GENERAL NOTES
lot 45 on N21844
24 wesley court, noosa heads 4567 TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
proposed structural aluminium MGP 10/MGP12
powder coated pergola 4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
proposed powdercoated aluminium 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
framed structure + tinted glass over painted black 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
100x100 shs post
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
AS NO RESPONSIBILITY WILL BE TAKEN AFTER
aluminium angle blade CONSTRUCTION HAS COMMENCED
overall height pergola
screen 11. ALL TRADES ARE TO CONFORM WITH THE
5665
2540
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
HER OWN WORK
3790
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
ht to be confirmed 3660.1.2000
DOMESTIC SMOKE ALARMS
800
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
aluminium framed sliding gates under for storage REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
vertical aluminium framed sliding gate proposed jetty WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
Elevation 1 - south 3. DEVICES MUST BE INTERCONNECTED AND HARD
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
boundary line
PRIVACY OPTIONS
ELECTRICAL AND ENERGY EFFICIENCY
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
proposed pergola feature
existing DOWNPIPES
(structural aluminium portals)
outdoor
proposed elevations
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
shower
3790
overall height pergola from ngl CONFIRMED AT TIME OF ROOFING CONSTRUCTION
AND COMPLIANCE
530
line of fence
light bollards proposed jetty
Elevation 2 - west proposed wall extension + vertical
propose stairs
relocated from existing
cladding over to match existing
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: CATHERINE + BUILDER: NOOSA'S OWN BUILDING MANDY'S DRAFTING ONLY SHEET: 5 of 7 DATE: ISSUE NO:
EXTENSION + JETTY ROBERT MARTYR + MAINTENANCE PH: 5474 1906 QBCC:1254229 PH: 0403 481 474 SCALE: 1:100 16 FEB 2023 CR-2023-K
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH