6. Information Required.
to treat water quality for
We believed that raingardens in each lot are the only practical measure
the systems. In
these three lots given Council’s constraints on siting access and maintaining
not building new street
recent years urban OPWs for two to five lot subdivisions where we are
Treatment devices therefore it is not considered
frontage did not require Stormwater Quality
reasonable to request them for this instance.
The following alternatives have been investigated and rejected:
is not feasible to pipe water
. Due to the gully separating the road from the house sites, it
in the Wilgee street road reserve.
across the gully to a bio treatment system
. A bio device could be
below the Q 100
placedadjacent the southeast boundary of lot 5
.
however, it would have no maintenance access.
future lot 13 would be also
. A similar device in the southwest corner of lot 5 or possible
easement and track over the
impossible to access without a long temporary access
balance land. This would put an unreasonable restriction on the future options for the
the Refer to
balance land. There is also the issue of future sewers crossing
area.
attached Master Sewer Plan 1225-3008.
to the
. Lot 13 in the future development will have its roofwater and driveway discharge
the cul-de-sac head. The
street and then be treated by the bio basin proposed for beside
lots and the bio basin
remaining back will be modelled in Music with the rest of the
yard
sized to ensure that the water quality targets are met.
be no other feasible solution to
Since Council do not prefer Raingardens there appears to
site conditions and small
include Water Quality Improvement Devices. Due to the constrained
the requirement for
number of lots on an existing road frontage, we request that Council remove
Water Quality Improvement Devices on this stage.
Yours faithfully,
Callaghan & Toth
~z=5
A Haynes BE Civil (Hans)RPEQ MIEAust CPEng
and terms and conditions for services rendered
Please view www.callaghanandtoth.com.au for all information on our company profile
Cc Alex Mc Williams
Max Watterson
2 CorrespondencelREC Info request response.doc
X:\JobsICT Projects In progressl1225 30 lots lake MacDonald DrlvelCorrespondencelStage
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to information request REC13/0095Related documentApplication case desk ↗
About this file
- File size
- 46.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.