Original source · versioned page text
Nandroya Planning Report
Attached to the e-mail MCU16/0066_Further info re: Representations regarding stormwater 6 Taylor Court Cooroy.msg.
leddy sergiacomi & associates pty. itd. LSA Ref: 45-021 It is noted that an industrial peak hour demand is unlikely to coincide with a residential peak hour demand. On the basis of the WSA Guidelines, a peak day (maximum day) demand for the estate is calculated as follows: 10.67ha x 0.25 litres/second/ha x 3600 x 24hrs x 2 (PDF) = 460,944 litres/day Peak Hour Demand = average hour demand on peak day x peak hour factor (PHF) = 10.67ha x 0.25 litres/second/ha x 3600 x 5 (PHF) = 96,030 litres/hour, or 26.67 litres/second. Consideration of Council’s water supply headworks calculations indicates that Council has assumed a demand rate of 3.6 ep/1,000m2, equating to 106,700 square metres/1,000 x 3.6 = 384.12 ep. Assuming a flow rate of 500 litres per equivalent person, this equates to a daily demand of 192,060 litres using the rationale in Council’s PSP28. Using a coefficient of 2.25 for calculating maximum day (refer Water Resource Commission Guidelines for Water Supply Systems which was operational around the time the headworks policy came into effect), a flow of 432,135 litres/day can be assumed. Peak hourly demand can be calculating by doubling the average hour, equating to 36,011 litres/hour. This equates to a flow of around 10 litres/second. Given the above outcomes, the flows derived from the WSA Guidelines have been considered to be less applicable to the site than those used to calculate Council’s water supply headworks. The WSA Guidelines are primarily used to size a water distribution system upstream of the balancing storage. To this end, the following calculations have been adopted for determining water supply requirements for the proposed six lot subdivision at Cooroy in accordance with Council’s policy for water supply headworks: Peak Daily Flow (Maximum Day) = 432,135 litres/day Peak Hourly Demand (Max Day/12hrs) = 36,011 litres/hour Peak Instantaneous Demand (PHD/3,600) = 10.0 litres/second 14 November 2005 Department of State Development, Trade and Innovation Page: 36 Planning Report
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.