Council archive · source document
07/0387 - Op Works - Landscaping, Carparking & Access, Frontage [As Published] · 142007.387
DRAWING SIZE ~ A2
4
[AH
Natural Ground (
Ni2 @ 400
Horizontal &
Vertical
ctf
Vea end
ena
Zan
‘les
= Py 400 Cog
a
H < 1500 ~ Ni2-400
a H < 2000 ~ NI6~400
a CS 3L12TM top & botio
“if R6 figs 450 ctrs
N12 Full _
length 350 M12" 400
— Bose Widti
~ |
LEGEND
RW-03 Type 3 Retaining wall, refer detods
CW Gorden Wall Footing, refer 16115-St for details
— — WT — — indicates position of approved silt retension
fence.
FALL indicates direction of fall to surface levels,
(Ht) Indicates 3000(Lt) under ground holding tonks.
FILLING NOTES:
~The site is to be scroped cleor of all organic material and debris.
~ Any fill is to be clean gronulor material (ie. sand to a clayey sand
in accordance with AS1726) be tree of any organic material and hove
a clay content of less than 12% (Plasticity Index less than 25%, Linear
shrinkage of 15%). The proposed moteriol is to be inspected by SCG
Consulting Engineers prior to its removal to ensure its compatability.
— The fil is to be ptoced and compacted in accordance with
AS3798-1996 to a level sufficient to achieve o Level 1 certification
with a minimum retotive field density of 95%. Copies of compaction
test results shall be presented to SCG Consutling Engineers for
‘approval.
~ Filling and compacting adjacent exisiting structures is to be in
strict accordonce with the ossociated details ond specifcotions.
~ Areas where existing structures or trees are removed shali be
dockfilled with the approved fil material compacted in occordance with
AS2B70-1996 to achieve a minimum relative field density of 95%.
~ Any loose or soft materiat uncovered in the site preparation sholl
be removed and replaced with the approved fil material compacted in
accordance with AS2B70-1996 to achieve a minimum relative field
density of 95%
— Site drainoge and sit protection measures must be installed prior
to construction commencing.
WHERE NO RETAINING THE GARDEN
WALL {S TO BE GROUT FILLED MTH
Ni2~1200 CIRS VERT & HORIZ.
Longitudinal bors
Revision [Descripfon SsSC~sisz”
. Storm Water & Holding tanks added.
es
14/06/2008 14:39 AM
11.40.06.
Mait 1611$-OWl.dag
PROIR 70 CONSTRUCTION ENGINEERS
INDICATES SHEET PILING, DESIGN ANO
INSTALLATION BY OTHERS. BUILDER 70 CONFIRM
EXTENT REQUIRED 10 SATISFY CRITICAL DEPTH
LINE, PROTECTION OF NEIGHBOURING STRUCTRES.
(WINIMUM VIBRATION TECHNIQUES TO BE USED.
PRE~AUGERING OR BETTER) 70 BE WITHIN
PROPERTY BOUNDARY.
(N TO CONFIRM THE
CONTAINED HERE IN.
BUILDER TO MAINTAIN STABLITY
‘OF ALL NEIGHBOURING STRUCTURES,
DRIVEWAY CROSS OVER DETALS
TO BE tN ACCORDANCE WITH
NOOSA SHIRE COUNCIL'S STD 5 1
DRAWAGS 9005 & 9019, spot
CSW ==
9 ° ° vs
APPROVED N.S.C
KERB ADAPTOR oN,
EXISTING KERB AND CHANNELL
TO BE CUT AND REMOVED
AND NEW DRIVE WAY TO BE
WSTALLED TO N.S.C STANDARDS.
IS TO REVIEW CONTOUR SERVERY
(TO BE PROVIDED) ON BOTH ALOMENTS
5
1. Existing footpaths to be saw cut prior to removal
2. Crossings are not designed for commercial vehicles
3, Concrete driveway to be 125mm thk. excluding any
finished treatments, eg. stamping
4. Concrete surface tolerance +5.0mm over 3.0m
5. Concrete N25 in accordance with AS 1379 and AS
3600
DETAILS
6. Reinforcement fobric to AS 1304, placed central slab
depth.
7. Expansion joints to be 10mm wide wet tooled with
every 2nd mesh wire cut along joint.
