DRAWING SIZE - A2

BRACING KEY

Bracing panel length.
1.8 (PB) <—— Bracing panel type.

(PB) - 4.0mm F27 Ply fixed in accordance with the
manufacturers requements to achieve

6.0kN/m

TIMBER LINTEL SCHEDULE
UPPER FLOOR OR SINGLE STOREY
LOPENING | _Mox. Roof width supporting. _|

90 x 35 (F8)
90 x 35 (FB)
90 x 35 (F8)
90 x 70 (F8)
90 x 70 (FI?)

90 x 35 (Fa)
90 x 35 (F8)
30 x 70 (F8)
90 x 70 (F17)
120 x 70 (Ft7)

14/06/2006 11:30 Aw 1B115~S3--S0.d09

TIMBER FRAME SPECIFICATION NS
TeWeER | SiZe/oRADE | COMMENT |

Top Plate Not trenched

Studs @ 450 | 90 x 35 (FB) | 2400{H} Max.

Btm. Plaie Not trenched
Where on slob

Noggins At 100cts mox.

LOWER STOREY OF 2 - LOAD BEARING

| MEMBER | SIZE/GRADE | COMMENT
Top Plate 90 x 45 (F8 Not trenched
Studs @ 450] 90 x 35 (F8, 2700{H) Max.
Not notched
Bim. Plote | 90 x 35 (F8} | Not trenched

Noggins 90 x 35 (F8} | At 1100cts max.
NON-LOAD BEARING

| MEMBER | SIZE/GRADE | COMMENT

— Trusses ot 600 cirs. Wax.

~ Truss manufacturer 10 confirm Isitel
sizes supporling girder trusses,

— Untels noted on plan supercede those
listed above.

~ Maximum roof width token os octuol truss
top chord leng gth).

TIE-DOWN SCHEDULE
Battens - Trusses 1/Batten Screw
Truss - Top Plate 1 Looped Gi Strap
Ralter - Top Plate 1 Looped GI Strap
Top Plate - Slab M12 Rods, 1800 cirs max.
Rafter ~ Roof Beam | 2/Framing Anchors
Woll Plate - Stud Wall] 2/100mm Batten screws
Wall Plate - Block Wolll M12 Bolts, 600 cirs
Roof Beom - Posts | 2/M12 Bolts
Roof Beam - Brk Pierd 1/12 Cast-in Bolt
Posts - Bearers 2/M12 Bolts

Comments:

Batten Screw— Wo.14 Type 17 Screw, provide 43mm min.
penetration into recieving .

Maximum truss widih 6.0m

All frorning onchors ond straps io have 4/2.8mmé nails
each end.

Roof truss design, brocing ond girder truss tie-down by
truss monufacturer.

LEGEND

@ Mt2 Anchor rod from top plate to floor frome.
X Mi2 Bolt from bottom plate to floor frame.

——— Bracing panel, refer bracing key for size type
and strength.

* es) A{No.) MIO Masonry bolts from bracing wafl stud
to core filled biock wall, equally spaced up stud,

Uda +90 Grout Fited Block Walls, N12 Verticals and
Horizontals at 800 ctrs ond full perimeter of of
openings, additional verticals where noted on
pion,

{P3} 150x150 HDWO Post.

 

Top Plate -
Studs © 450 | 90 x 35 (F8) ~
Bim. Plate

Noggins

Lower trussed

THIS DRAWING AND ASSOCIATED DETAILS
MUST BE READ IN CONJUNCTION WITH THE
NOTES CONTAINED ON 16115-N.

Issue:

CONSTRUCTION
QA/A CONSULTING ENGINEERS
SCG sirucloral= ch - pootachncal

ABN 40 098 461 899

18 DUKE STREET SUNSHINE BEACH QLD.4567
Ph (07) 5447 5544 Fax (07) 5447 2634

Title: Second Floor Bracing Plan.
Project Lot 161 Orealla Cres
Sunrise Beach
"| Date: May 2006 DrgNo. 16115-S8

 

Used in these records

About this file

File size
5.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0387 - Op Works - Landscaping, Carparking & Access, Frontage [As Published].pdf · 5.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.