Amended plans
Attached to the e-mail MCU22/0207 & OPW22/0314 - Response to Council’s Information Request - 24 Wesley Court Noosa Heads.
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES
lot 45 on N21844
24 wesley court, noosa heads 4567 TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
UPPER FLOOR TOP PLATE
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
UPPER FLOOR JOINERY LINE
ACCORDANCE WITH AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
2400
2100
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
UPPER FLOOR
9. BUILDER AND TRADES ARE TO CONFIRM ALL
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
GROUND FLOOR TOP PLATE
SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
GROUND FLOOR JOINERY LINE AS NO RESPONSIBILITY WILL BE TAKEN AFTER
2540
2400
provide CONSTRUCTION HAS COMMENCED
screening 11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
GROUND FLOOR HER OWN WORK
530
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
PAD LEVEL 3660.1.2000
DOMESTIC SMOKE ALARMS
extend wall deck extension proposed jetty
propose pergola + roof over 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
elevation A WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
3. DEVICES MUST BE INTERCONNECTED AND HARD
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
PRIVACY OPTIONS
ELECTRICAL AND ENERGY EFFICIENCY
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
existing
boundary line
outdoor DOWNPIPES
existing tree to be shower ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
removed CONFIRMED AT TIME OF ROOFING CONSTRUCTION
existing elevations
AND COMPLIANCE
existing residence
elevation B extend wall + relocated/
reconstruct stairs
700 elevation D
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: CATHERINE + BUILDER: NOOSA'S OWN BUILDING MANDY'S DRAFTING ONLY SHEET: 3 of 7 DATE: ISSUE NO:
EXTENSION + JETTY ROBERT MARTYR + MAINTENANCE PH: 5474 1906 QBCC:1254229 PH: 0403 481 474 SCALE: 1:100 16 FEB 2023 CR-2023-K
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH