Original source · versioned page text
2019-09-30 Special Meeting Agenda - Item 1 - Attachment 4 - Court Judgement
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
MATERIALS ON-SITE DESTINATION
Re-use and Recycling Disposal
Expected waste Estimated On-site Off-site *specify contractor
materials volume(m³) *specify proposed *specify contractor and landfill site or
re-use or on-site and recycling outlet other disposal site
recycling methods
Excavation
material
Green waste
Bricks
Concrete
Timber-please
specify
Plasterboard
Metals - please
specify
Asbestos
Other - please
specify
Note * If a demolition contractor is undertaking works, then the Waste Management table is to be
completed by the demolition contractor.
Waste Storage
52. The developer must provide waste storage and disposal facilities in accordance with
Planning Scheme Policy 9, Waste Management, including an external imperviously
paved area correctly sized for all refuse and recycling containers and suitably screened
from public places and neighbouring properties.
53. A bin wash area is required with a cold-water tap, hose and drain outlet connected to
sewer, via a bucket trap. The drain outlet is to be designed to prevent storm water entry
to the sewerage system which can be achieved by a bunded area, with a nib wall height
of 100mm maximum, enclosing a wash area of 700mm x 700mm minimum (max 0.7m²).
Alternatively, the waste area can be roofed, or any other appropriate design approved
by Council.
Noise
54. Upgraded building envelope constructions and the provision of mechanical
ventilation/air conditioning which achieves the ventilation requirements of the Building
Code of Australia, in accordance with the Second Joint Report of Experts in Noise (30
May 2018) for Planning and Environment Court Appeal 4066 of 2017, including:
(a) the facades of the Visitor accommodation Type 4 motel building facing towards
the IGA building and IGA carparking area;
(b) the facades of the Visitor accommodation Type 4 dwelling units facing towards the
IGA building; and
(c) the facades of the Visitor accommodation Type 4 dwelling units facing towards the
hotel building, drive-through access road and drive-through bottleshop, and
carparking areas.
55. Prior to the commencement of use written certification is required from a suitably
qualified person confirming that upgrades to the building facades and provision of
mechanical ventilation/air conditioning comply with the recommendations of the Second
Joint Report of Experts in Noise (30 May 2018) for Planning and Environment Court
Appeal 4066 of 2017.
Document Set ID: 20933247
Version: 1, Version Date: 16/07/2019
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.