Council archive · source document
07/0387 - Op Works - Landscaping, Carparking & Access, Frontage [As Published] · 142007.387
DRAWING SIZE - A2
BRACING KEY
Bracing panel length.
1.8 (PB) <—— Bracing panel type.
(PB) - 4.0mm F27 Ply fixed in accordance with the
manufacturers requements to achieve
6.0kN/m
TIMBER LINTEL SCHEDULE
UPPER FLOOR OR SINGLE STOREY
LOPENING | _Mox. Roof width supporting. _|
90 x 35 (F8)
90 x 35 (FB)
90 x 35 (F8)
90 x 70 (F8)
90 x 70 (FI?)
90 x 35 (Fa)
90 x 35 (F8)
30 x 70 (F8)
90 x 70 (F17)
120 x 70 (Ft7)
14/06/2006 11:30 Aw 1B115~S3--S0.d09
TIMBER FRAME SPECIFICATION NS
TeWeER | SiZe/oRADE | COMMENT |
Top Plate Not trenched
Studs @ 450 | 90 x 35 (FB) | 2400{H} Max.
Btm. Plaie Not trenched
Where on slob
Noggins At 100cts mox.
LOWER STOREY OF 2 - LOAD BEARING
| MEMBER | SIZE/GRADE | COMMENT
Top Plate 90 x 45 (F8 Not trenched
Studs @ 450] 90 x 35 (F8, 2700{H) Max.
Not notched
Bim. Plote | 90 x 35 (F8} | Not trenched
Noggins 90 x 35 (F8} | At 1100cts max.
NON-LOAD BEARING
| MEMBER | SIZE/GRADE | COMMENT
— Trusses ot 600 cirs. Wax.
~ Truss manufacturer 10 confirm Isitel
sizes supporling girder trusses,
— Untels noted on plan supercede those
listed above.
~ Maximum roof width token os octuol truss
top chord leng gth).
TIE-DOWN SCHEDULE
Battens - Trusses 1/Batten Screw
Truss - Top Plate 1 Looped Gi Strap
Ralter - Top Plate 1 Looped GI Strap
Top Plate - Slab M12 Rods, 1800 cirs max.
Rafter ~ Roof Beam | 2/Framing Anchors
Woll Plate - Stud Wall] 2/100mm Batten screws
Wall Plate - Block Wolll M12 Bolts, 600 cirs
Roof Beom - Posts | 2/M12 Bolts
Roof Beam - Brk Pierd 1/12 Cast-in Bolt
Posts - Bearers 2/M12 Bolts
Comments:
Batten Screw— Wo.14 Type 17 Screw, provide 43mm min.
penetration into recieving .
Maximum truss widih 6.0m
All frorning onchors ond straps io have 4/2.8mmé nails
each end.
Roof truss design, brocing ond girder truss tie-down by
truss monufacturer.
LEGEND
@ Mt2 Anchor rod from top plate to floor frome.
X Mi2 Bolt from bottom plate to floor frame.
——— Bracing panel, refer bracing key for size type
and strength.
* es) A{No.) MIO Masonry bolts from bracing wafl stud
to core filled biock wall, equally spaced up stud,
Uda +90 Grout Fited Block Walls, N12 Verticals and
Horizontals at 800 ctrs ond full perimeter of of
openings, additional verticals where noted on
pion,
{P3} 150x150 HDWO Post.
Top Plate -
Studs © 450 | 90 x 35 (F8) ~
Bim. Plate
Noggins
Lower trussed
THIS DRAWING AND ASSOCIATED DETAILS
MUST BE READ IN CONJUNCTION WITH THE
NOTES CONTAINED ON 16115-N.
Issue:
CONSTRUCTION
QA/A CONSULTING ENGINEERS
SCG sirucloral= ch - pootachncal
ABN 40 098 461 899
18 DUKE STREET SUNSHINE BEACH QLD.4567
Ph (07) 5447 5544 Fax (07) 5447 2634
Title: Second Floor Bracing Plan.
Project Lot 161 Orealla Cres
Sunrise Beach
"| Date: May 2006 DrgNo. 16115-S8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records