8. One access point permitted for each allotment.
9. For curved driveways, maximum grades apply to inside
edge of curve
10. All services to be located and protected as required
Prior to work commencing
THE CONTRACTOR IS T0 INSTALL APPROVED SLT RETENTION FENCES
a? PRIOR TO COMMENCING ANY EARTHMIORKS. THE FENCE 15 10 BE
20-AGnm AGERECATE as i * 900() GEO-FABRIC SILT CONSTRUCTED ALONG THE LOWEST BOUNDARY AND RETURNED UP SIDE
HARD STAND Y s FALL DRIVEWAY Existing timber FENCE, FIXED TO SPIKES AND POURS 1 jo StF FUL STORUIATER EMTRAPWENT SRFACE
4 ; tin — ALLOTMENT WAIST ORAL TONARDS
consmucTon LOTT, ff gh fp aap relcining wal ee INTO STABLE AND SHALL NOT ENTER MEGHBOURING ALLOTMENTS THROUGH
fog? , OF SURFACE BUMDING OR SCOUR PROTECTED DRAINS, THE
EXISTING ORIVE WAY 10 BE i FENCE MUST REMAIN JN PLACE UNTLL SUCH TIME THAT FISHED
SMASHED AND REMOVED AND i AMDSCAPING AND DRAINAGE MEASURES ARE WSTALLED
KERB AND CHANNEL TO BE
REWSTATED 1 HSC APPROVAL.
ED ¢ noe
APPROVED S.C i
KERB ADAPTOR eee
OR NO 1200(L) 50 Sq. HOWD SPIKES,
1800 ctrs DRIVE 600 INTO
g GROUND.
im wo
>
S TYPICAL SECTION ~ SILT FENCE
©
A
m7
w” a
| is footing
20-40men AGGREGATE a J. without piers 1
HARD Sta oveRAY is founded | The builder/contractor
FOR DRIVE WAYS DURING "Existing timber . above critical | shall confirm all relevant
i retoining wal This footing is depth line and’ levels prior to
Hil: founded below is unstable. | commencing works.
! critical line and is \——tine of
EXISTING KERB ANO CHANNELL : stable. — Lire
TO BE CUT AND REMOVED j proposed Pool
AND NEW ORIVE WAY TO BE; i Excavation or
INSTALLED TO N.S.C STANDARDS. i Piers supporting strip other trench.
60001 -
e °
INDICATES SHEET PILING, DESIGN AND
INSTALLATION BY OTHERS. BUILDER TO CONFIRM
EXTENT REQUIRED 10 SATISFY CRITICAL DEPTH
Dashed line indicates
Slab thickness for
felioning wal UNE, PROTECTION OF NEIGHBOURING STRUCTRES.
(MINIMUM VIBRATION TECHNIQUES TO BE USED.
PRE-AUGERING OR BETTER) TO 8E WITHIN
PROPERTY BOUNDARY LINE. EXISTING
_ ony CROSS FALL wo
sl eh oan ee
Sis 1000 midde PLAN
(Scale 1:200)
Sow cut ond Compacted on-site.
breakout BARRIER, SEM-MOUNTABLE, MOUNTABLE sand bed
back of kerb KERB & CHANNEL OR INVERT CROSSING,
(Scole 1:20)
Depth determined
footings or post pad
footings founded into
selected material and below
critical line are considered
stoble.
CRITICAL DEPTH LINE
NOTE:
THS DETAIL ALSO APPLIES TO
EXISTING FOUNDATIONS ON
NEIGHBOURING PROPERTIES. SHEET
PILING MUST BE INSTALLED WHERE
EXISTING FOOTINGS WILL BE
FOUNDED ABOVE ANY EXCAVATION
CRITICAL DEPTH LINE
Issue: CONSTRUCTION
SCO mai" “pauses ©
ABN 40 096 481 899
18 DUKE STREET SUNSHINE BEACH QLD.4567
Ph (07) 5447 5544 Fax (07) 5447 2634
Title: Operational Works Plan.
Project Lot 161 Orealla Cres
Sunrise Beach
Date: May 2006 | Drg No. 16115-OW-1|"" A
Loy back Kerb &
Chonnel to S.C
standord.
MATCH EXISTING
CROSS FALL
Extend sub-bose 150mm
passed back of kerb.
Subgrode preperation,
refer generat notes,
PAVEMENT MATERIALS
25mm Asphollic Surfacing to N.S.C specifications
150 Base course type 2.1 CBR 80
150 Sub-base course {ype 2.3 CBR 45
Sub-grode preperation in accordance with specifications /notes
LAY BACK KERB & CHANNEL
Rew, - $001.95
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0387 - Op Works - Landscaping, Carparking & Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 5.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.