Amended plans
Attached to the e-mail MCU22/0207 & OPW22/0314 - Response to Council’s Information Request - 24 Wesley Court Noosa Heads.
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES
lot 45 on N21844
24 wesley court, noosa heads 4567 TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
Elevation 1 - south
06 of 07
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
3 boundary line
GRADE F14 & MINIMUM JOINT GROUP J2.
05 of 07 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
Elevation 3 - east
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
3000
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
10000
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
propose bollard lights handrail as required (type to be confirmed by owner) BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
type to be confirmed + as per aus standards 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
boundary line/revetment wall
9. BUILDER AND TRADES ARE TO CONFIRM ALL
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
1500
4 4 SETOUT AND ORDERING OF MATERIALS
19.5m2 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
3000
AS NO RESPONSIBILITY WILL BE TAKEN AFTER
CONSTRUCTION HAS COMMENCED
3000 7000 11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
800
100x100 shs post HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
3660.1.2000
1290
existing doors
DOMESTIC SMOKE ALARMS
DN 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
1290
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
REGULATION 2016
1 1
frame
5345 extension
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
5660
aluminium pergola 5675
5770
deck extension
aluminium framed pergola WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
6595
+ tinted glass sheets over AND INTERCOM SYSTEMS.
1290
in line with existing floor 3. DEVICES MUST BE INTERCONNECTED AND HARD
over WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
decking
REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
1290
BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
9900
GLAZING
5465 aluminium portal
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
existing
existing line of floor over
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
residence 3070 950
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
glass balustrading
4550 existing
aluminium framed sliding gates under
PRIVACY OPTIONS
existing
ELECTRICAL AND ENERGY EFFICIENCY
2 2
4550
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
2325 INDICATIVE ONLY
530 DOWNPIPES
bbq bench ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
DN
350
CONFIRMED AT TIME OF ROOFING CONSTRUCTION
AND COMPLIANCE
1160
proposed aluminium
boundary line
existing concrete path angle blade screen
proposed floor
existing fence
Elevation 2 - west
3
05 of 07
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: CATHERINE + BUILDER: NOOSA'S OWN BUILDING MANDY'S DRAFTING ONLY SHEET: 4 of 7 DATE: ISSUE NO:
EXTENSION + JETTY ROBERT MARTYR + MAINTENANCE PH: 5474 1906 QBCC:1254229 PH: 0403 481 474 SCALE: 1:100 16 FEB 2023 CR-2023-K
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH