Council archive · source document
Decision Notice - 010.2008.00000255.001 [As Published] · 132008.255
2008/255
DA-102 E First Floor Plan – Willis Greenhalgh Architects 08.07.08
DA-103 D Roof Plan – Willis Greenhalgh Architects 08.07.08
DA-104 E North Elevation – Willis Greenhalgh Architects 08.07.08
DA-105 E East Elevation – Willis Greenhalgh Architects 08.07.08
DA-106 F South Elevation – Willis Greenhalgh Architects 08.07.08
DA-107 H West Elevation – Willis Greenhalgh Architects 04.08.08
DA-108 E Section A-A – Willis Greenhalgh Architects 08.07.08
DA-109 E Sections B & C – Willis Greenhalgh Architects 04.08.08
and as may be amended by these conditions and annotations on the plans.
2. The dwelling shall have a maximum height of two storeys and a maximum height of 8 metres
above the natural and finished ground levels pursuant to The Noosa Plan. In this regard the
natural ground shall be reinstated around the lower ground floor so as not to constitute a
storey as defined by The Noosa Plan.
3. A verification survey of the building is to be carried out by a Licensed Surveyor and a
certificate lodged with Council at completion of work confirming compliance with the maximum
allowable building height as required by either the conditions of approval or the Planning
Scheme.
4. The garage and manoeuvring area shall be constructed at a level that permits the area to
drain from the site by gravity means without the need for mechanical pumping, alternatively an
onsite infiltration system installed that shall not adversely affect neighbouring properties.
5. Security in the form of a cash bond or trading bank guarantee to the sum of $1500 must be
submitted, to secure performance of all conditions of this approval, prior to the issue of a
Development Permit for building works. The cash bond or trading bank guarantee will be
returned on performance of the conditions of approval less any costs incurred by Council in
respect of enforcing performance of this permit.
6. The development must be undertaken and operated in a manner that causes no detrimental
effect upon the amenity of the neighbourhood by reason of the creation of excessive noise,
lighting nuisance or other emissions.
7. The proposed development shall have all kitchen, laundry and bathroom fittings that comply
with the AAA Water Conservation Rating System as defined by the AS/NZS 6400 (Water
Efficient Products - Rating and Labelling 2003) and AS/NZS 3500 (National Plumbing and
Drainage Standard Part 1.2), with toilets to comply with the AAAA Water Conservation Rating
System. All tap ware and shower roses shall not exceed a maximum flow of 9 litres per min.
Dishwashers and washing machines are excluded from this requirement.
8. A rainwater storage tank with a minimum capacity of 5000 litres shall be provided on site to
service the detached house. The tank is to be installed to ensure water from the tank can be
used both:
8.1. For external use such as watering gardens, irrigation, ornamental ponds or water
features, topping up swimming pools, outdoor cleaning; and
8.2. For use in flushing of toilets internal to the building.
9. All hot water systems installed shall be either solar systems; electric heat pump systems; or
gas systems (LPG or natural).
Page 2 of 8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - 010.2008.00000255.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 59 KB (small file)
- File type
No other editions are linked here.