07/0387 - Op Works - Landscaping, Carparking & Access, Frontage [As Published] · 142007.387

of 62

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

DRAWING SIZE - A2

1. Do noi scole from this drowing.

2. All dimensions in mitimeires

3, Selting out dimensions ore to be obtoined from the architectural
drawings.

4. Any discrepancies between these drawing ond the architectural drawings
are to be referred to the engineer immediately.

5. The builder is responsibie for tocoting oll existing services within and
adjacent the allotment ond shall ensure that ali new works ore in
accordence with the otteched critical depth line diagram,

6. This drawing is to be read in conjunction with the specifications ond
requirements of SCG Consulting Engineers site investigation report.
(No.16115{S)}

7. Protection against sub-terrainian termites is to be in accordance with
the architects details.

8, Al excavations are to remain dry and {ree of all loose material prior to
the placement of concrete.

1. All workmonship and materials shod comply with AS3600 - Concrete
Structures

2. Additives including FLY ASH con only be odded to the concrete upon the
approval of the engineer.

3. All concrete shod be normal class concrete unless noted otherwise.
Concrete grades, maximum slumps and moximum aggregate size are os
follows;

Foolings - 20MPo, max slump 100mm & 20mm max. agg. size.

Ground Floor Slabs 100Thk. - 25MPo, max. slump 80mm & 20mm max.
agg, size.

Members >100Thk - 40MPo, mox skimp, 80mm & 20mm mox. agg. size..
Btockwork Grout - N20, mox. slump, 100mm dé 10mm max. agg. size.

4. MI concrete members greater thon 100mm in thickness must be
mechanically vibrated.

5. in na instance shall the concrete be WETTED UP prio to or during
Placement.

6. Slob concrete shall be cured for o minimum of seven (7) days by on
approved method. Details avaiable upon request.

7. Formwork stripping ond back-propping of suspended floor slobs to the
approval of the engineer.

1. The following morks ore used to identify the vorious reinforcing steets
used, governing stondord for use also listed;
TM — Trench Mesh, min 450MPa (ASt304)
F -~ Wesh/Fobric, min. 450MPa (AS1304)
N - Deformed bar, min. 500MPo (AS1302}
R ~ Plain bor, min 250MPo (AS1302)
W = hord drown wire, min 450MPo (AS1303)
2. All reinforcement sholl de chaired, tied ond restrained in the correct
Jocotion to ensure no movernent during concrete placement. Siob mesh
chows ot 800mm ctrs, max. in both dwections.
3. Minimum cover to reinforcement is os follows:
Footings & Piers - 40mm all faces
Slabs on ground - 30mm lop {internal surfoces)
JOmm bottom {over poly. DPM)
40mm (exposed surfaces).
Suspended Slobs - 30mm {intemal surfaces),
- 40mm (exposed surfaces).
Beoms & Columns- 40mm (exposed surfaces).
- 3mm (internal surfaces).
4, Minimum ‘ap lengths ore 225mm (one pone! plus 25mm) for slob mesh,
500mm for trench mesh ond 40 times the bar diometer or 500mm
whichever greater for reinforcing bars.

TMEER :

1. All workmanship and materials shall be in accordence with AS1720 ond
AS1684.

2. All timber froming and minimum sizes unless indicated on these drowings
sholl be in accordonce with N3 Timber Froming Monwol.

3. MI timber unless noted otherwise shail be seasoned.

4, MI timber stored on site shal be stacked clear of the ground ond shall
be protected from the weather.

§. All batted connections shall be fitted with galvanized mid steel woshers.
6. Temporary brocing and support is to be provided throughout the
construction period until such stoge thot all members are installed and
connected in accordance with details provided.

7. All timber shat be appropriately protected from insect and/or moisture
attock ot least lo ihe provision of the buiding code of Australia ond
AS36680 - Protection from Sub~Tesroneon Termites.

& Pre=fobricated roof trusses are to be designed ond monufactured by o
speciofist contractor, Trusses 1o be braced in accordance with the
manufacturers requirements.

9. Floor joists exceeding 150mm in depth shall have solid blocking along the
ine of oll supporis ond at mid span for all spons exceeding 3.0m ond at
1/3 points for spons exceeding 4.2m.

10. All froming anchors, fixing plates, nailing plates, joisl hongers to be
galvanised minimum or stainless stee? where construction within 2.0 km
radius of open coastd oreos.

11, Gang-nailed splice plaies not permitted for exterior timber beams.

STEEL WORK :

1, All workmanship shail be in accordance with AS4)00 with all members and
sections being new and free of rust ond damage. Any vorialion to this must
be confirmed in writing by the engineer prior to any work commencing.

2. All steelwork unless noted otherwise shall cleaned of rust ond mil scole
ond cooted with one coat of ROZP.

3. Exposed steelwork including botts should be hot dipped galvanized in
accordance with AS4791/2 os opplicable.

4. All bolts shall be in accordance with ASIti1. Uniess noted othernise all
bolts shall be grade 4.65 (S-snug tight) galvanized. Temporary bracing and
support shall be provided until oll bolts are nstafed and {ensioned.

5, All SHS, RKS and CHS sections to be of minimum strength grade C350 in
accordance with ASI63.

6. All welding shall be carried oul by o specialist tradesmen in workshop
condilions in cecordance with AS2747. On-site welding Is ondy permitted
following prior opprowal from the engineer. Undess noted otherwise oll welds
ore to be 5.0mm continuous fillet wetds (C.F.W.).

7. The engineer is lo be privided with steelwork shop drawings for approval
prior to fabrication,

1. All materials ond workmanship to be in accordance with ASI700 1998.
2. Minimum masonry strength fuc=tSlpo

3. Mortar mix 1: 1/2 : 5 (cement:fime: sand)

4. All cores to be cleaned ond free of all mortar fins prior to grouting vin
cleon-out blocks at the base of the wall.

5. Minimum Grout strengih f'c=20MPa (300kg/m3 min. cement) with o
maximum aggregate size of 10mm. Compact grout down full depth of core
with plain rod oF similar.

7, Minimum cover to reinforcing is 20mm from inside face of block. Bars to
be arranged as shown on associated details.

B. Walls to be waterproofed where indiceled on the drawings. Waterproof
membranes instolled in strict occordonce with the monutoctures
requremenis.

Matt 31/08/2006 $42 Ale W11S-N.deg

SN8 CONSTRUCTION

SCCsmi' sa "pata &

18 DUKE STREET SUNSHINE BEACH QLD.4567
Ph (07) 5447 5544 Fax (07) 5447 2634

Title: GENERAL NOTES
Project Lot 161 Orealla Cres,
Sunrise Beach.

 

| Date: May 2006 | DrgNo. 16115-N

Used in these records

About this file

File size
5.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0387 - Op Works - Landscaping, Carparking & Access, Frontage [As Published].pdf · 5.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.