J33 J5.4 ASSESSMENT NO: 2009/ 0919 Result Will comply if the above design review is satisfied — clarification of the above, where installed, may need to be certified by a Competent Person accepted by the Certifier. Time Switch Design Review A time switch in accordance with Specification J6 must be provided to control each of the following: (a) an air-conditioning system of more than 10kWr; (b) a ventilation system with an air flow rate of more than 1000L/s; (c) heating systems of more than 10kw (heating) Result Will comply if the above design review is satisfied — clarification of the above, where installed, may need to be certified by a Competent Person accepted by the Certifier. Heating and chilling systems Design Review (a) Systems that provide heating or cooling for air-conditioning systems must- (i) have any piping, vessels, heat exchangers or tanks containing heated or chilled fluid, other than those with insulation levels covered by Minimum Energy Performance Standards (MEPS), insulated in accordance with Specification J5.4; and (ii) where water is circulated by pumping at greater than 2L/s- (A) _ be designed so that the total of the motor shaft power to the air- conditioning pump does not exceed- (aa) 3W/m? for a building of not more than 500m? floor area; and (bb) 4W/m? for a building of more than 500m? floor area; and (B) have the pump capable of varying its speed when it is- (aa) operating for more than 3,500 hours per year; or (bb) is more than 11 kW of motor shaft power except where the pump is needed to run at full speed for safe or efficient operation; and (iii) if the system contains more than one water heater used for heating a building, chiller or coil, be capable of stopping the flow of water to those not operating. (b) A water heater such as a boiler in a heating system for a building, must achieve a thermal efficiency complying with Table J5.4a when tested in accordance with BS 7190. (c) Package air conditioning equipment, including a split unit and a heat pump, must have an energy efficiency ratio complying with Table J5.4b, when tested in accordance with AS/NZS 3823.1.2 at test condition T1. (d) A refrigerant chiller over 125 kWr capacity, must have an energy efficiency ratio complying with Table J5.4c when determined in accordance with ARI 550/590. (e) An air cooled condenser fan motor, other than one that is part of package air- conditioning equipment in (c), must not use more than 15W of motor shaft power for each kW of heat rejected from the refrigerant when determined in accordance with ADT 4cn SUN FUU. 4 Lillypilly Court, Page No. 12 Phone: (07) 5493 2981 KAWANA FOREST.....4551. Fax: (07) 5493 3867 iI
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/1508 - Operational Works - Landscaping. Stormwater, S&E Control, Carparking & Acess, Frontage Works [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.