Council archive · source document
09/1508 - Operational Works - Landscaping. Stormwater, S&E Control, Carparking & Acess, Frontage Works [As Published] · 142009.1508
(b) (c) 4 Lillypilly Court, KAWANA FOREST (vi) (vii) ASSESSMENT NO: 2009/ 0919 when the air flow rate is greater than 1000L/s, have a fan motor shaft power to air flow rate ratio, or fan motor input power to air flow rate ratio, in accordance with Table J5.2; and the requirements of (vi) do not apply to- (A) fans in a package air-conditioning plant complying with J5.4(c), and (B) __ the input power for an energy reclaiming system that preconditions outdoor air; and (C) _ the input power for process related components such as high efficiency particulate air filters. A mechanical ventilation system must- @ (ii) (iii) (iv) be capable of being inactivated when the building or part of the building served is not occupied; and when serving a conditioned space, not provide mechanical ventilation in excess of the minimum quantity required by Part F4 by more than 50% other than where there is- (A) additional unconditioned outside air supplied- (aa) _ to provide free cooling; and (bb) to balance required exhaust ventilation such as toilet exhaust; ‘and (cc) to balance process exhaust such as from a health-care building or laboratory; or (B) additional exhaust ventilation needed to balance the required mechanical ventilation; or (C) anenergy reclaiming system that preconditions outside air; and when the air flow rate is more than 1000L/s, (A) | have a fan motor shaft power to air flow rate ratio, or fan motor input power to air flow rate ratio, in accordance with Table J5.2; and (B) _ in other than climate zone 2, when serving a conditioned space in a Class 9b building where the number of square metres per person is 1 or less as specified in D1.13 have- (aa) an energy reclaiming system that preconditions outside air; or (bb) _ the ability to automatically modulate the mechanical ventilation required by Part F4 in proportion to the number of occupants. when serving over 40 vehicles in a carpark- (A) _ be controlled by an atmospheric contaminant monitoring system in accordance with AS 1668.2; and (B) —_— maintain an average nimumum air-change rate of 0.5 air changes per hour other than when the carpark is not occupied for a period of more than 2 hours. The requirements of (a) and (b) must not inhibit- (i) Gi) wee 4551, the smoke hazard management operation of air-conditioning and mechanical ventilation systems; and essential ventilation such as for a garbage room, lift motor room, gas meter enclosure or gas regulator enclosure or the like. Page No. \\ Phone: (07) 5493 2981 Fax: (07) 5493 3867
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/1508 - Operational Works - Landscaping. Stormwater, S&E Control, Carparking & Acess, Frontage Works [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.