in-ground valves shalt be in accordance in approved concrete
path boxes.
13. All waste pipes ond water services penetrating slabs to be wrapped
in an approved flexible joint joint wrapping.
14. The term "SERVICE’ refers to the minimum internal pipe diameter
GROUND FLOOR PLAN unless noted otherwise.
77
a0 (CONSULTING | ENGINEERS ax
SCG structural - civil - geotechaical eS
ABN 40 096 481 899
‘@
18 DUKE STREET SUNSHINE BEACH QLD.4567
LEGEND Key
Ca - Woter Meter. Ph (07) 5447 5544 Fax (07) 5447 2634
— UPVC Sewer, size grade ond invert smc «=~ Stormwater pipe, size, grade and invert a ,
B Bath HCB House Connection Branch NRV Non-Return Voive IG Test Gate level as noted ty levels as noted Title: internal Hydraulics Arrangement
CO Clean-Out HR 36m Fire Hose Reel ORG Overflow Relief Gully V = Vent —w— _ - External Poly Water Service, size as noted - Cotd and Hot Woter riser -
DP Reinwater Down-Pipe HWU Hot Water Unit PLV Pressure Limiting Valve VB Vanity Basin * riser locations and size. Project Lot 161 Oreatla Cres
FP Frog Flap IC Inspection Chamber SC Stop Cock VC Vent Cow! —CW— - Internal Cold Water service eB - Sanitary Stack number ond Vent size | Sunrise Beach
FWG Floor Waste Gully 10 Inspection Opening SHR Shower WC Woter Closet 8
HC Hose Cock Loundry Tub SK Sink WM = Washing Machine | —HW—- - Internal Hot Water service —@) - Fixture Unit loading. : Date: May 2006 Drg No. 16115-H2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0387 - Op Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.