J3.4

J3.5

ASSESSMENT NO:2009/ 0919
Windows and doors
Design Review

(a) As air conditioning is to be installed, seals to restrict air infiltration must be fitted to
each edge of an external door, openable external window or the like forming part of

G) the envelope of a conditioned space; or
(ii) the external fabric of a habitable room or public area in climate zones 4, 6, 7
and 8.

(b) The requirements of (a) do not apply to —
Gi) A window complying with AS 2047; or
(ii) a louvre door, louvre window or other such opening; or
(iii) —_a fire door, or smoke door; or
(iv) roller shutter door, roller shutter grille or other security door or device
installed only for out of hours security.

(c) A seal required by (a) may be a foam or rubber compressible strip, fibrous seal or the
like.

(d) A main entrance to a building, if leading to a conditioned space, must have an
airlock, self-closing door, revolving door or the like, other than —
(i) where the conditioned space has a floor area of not more than 50m? or
(ii) where a café, restaurant, open front shop or the like has-
(A) a3m deep un-conditioned zone between the main entrance,
including an open front and the conditioned space; and
(B) all other entrances to the café, restaurant, open front shop or the like
have self-closing doors.

Result

Will comply if the above design review is satisfied.
Exhaust fans

Design Review

A miscellaneous exhaust fan, such as a bathroom or domestic kitchen exhaust fan, must be
fitted with a sealing device such as a self-closing damper or the like when serving —

(a) a conditioned space; or

(b) a habitable room in climate zones 4, 6, 7 and 8.

Result

As air conditioning is to be installed, any exhaust fan must be fitted with a sealing device
such as a self-closing damper, filter or the like.

4 Lillypilly Court, Page No. 8 Phone: (07) 493 2981
KAWANA FOREST.....4551. Fax: (07) 5493 3867

|

Used in these records

About this file

File size
4.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_1508 - Operational Works - Landscaping. Stormwater, S&E Control, Carparking & Acess, Frontage Works [As Published].pdf · 4.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.